Preferred Language
Articles
/
oBctno0BVTCNdQwCvhYi
The efficacy of polyether‐ether‐ketone wire as a retainer following orthodontic treatment
...Show More Authors
Abstract<sec><title>Objectives

To investigate the efficacy of polyether‐ether‐ketone (PEEK) wire as a fixed orthodontic retainer, by comparing its performance to other retainer wires and optimizing its adhesion to composite bonding materials.

Materials and methods

Retainer wires of 15 mm segments were used, PEEK wires were prepared in cylindrical form with 0.8 mm diameter, and had two surface treatments namely air‐abrasion and conditioning with adhesive system. Three different metallic retainer wires were used for comparison and three tests were performed; two tests measured debonding force and associated wire deflection from acrylic blocks and bovine teeth and one test for pull‐out force. To test debonding force, a vertically directed compressive force was applied to the retainer wires bonded to the acrylic blocks and bovine teeth, while for pull‐out test; a vertically directed tensile force detached the retainer wire.

Results

In both debonding tests, PEEK wires (regardless the surface treatment) had non‐significant difference when compared to each other, or to the other metallic wires, except the dead‐soft coaxial wire group. The dead‐soft coaxial wire group had significant difference when compared to other groups regarding both the force magnitude and maximum deflection, the only exception was the debonding force of the flat braided retainer wires bonded to bovine teeth. In pull‐out test PEEK wires conditioned with adhesive system and the air‐abraded recorded the second and third highest readings respectively.

Conclusions

Within the limitations of this study, the 0.8 mm round PEEK wires have comparable performance—in terms of debonding and pull out forces—to conventional retainers when bonded with 4 mm composite bonding spots; using air‐abrasion for 10 s at 3.5 MPa provided sufficient adhesion of the composite to the wire, and conditioning with adhesive system may provide no further clinical benefit.

Scopus Clarivate Crossref
View Publication
Publication Date
Sat Aug 01 2020
Journal Name
Key Engineering Materials
Compressive Strength Performance of Reactive Powder Concrete Using Different Types of Materials as a Partial Replacement of Fine Aggregate
...Show More Authors

Reactive Powder Concrete (RPC) can be incorporate as a one of the most important and progressive concrete technology. It is a special type of ultra-high strength concrete (UHSC) that’s exclude the coarse aggregate from its constitutive materials. In this research an experimental study had been carried out to investigate the effect of using three types of materials (porcelain aggregate) and others sustainable materials (glass waste and granular activated carbon) as a partial replacement of fine aggregate. Four percentages had considered (0, 10, 15 and 20) % to achieve better understanding for the influence of these materials upon the compressive strength of RPC. Four curing ages had included in this study, these are; 7, 28, 60 and

... Show More
Scopus (5)
Crossref (7)
Scopus Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Key Engineering Materials
Compressive Strength Performance of Reactive Powder Concrete Using Different Types of Materials as a Partial Replacement of Fine Aggregate
...Show More Authors

Reactive Powder Concrete (RPC) can be incorporate as a one of the most important and progressive concrete technology. It is a special type of ultra-high strength concrete (UHSC) that’s exclude the coarse aggregate from its constitutive materials. In this research an experimental study had been carried out to investigate the effect of using three types of materials (porcelain aggregate) and others sustainable materials (glass waste and granular activated carbon) as a partial replacement of fine aggregate. Four percentages had considered (0, 10, 15 and 20) % to achieve better understanding for the influence of these materials upon the compressive strength of RPC. Four curing ages had included in this study, these are; 7, 28, 60 and

... Show More
View Publication
Crossref (7)
Crossref
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Determining the Optimal Ratio of Liquidity in Iraqi Commercial Banks for period (2005-2013): applied research using Iraqi Commercial Banks as a sample study
...Show More Authors

  This study  focused on a fundamental issue which was represented by ability of Iraqi central bank in facing the difficulty of determining  the optimal ratio of liquidity in the Iraqi banks in terms of the balancing between its obligations to the depositors and borrowers, and liquidate their funds on one hand and the risks on the other hand.the search aimed  for achieving the goals which represented by identifying the possibility of Iraqi banks to apply the regulations rules and  instructions  issued by central bank  of  Iraq in determining  ratio  of  liquidity and  its  appropriate with Iraqi  banks  action to implement  a  reasonable  profit to&

