The research dealt with its forefront a definition of the aspects of the study and its variables, the explosive capacity and its relationship to the scoring of football for the halls and highlights the importance of these variables, and the problem of the research consisted that some players fail to score Amie because of the weak power of shots or the slow scoring, so the researchers saw studying this problem and knowing the extent of the influence of the explosive strength During the performance of the skill of scoring with five football, the study aimed to identify the relationship between the explosive strength and the skill of scoring with five football. Researchers assume that there is a statistically significant relationship between the force The explosive and scoring with five football, the sample was chosen in the random way, and it was made up of the fourth stage students, the College of Physical Education and Sports Science / Al -Farahidi University for the academic year 2021 - 2022 AD, which numbered 29 students from (247) after the researcher was excluded (4) students for their lack of cooperation as they reached The ratio of the sample (12%) of the total society of origin, and the statistical processes of the mathematical medium, the standard deviation and the correlation laboratory A relationship between the explosive force and the skill of scoring, and concluded from these results the emergence of various results of the influence of the explosive force on the players in performing the skill of scoring football for the halls. The emergence of a moral connection relationship between the explosive force of the two men and the scourge of football for the halls, and the researchers recommend the need to emphasize the skill performance that increases From the accuracy of the players ’performance and sends the correct idea they have. Coaches must prepare the players before entering the competition for the purpose of raising the physical and moral situation of the players.
The study includes histological structure of digestive tract of Liza abu , Anatomical results found that the digestive tract occupied the largest part of abdominal cavity , the mean gut length was (45.5) cm and relative gut length was (2.9) . esophagus was a muscular tube length (1.5) cm , esophagus wall containing longitudinal straight unbranched folds numbering (9) . Histological study results found that the esophagus composed of four tunica : mucosa , submucosa , muscularis and serosa . The results found that the mucosa consists of three layers : epithelium , lamina propria and muscularis mucosa . The epithelial layer was stratified squamous epithelium thickness (139.1) µ containing
... Show MoreThe micronucleated erythrocytes in fish was used to detect water pollution by genotoxic agents. Fish belonging to different species were collected from three regions from Baghdad during three months (December/2000,January and February/2001 ).The micronucleated erythrocytes was observed in all the specimens. It was concluded that the genotoxic activity' in one region was less than in die other two regions.?
Ten samples were collected from Injana and Mukdadiya Formations, representing 5 samples of fine grain sandstone (F) and 5 samples of very fine grain sandstone (VF). The heavy metals study showed that the opaque mineral recorded the highest percentage in comparison with other heavy metals. While, transparent minerals, including unstable minerals (Amphibole including Hornblend and Glaucophane) and (pyroxene including Orthopyroxene and Clinopyroxene), Metastable minerals including (Epidote, staurolite, Garnet, Kyanite) indicated metamorphic source, Ultrastable minerals (Zircon, Rutile, Tourmaline), Mica group (chlorite, biotite and muscovite). These accumulations indicate that the heavy minerals are derived from mafic igneous and metamorphi
... Show MoreIn this study, dependence of gamma-ray absorption coefficient on the size of Pb particle size ranging from 200µm up to 2.5mm, using different weights of each particle size. The results show that gamma-ray attenuation coefficient is inversely proportional with the size of Pb particle size due to the reduction of the spaces between the lead particles.
Cobalt substituted nickel copper ferrite samples with general formula Ni0.95-xCoxCu0.05Fe2O4, where (x= 0.00, 0.01, 0.02, 0.03, 0.04 and 0.05) were prepared by solid-state reactions method at 1373 K for 4h. The samples prepared were examined by X-ray diffraction (XRD(, atomic force microscope (AFM), Fourier transform infra-red spectroscopy (FTIR) and Vickers hardness. X-ray diffraction patterns confirm the formation of a single phase of cubic spinel structure in all the prepared samples . XRD analysis showed that the increase in the cobalt concentration causes an increase in the lattice constant, bulk density (ρm) and the x-ray density (ρx), whereas porosity (p) and crystallite size (D) decrease. The Topography of the surface observed
... Show MoreBackground: Deep vein thrombosis is a multi causal disease and its one of most common venous disorder, but only one quarter of the patients who have signs and symptoms of a clot in the vein actually have thrombosis and need treatment .The disease can be difficult to diagnose. Venous ultrasound in combination with clinical finding is accurate for venous thromboembolism, its costly because a large number of patients with suspicious signs and symptoms. Venography still the gold standard for venous thromboembolism but it is invasive. The D-dimer increasingly is being seen as valuable tool rolling out venous thromboembolism and sparing low risk patients for further workup.Objectives: this study has designed the role of D-dimer to confirm diag
... Show MoreIn this paper, some estimators for the reliability function R(t) of Basic Gompertz (BG) distribution have been obtained, such as Maximum likelihood estimator, and Bayesian estimators under General Entropy loss function by assuming non-informative prior by using Jefferys prior and informative prior represented by Gamma and inverted Levy priors. Monte-Carlo simulation is conducted to compare the performance of all estimates of the R(t), based on integrated mean squared.
The present investigation considers the effect of curing temperatures (30, 40, and 50˚C) and curing compound method on compressive strength development of high performance concrete, and compares the results with concrete cured at standard conditions and curing temperature (21˚C). The experimental results showed that at early ages, the rate of strength development at high curing temperature is greater than at lower curing temperature, the maximum increasing percentage in compressive strength is 10.83% at 50C˚ compared with 21C˚ in 7days curing age. However, at later ages, the strength achieved at higher curing temperature has been less, and the maximum percentage of reduction has been 5.70% at curing temperature 50C˚ compared with 21
... Show MoreSheets of Epoxy (EP) resin with addition of TiO2 of grain size (1.5μm, and 50nm) and weight percentage (1%, 3%, and 5%) were prepared. Discs of 20mm diameter and 3mm thickness were cut for dielectric measurements. Dielectric properties (dielectric constant, dispassion factor and electrical conductivity) over the frequency range 102 -106 Hz were measured.
Comparison was made between the effect of micro and nano particles of TiO2 on the dielectric properties of EP composites with different weight percentage. Epoxy composites with micro sized particles of TiO2 were observed to have the better values of dielectric properties.
A hand lay-up method was used to prepare Epoxy/ metal composites. Epoxy resin (EP) was used as a matrix with metal particles (Al, Cu, and Fe) as fillers.
The preparation method includes preparing square panels of composites with different weight percentage of fillers (10, 20, 30, 40, and 50%). Standard specimens (88mm in diameter) for thermal conductivity tests were prepared to measure thermal conductivity kexp.The result of experimental thermal conductivity kexp, for EP/metal composites show that, kexp increase with increasing weight percentage, For EP/ Al and EP/Cu composites, and it have have maximum values of 0.33 and 0.35 W/m.K, respectively. While kexp for EP/ Fe composite show slight increase with maximum value of 0.186 W/m.K.