Preferred Language
Articles
/
oBctno0BVTCNdQwCvhYi
The efficacy of polyether‐ether‐ketone wire as a retainer following orthodontic treatment
...Show More Authors
Abstract<sec><title>Objectives

To investigate the efficacy of polyether‐ether‐ketone (PEEK) wire as a fixed orthodontic retainer, by comparing its performance to other retainer wires and optimizing its adhesion to composite bonding materials.

Materials and methods

Retainer wires of 15 mm segments were used, PEEK wires were prepared in cylindrical form with 0.8 mm diameter, and had two surface treatments namely air‐abrasion and conditioning with adhesive system. Three different metallic retainer wires were used for comparison and three tests were performed; two tests measured debonding force and associated wire deflection from acrylic blocks and bovine teeth and one test for pull‐out force. To test debonding force, a vertically directed compressive force was applied to the retainer wires bonded to the acrylic blocks and bovine teeth, while for pull‐out test; a vertically directed tensile force detached the retainer wire.

Results

In both debonding tests, PEEK wires (regardless the surface treatment) had non‐significant difference when compared to each other, or to the other metallic wires, except the dead‐soft coaxial wire group. The dead‐soft coaxial wire group had significant difference when compared to other groups regarding both the force magnitude and maximum deflection, the only exception was the debonding force of the flat braided retainer wires bonded to bovine teeth. In pull‐out test PEEK wires conditioned with adhesive system and the air‐abraded recorded the second and third highest readings respectively.

Conclusions

Within the limitations of this study, the 0.8 mm round PEEK wires have comparable performance—in terms of debonding and pull out forces—to conventional retainers when bonded with 4 mm composite bonding spots; using air‐abrasion for 10 s at 3.5 MPa provided sufficient adhesion of the composite to the wire, and conditioning with adhesive system may provide no further clinical benefit.

Scopus Clarivate Crossref
View Publication
Publication Date
Fri Sep 24 2021
Journal Name
Applied Sciences
The Impact of Calcitriol on Orthodontic Tooth Movement: A Cumulative Systematic Review and Meta-Analysis
...Show More Authors

A cumulative review with a systematic approach aimed to provide a comparison of studies’ investigating the possible impact of the active form of vitamin D3, calcitriol (CTL), on the tooth movement caused by orthodontic forces (OTM) by evaluating the quality of evidence, based on collating current data from animal model studies, in vivo cell culture studies, and human clinical trials. Methods: A strict systematic review protocol was applied following the application of the International Prospective Register of Systematic Reviews (PROSPERO). A structured search strategy, including main keywords, was defined during detailed search with the application of electronic database systems: Medline/Pubmed, EMBASE, Scopus, Web of Science, and

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sat Sep 26 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Root resorption and anti-dentine antibody level in serum and saliva of well-controlled type ? diabetic patients undergoing orthodontic treatment
...Show More Authors

Background: Diabetic mellitus type ? is a metabolic disorder of diverse etiological factors, characterized by hyperglycemia resulting from an absolute deficiency of insulin affected childhood and adolescent. Some of these patients seek an orthodontic care .The orthodontist who is treating these medically compromised patients should have a working knowledge of the multitude of medically complex problems. This information will support and enable for delivery of high standards of dental care in general and orthodontic care in particular. The aim of this study was to analyze serum IgG levels and salivary secretory IgA (sIgA) levels in human dentine extract (HDE) before (T0) and 6 months after (T6) orthodontic treatment and to correlate anti-HDE

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2015
Journal Name
Conference: 8th International Conference And Exhibition On Design And Production Of Machines And Dies/molds
Design, Construction, and Controlling of A Shaped Metal Deposition Machine Using Arc Metal-Wire System
...Show More Authors

Publication Date
Fri Feb 01 2019
Journal Name
Environmental Technology & Innovation
Cadmium removal using a spiral-wound woven wire meshes packed bed rotating cylinder electrode
...Show More Authors

The effect of electrolysis operating parameters on the removal efficiency of cadmium from a simulated wastewater was studied by adopting response surface methodology combined with Box–Behnken Design. As a new electrode design, spiral-wound woven wire mesh rotating cylinder electrode was used for cadmium removal. Current (240–400 mA), rotation speed (200–1000 rpm), initial cadmium concentration (200–600ppm), and cathode mesh number (30–60) were chosen as independent variables while the removal efficiency of cadmium was considered as a response function. The results revealed that the rotation speed has the major effect on the removal efficiency of cadmium. Regression analysis showed good fit of the experimental data to the second-or

... Show More
View Publication Preview PDF
Scopus (29)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Environmental Technology &amp; Innovation
Cadmium removal using a spiral-wound woven wire meshes packed bed rotating cylinder electrode
...Show More Authors

View Publication
Scopus (29)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Sun Jan 19 2020
Journal Name
Biochemical And Cellular Archives
Isolation and characterization of phosphate solubilizing Pseudomonas species and assess its efficacy as plant growth promoter
...Show More Authors

Preview PDF
Scopus (2)
Scopus
Publication Date
Sat Jun 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Validity of digital interceptive orthodontic/therapeutic protocols post global pandemics: A review
...Show More Authors

Background: Aggressive global pandemics such as COVID-19 can disrupt societies tragically, imposing a suspension to almost every field throughout the world; the orthodontic treatment and follow-up is no exemption. Objectives: To provide practical recommendations about resuming treatment for orthodontic patients during the “Return-to-Practice” phase and emphasize the validity of certain digital interceptive measures post global pandemics to minify the risk of infection spread. Materials and Methods: Sources of information pertaining to orthodontic/therapeutic implications during the COVID-19 pandemic were searched using electronic databases including COVID-19 Open Research Dataset (CORD-19 2020), Google Scholar, Scopus, PubMed, M

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Dec 07 2014
Journal Name
Baghdad Science Journal
Study the Changes of Thyroid Hormones Levels Following Major Urological Surgery
...Show More Authors

This study was designed to evaluate the effect of major surgery on thyroid hormones and thyrotropin in patient undergoing major lower abdominal surgery. The study included fifty patients scheduled for elective major lower abdominal surgery, the serum levels of T3, T4 and TSH were determined one day preoperatively, intraoperative, one day postoperatively, two days postoperatively, and rT3 was determined one day preoperatively, and one day postoperatively. We observed that the levels of (T3, T4, TSH) increased significantly (P<0.05) intraoperatively, one day postoperatively the levels of T3 and T4 reduced significantly (P<0.05), while TSH reduced not significantly (P>0.05), and two days postoperatively T4 and TSH returned to increase si

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 02 2022
Journal Name
Journal Of Medicinal And Chemical Sciences
Microwave synthesis schiff Base from Drug and 1,10-phenanthroline/8_Hydroxy quinoline as a Co- ligand with complexes:cytotoxic, Antimicrobial, and DNA Interaction Efficacy
...Show More Authors

Publication Date
Sat Sep 26 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Tensile force measurement by using different lingual retainer wires, bonding materials types and thickness (A comparative in vitro study)
...Show More Authors

Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H O

... Show More
View Publication Preview PDF