The increase in the use of thyme in Iraq and neighboring countries, which may
be result in serious side effects necessitate the demand for testing different
concentrations of thyme extract (500,750,1000) mg/kg of body weight on rats to be
given either by injection or feeding grinded dried thyme leaves added to pellets
(50,100,150) g /kg of pellet in of different periods , (10,20,30) days for injection
and feeding 2 times weekly. Thyme extracts leaves effects on RBCs, WBCs and
Differential WBCs counts were measured. statistical analysis showed significance
increase difference (P≤0.05) in RBCs, WBCs and Lymphocyte, Nutrophile and
Monocyte counts and decrease in Eosinphil counts in rats treated with 1000 mg of
t
This work is an experimental study about the effects of gas pressure and magnetic field on plasma characteristics produced in an internal hollow electrodes discharge (HED) system. The results show that the breakdown voltage values increase with increasing the working pressure (especially with the presence of a magnetic field). The breakdown voltage depends on the p.d. product, where p is the gas pressure and d is the distance between the electrodes. While the values of current discharge decrease with the increase of the working pressure. The temperature of electron and the number density of electron are calculated from the Boltzmann method and the broadening of Stark, respectively. The results showed that the electron number d
... Show MoreThis study was designed to investigate the effect of thyroid hormone disturbance on lipids profiles and liver functions. Eighteen mature male rats Rattus norvegicus were divided into three groups. The first and the second groups were injected subcutaneously with thyroxine (T4) and carbimazol (both at 600 µg/kg BW) respectively on alternate days, to produce recurrent periods of hyper and hypothyroidism .The control group which is the third group was injected with physiological saline. The process continued 4 weeks, after that, injection, blood specimens were collected to estimate serum levels of T3 and T4, Total cholesterol (TC), Triglycerides (TG), High density lipoprotein cholesterol (HDL-C), Low density lipoprotein cholesterol (LDL-C) an
... Show MoreIn this work, plasma system that operates at vacuum was designed and built using a sheet of cobalt metal for the purpose of diagnosing plasma and measuring its parameters, as it is very important to know the processes that accompany plasma generation and are closely related to them, including the electron density in the plasma and its temperature. The spectroscopic diagnosis was done by optical emission spectroscopy (OES) which relies on the calculation of the optical radiation emitted by the plasma to describe plasma parameters in the chemical, molecular, and ionic radiator's near environment, and applied to cobalt metal at vacuum D.C high voltage power supply. The results showed the rise of spectral lines intensity with increa
... Show MoreTheoretical calculations are achieved to study the effect of different deuterium pressures on various characteristics parameters for PF400J plasma focus using an international computer code. Axial and radial velocities, voltage tube, plasma temperatures, and neutron yields at different operating deuterium pressures are computed. Neutron emission has been calculated in the device. The maximum total neutron yield calculated is of the order of and neutrons per shot for entire pressure used. The computed results agree reasonably well with the published neutron yield curves.
In the present study, gold nanoparticles (AuNPs) were prepared using a simple low cost method synthesized cold plasma at different exposure time . The nanoparticles were characterized using UV-Visible spectra, X-ray diffraction (XRD). The prepared AuNPs showed surface Plasmon resonance centered at 530, 540,and 533 nm. The XRD pattern showed that the strong intense peaks indicate crystalline nature and face centered cubic structure of gold nanoparticles for all samples were prepared .The average crystallite size of the AuNPs was 20-40 nm. Morphology of the AuNPs were carried out using FESEM. Observations show that the AuNPs synthesized we well dispersed with and particle sizes ranging from 9 to 31 nm with spherical shapes which are cle
... Show MoreAbstract: This study was aimed to investigate the effect of two doses of pregabalin (PGB) on hormonal level and sexual activity in female albino rats. Ninety female rats with age (9-10 weeks) and weight (200±20 g) were divided into three major groups of thirty rats. First group was considered as control G1, the second G2 and third G3 groups were exposed to PGB into two doses 150, and 300 mg/kg body weight per day respectively. Each major group was divided into three subgroups (subgroup A, B, and C of each has ten rats), the treatments last for one month for subgroup A, two months for subgroup B, and three months for subgroup C. Five rats from each subgroup were placed separately into two breeding cages with two isolated males and wait
... Show MoreComsol multiphysics software is established to make a simulation that is comparable with experimental device. by utilizing comsol, the positive column domain of direct-current glow discharge with argon is considered for both of different applied voltage and working gas pressure. The calculations are exhibited by using a precise collision cross sections and Townsend coefficients for the argon. The impacts of voltage and pressure on the Debye length, number of particles in Debye sphere and plasma frequency are calculated and graphically delineated. With this regard to the dependence of plasma parameters on the applied voltage and pressure, some of them are found to be compatible with the experimental
... Show MoreThe research aims to develop and build a plasma jet system operating under atmospheric pressure.for biological purposes. The advanced plasma system consists of a power supply and a plasma torch. The source of the development of the system is a previous laboratory system that was developed by changing the voltage and frequency of the power supply, as the power provider equips the system with a voltage in the form of a sine wave whose value is fixed at about (7.5kV) peak to peak and its frequency is about (28 kHz). The plasma torch consists of a teflon tube with of width of (10 m ) located at (10mm) from the end of the tube. The current waveform and voltage wave were measured using a current and voltage sensor and an oscilloscop
... Show MoreBackground: Among different air pollutants, cigarette smoke contains toxic chemicals, mutagenic and carcinogenic compounds, which can adversely affect male fertility. In this study, semen parameters and reproductive hormonal concentrations of subfertile smokers were compared with subfertile non-smokers.
Objectives: evaluation of the effect of cigarette smoking on male fertility by evaluating several semen parameters as well as some reproductive hormones in a group of smoker and non smokersubfertile Iraqi subjects.
Patients and Methods: At the male infertility clinic of Al-yarmuk teaching hospital, Almustanseria medical college, Baghdad, Iraq from the 1st of October 2010 to the end of June 2011, 88 men (49 non-smokers, and 39 smoker