... Show More
View Publication
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Siriraj Medical Journal
The Potential of Vitamin-D-Binding Protein as a Urinary Biomarker to Distinguish Steroid-Resistant from Steroid-Sensitive Idiopathic Nephrotic Syndrome in Iraqi Children
...Show More Authors

Objective: To determine the ability of uVDBP to discern SRNS from steroid-sensitive nephrotic syndrome (SSNS) in Iraqi children. Materials and Methods: This cross-sectional study enrolled children with SRNS (n=31) and SSNS (n=32) from the pediatric nephrology clinic of Babylon Hospital for Maternity and Pediatrics over three months. Patients' characteristics in terms of demographics, clinical data, and urinary investigations were collected. Quantitative analysis of uVDBP levels was undertaken via a commercially available ELISA kit. Results: The median uVDBP values were significantly higher (p-value<0.001) in the SRNS group (median=10.26, IQR=5.91 μg/mL) than in the SSNS group (median=0.953, IQR=4.12 μg/mL). A negative correlati

... Show More
View Publication
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Wed Mar 01 2000
Journal Name
Al-rafidain Collage Conference
The Modification of Median Filter to use as noise reduction procedure
...Show More Authors

Publication Date
Sun Jul 17 2016
Journal Name
2016 Asabe International Meeting
THE PERFORMANCE OF FARM TRACTORS AS REPORTED BY CAN-BUS MESSAGES
...Show More Authors

View Publication
Scopus (16)
Crossref (2)
Scopus Crossref
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
Effect of Magnetic Water Treatment on Prevention of CaCO3 Scales
...Show More Authors

Permanent magnets of different intensities were used to investigate the effect of a magnetic field in the process of preventing deposits of calcium carbonate. The magnets were fixed on the water line from the tap outside. Then heating a sample of this water in flasks and measuring the amount of sediment in a manner weighted differences. These experiments comprise to the change of the velocity of water flow, which amounted to (0.5, 0.75, 1) m/sec through the magnetic fields that are of magnetic strength (2200, 6000, 9250, 11000) Gauss, and conduct measurements, tests and compare them with those obtained from the use of ordinary water.The results showed the effectiveness of magnetic treatment in reducing the rate of deposition of calcium carb

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Journal Of Engineering
Electrocoagulation for Treatment of Simulated Blowdown Water Of Cooling Tower
...Show More Authors

This study investigates the results of electrocoagulation (EC) using aluminum (Al) electrodes as anode and stainless steel (grade 316) as a cathode for removing silica, calcium, and magnesium ions from simulated cooling tower blowdown waters. The simulated water contains (50 mg/l silica, 508 mg/l calcium, and 292 mg/l magnesium). The influence of different experimental parameters, such as current density (0.5, 1, and 2 mA/cm2), initial pH(5,7, and 10), the temperature of the simulated solution(250C and 35 0C), and electrolysis time was studied. The highest removal efficiency of 80.183%, 99.21%, and 98.06% for calcium, silica, and magnesium ions, respectively, were obtained at a current de

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Tue Jan 01 2002
Journal Name
Annals Of Saudi Medicine
Treatment of viral warts by intralesional injection of zinc sulphate
...Show More Authors

KA Sharquie, AA Al-Nuaimy, Annals of Saudi Medicine, 2002 - Cited by 48

View Publication
Scopus (29)
Scopus
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Complications of Ponseti Technique in Treatment of Idiopathic Club Foot
...Show More Authors

Background: Clubfoot, or talipes equinovarus, is a congenital deformity that consist of; supination and adduction of the forefoot and midfoot; equinus of hindfoot and varus. It was found that more than 100,000 babies are born each year with congenital clubfoot

Objectives: The purpose of this study was to investigate the complications of  ponseti method for treatment of children with idiopathic club foot.

Subjects and Methods: 50 children with 74 clubfeet were managed by Ponseti method from May 2019 to July 2020 in Al-Wasity teaching hospital with primary correction of the deformity followed sometimes by elongation of Achilles tendon then the pati

... Show More
View Publication Preview PDF
Crossref