Background: Menstrual problems with all manifestations ranging from life-threatening bleeding to amen- orrhea are considered patterns of abnormal uterine bleeding (AUB), which is until now a popular reason for referral to the gynaecologic clinic and requires a special diagnostic tool. Objective: To assess the accuracy of hysteroscopy in diagnosing endometrial pathologies and to compare it with sonographic and histopathologic reports. Patients and Methods: A prospective study conducted in the Baghdad Teaching Hospital on 60 Iraqi females having varying complaints from abnormal uterine bleeding in pre- and post-menopausal women, infertility, and chronic pelvic pain with normal or abnormal ultrasound findings. Office hysteroscopy was done and an endometrial biopsy was obtained for histopathology for a period of 10 months between September 2020 and June 2021. Results: The current study showed that hysteroscopy was more accurate in diagnosing sensitivity of endo- metrial poly (100%), fibroids (83%), hyperplasia (84.2%), and cancer (50%) whereas ultrasounds were more accurate in diagnosing sensitivity to endometrial myoma (90%). Hysteroscopy and ultrasound showed low sensitivity in detecting endometrial cancer (50% and 34%, respectively). Conclusion: Although a transvaginal ultrasound was considered an integral part in the diagnosis of endo- metrial pathologies, it can be used for initial investigation, however, when suspecting endometrial pathol- ogy, hysteroscopy can be more advanced for evaluation, immediate treatment of endometrial masses, and obtaining targeted biopsies. Hysteroscopy showed high sensitivity in detecting endometrial polyps.
This study was design to investigate the dimensional stability of heat-activated acrylic resin with different methods of flask cooling (15 minutes rapid cooling, one hour bench cooling, four hours delayed deflasking, and 24 hours delayed deflasking) at different time intervals (immediately, two days, seven days, 30 days) after deflasking. Heat-activated acrylic resin was used to prepare acrylic samples. Then, measurement of the distances where achieved between the centers of selected marks in the acrylic samples. They were measured at different time intervals for different methods of flask cooling. The results showed that the group samples of the four hours and 24 hours of delayed deflasking was insignificantly different from the control an
... Show MoreTen isolates of Klebsiella pneumoniae, seven isolates of Pseudomonas aeruginosa and nine isolates of Staphylococcus aureus, were obtained from 100 urine samples collected from Baghdad hospitals. All isolates were identified biochemically and confirmed by using VITEK 2 and were then tested for their susceptibility towards 6 antibiotics and for phenolic extracts of Thymus vulgaris and Cinnamomum cassia. All bacteria were greatly affected by T. vulgaris, especially K. pneumoniae. Viable count was performed, it was noted that the number of bacterial cells reduced from 1×108 CFU to 1.2× 103, 2×105 and 1.8×106CFU of K. pneumoniae, P. aeruginosa and S. aureus respectively. While C. cassiahad a slight effect on them. K. pneumoniae isola
... Show MorePseudomonas aerogenosa lipopolysaccharidewas extracted by hot phenol method and purified by gel filtration method using the Sephadex G-200 gel and detected by the limulus amebocyt lysate (EU/ml 0.03)(Wako Chemicals USA, Inc.). The inhibitory effect of partially purified LPS on Candida glabrata yeast was studied in a microdilution method. This study found that LPS has an inhibitory effect on Candida glabrata with the lower concentrations. The inhibitory effect of LPS which treated with heating was studied under boiling and wet heat effect. The toxicity of LPS on Candida glabrata was not affected when treated with heating LPS and the results were similar to those found in untreated LPS
In this work, an efficient energy management (EEM) approach is proposed to merge IoT technology to enhance electric smart meters by working together to satisfy the best result of the electricity customer's consumption. This proposed system is called an integrated Internet of things for electrical smart meter (2IOT-ESM) architecture. The electric smart meter (ESM) is the first and most important technique used to measure the active power, current, and energy consumption for the house’s loads. At the same time, the effectiveness of this work includes equipping ESM with an additional storage capacity that ensures that the measurements are not lost in the event of a failure or sudden outage in WiFi network. Then then these
... Show MoreFiber Bragg Grating has many advantages where it can be used as a temperature sensor, pressure sensor or even as a refractive index sensor. Designing each of this fiber Bragg grating sensors should include some requirements. Fiber Bragg grating refractive index sensor is a very important application. In order to increase the sensing ability of fiber Bragg gratings, many methods were followed. In our proposed work, the fiber Bragg grating was written in a D-shaped optical fiber by using a phase mask method with KrFexcimer. The resultant fiber Bragg grating has a high reflectivity 99.99% with a Bragg wavelength of 1551.2 nm as a best result obtained from a phase mask with a grating period of 1057 nm. In this work it was found that the rota
... Show MoreAqueous extract of poppy plant) Papaver nudicaule) with five concentrations (50, 100, 150, 200 and 250) mg/l were used to anesthetize fingerlings of the common carp Cyprinus carpio (Mean total length 8.91 ± 0.31 cm and mean total weight 7.72 ± 1.19 gm) instead of the traditional use of MS-222. Results showed that extracted solution of poppy have partial and overall anesthesia effect on these fishes with inverse relationship between the concentrations used and the time needed to reach partial and overall anesthesia, and also direct relationship between concentrations used and time needed for fish recovery. Best results were obtained by using a concentration of 250 mg/l, where time for partial anesthesia was 8 ± 1.52 m
... Show MoreA Geographic Information System (GIS) is a computerized database management system for accumulating, storage, retrieval, analysis, and display spatial data. In general, GIS contains two broad categories of information, geo-referenced spatial data and attribute data. Geo-referenced spatial data define objects that have an orientation and relationship in two or three-dimensional space, while attribute data is qualitative data that can be counted for recording and analysis. The main aim of this research is to reveal the role of GIS technology in the enhancement of bridge maintenance management system components such as the output results, and make it more interpretable through dynamic colour coding and more sophisticated vi
... Show More