Background: Menstrual problems with all manifestations ranging from life-threatening bleeding to amen- orrhea are considered patterns of abnormal uterine bleeding (AUB), which is until now a popular reason for referral to the gynaecologic clinic and requires a special diagnostic tool. Objective: To assess the accuracy of hysteroscopy in diagnosing endometrial pathologies and to compare it with sonographic and histopathologic reports. Patients and Methods: A prospective study conducted in the Baghdad Teaching Hospital on 60 Iraqi females having varying complaints from abnormal uterine bleeding in pre- and post-menopausal women, infertility, and chronic pelvic pain with normal or abnormal ultrasound findings. Office hysteroscopy was done and an endometrial biopsy was obtained for histopathology for a period of 10 months between September 2020 and June 2021. Results: The current study showed that hysteroscopy was more accurate in diagnosing sensitivity of endo- metrial poly (100%), fibroids (83%), hyperplasia (84.2%), and cancer (50%) whereas ultrasounds were more accurate in diagnosing sensitivity to endometrial myoma (90%). Hysteroscopy and ultrasound showed low sensitivity in detecting endometrial cancer (50% and 34%, respectively). Conclusion: Although a transvaginal ultrasound was considered an integral part in the diagnosis of endo- metrial pathologies, it can be used for initial investigation, however, when suspecting endometrial pathol- ogy, hysteroscopy can be more advanced for evaluation, immediate treatment of endometrial masses, and obtaining targeted biopsies. Hysteroscopy showed high sensitivity in detecting endometrial polyps.
The research studied and analyzed the hybrid parallel-series systems of asymmetrical components by applying different experiments of simulations used to estimate the reliability function of those systems through the use of the maximum likelihood method as well as the Bayes standard method via both symmetrical and asymmetrical loss functions following Rayleigh distribution and Informative Prior distribution. The simulation experiments included different sizes of samples and default parameters which were then compared with one another depending on Square Error averages. Following that was the application of Bayes standard method by the Entropy Loss function that proved successful throughout the experimental side in finding the reliability fun
... Show MoreA new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO
... Show MoreThis study reports on natural convection heat transfer in a square enclosure of length (L=20 cm) with a saturated porous medium (solid glass beads) having same fluid (air) at lower horizontal layer and free air fill in the rest of the cavity's space. The experimental work has been performed under the effects of heating from bottom by constant heat flux q=150,300,450,600 W/m2 for four porous layers thickness Hp (2.5,5,7.5,1) cm and three heaters length δ(20,14,7) cm. The top enclosure wall was good insulated and the two side walls were symmetrically cooled at constant temperature. Four layers of porous media with small porosity, Rayleigh number range (60.354 - 241.41) and (Da) 3.025x10-8 has been investigated. The obtained data of temperatu
... Show MoreThe largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase
... Show MoreThe negotiation phase is gaining great importance in investment loans due to the magnitude of the amounts awarded and the need to obtain adequate lending guarantees and the development of better conditions, and this requires that negotiating policy with fixed principles that balance between meeting the demands of customers and maintain market share and achieve profits and avoid defaults and losses the bank, and so I have touched Find the concept of investment loans and procedures for granting and the concept of the negotiation process for the granting of loans. The practical side to ensure the preparation of examination form consists of questions commensurate with the methodology developed by the researchers, were directed to the officia
... Show MoreThe Khabour reservoir, Ordovician, Lower Paleozoic, Akkas gas field which is considered one of the main sandstone reservoirs in the west of Iraq. Researchers face difficulties in recognizing sandstone reservoirs since they are virtually always tight and heterogeneous. This paper is associated with the geological modeling of a gas-bearing reservoir that containing condensate appears while production when bottom hole pressure declines below the dew point. By defining the lithology and evaluating the petrophysical parameters of this complicated reservoir, a geological model for the reservoir is being built by using CMG BUILDER software (GEM tool) to create a static model. The petrophysical properties of a reservoir were computed using
... Show MoreIsolation and identification of bacterial isolates were carried out according to the morphology and biochemical characteristics on one hundred and twenty stool specimens collected from children under five years old via using biochemical tests and Api 20E compact system for further confirmation. Bacterial isolates were distributed as (34.48, 20.68, 5.17,0.86) % for Escherichia coli, Salmonella typhi ,Enterobacter aerogenos, Citrobacter freundii and Hafnia alvei respectively and 9.48 % for each Proteus mirabilis, Pseudomonas aeruginosa and Klebsiella Pneumonia. As well as, 2.58% for both Shigella sonnei and Serratia marcescens. Antibiotic susceptibility test for 116 bacterial isolates was performed towards 20 antibiotics types using disk d
... Show More