Background: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts. Objectives: To evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with hand held ultrasound in detection and characterization of breast lesions in women with dense breast. Subjects and Methods: A prospective observational study conducted at Oncology Teaching Hospital during the period of ten months from 1st of February till 1st of December 2020. Included 62 women with dense breasts on diagnostic mammograms. All women underwent technician performed automated breast ultrasound and radiologist performed handheld ultrasound for both breasts. All suspicious lesions with selected probably benign lesions underwent biopsy, handheld ultrasound detected 48 masses (67.6%), 15 of them (21.1%) were cystic, automated breast ultrasound detected 54 masses (76.1%); 20 of them (28.2%) were cystic. The sensitivity of handheld ultrasound was=87.5%, Specificity=58.8%, the sensitivity of automated breast ultrasound was=93.8%, Specificity=70.6%. Conclusion: Automated breast ultrasound is an effective modality to detect occult breast lesion in women with dense breasts, automated breast ultrasound and handheld ultrasound have a reliable agreement in detection and characterization of breast lesions with higher accuracy of automated breast ultrasound in the evaluation of malignant lesions.
In this work, Kinetic Phosphorescence Analyzer (KPA) has been used to measure the concentrations of uranium (UC) and Amorphous crystals (AMO) in urine samples of breast cancer patients in Baghdad. Additionally, a relation between UC and AMO with respect to patient's age has been deduced and studied.
Forty one urine samples of patients and five for healthy were taken from females lived in different residential area of Baghdad. The measured maximum UC value for urine samples of patients was 2.35 ± 0.053, the minimum value was 0.86 ± 0.034 μg/L, and an overall average was 1.6 ± 0.027 μg/L while the average UC for healthy females was 1.03 ± 0.020 μg/L.
From these results, AMO concentrations were found for all breast cancer patie
Breast cancer is a disease in which cells in the breast grow out of control. CD200 is a cell surface glycoprotein expressed on many cells, it belongs to the immunoglobulin family (Ig) and have a great role in the regulation of inflammation in autoimmunity. CD200 is the ligand for CD200R1 receptor. To determine if serum level of CD200 and its receptor CD200R1 can be used as a diagnostic and prognostic marker in patients with breast cancer.This case control study was carried out at Oncology Teaching Hospital – Medical city in Baghdad. Six groups were enrolled, four groups were confirmed with breast cancer stage (I, II, III and IV), fifth group (benign) and sixth group was control (healthy individual). Serum is divided to me
... Show MoreBreast cancer (BC) is one of the most frequently observed malignancy in females worldwide. Today, tamoxifen (TAM) is considered as the highly effective therapy for treatment of breast tumors. Oxidative stress has implicated strongly in the pathophysiology of malignancies. This study aimed to investigate the changes in the levels of oxidants and antioxidants in patients with newly diagnosed and TAM-treated BC. Sixty newly diagnosed and 60 TAM-treated women with BC and 50 healthy volunteers were included in this study. Parameters including total oxidant capacity (TOC), total antioxidant capacity (TAC), and catalase (CAT) activity were determined before and after treatment with TAM. The serum levels of TOC and oxidative stress index (OSI) were
... Show More
CD-nanosponges were prepared by crosslinking B-CD with diphenylcarbonate (DPC) using ultrasound assisted technique. 5-FU was incorporated with NS by freeze drying, and the phase solubility study, complexation efficiency (CE) entrapment efficiency were performed. Also, the particle morphology was studied using SEM and AFM. The in-vitro release of 5-FU from the prepared nanosponges was carried out in 0.1N HCl.
5-FU nanosponges particle size was in the nano size. The optimum formula showed a particle size of (405.46±30) nm, with a polydispersity index (PDI) (0.328±0.002) and a negative zeta potential (-18.75±1.8). Also the drug entrapment efficiency varied with the CD: DPC molar ratio from 15.6 % to 30%. The SEM an
... Show MoreBreast cancer is the most prevalent malignancy among women worldwide, in Iraq it ranks the first among the population and the leading cause of cancer related female mortality. This study is designed to investigate the correlations between serum and tissue markers in order to clarify their role in progression or regression breast cancer. Tumor Markers are groups of substances, mainly proteins, produced from cancer cell or from other cells in the body in response to tumor. The study was carried out from April 2018 to April 2019 with total number of 60 breast cancer women. The blood samples were collected from breast cancer women in postoperative and pretherapeutic who attended teaching oncology hospital of the medical city in Baghdad and
... Show MoreThis study evaluated the knowledge and practice of breast self-examination (BSE), among a sample of educated Iraqi women. The study sample comprised 858 women aged 18–62 years affiliated to 6 major Iraqi universities, categorized according to occupation as teaching staff (11.5%), administrative staff (18.0%) and students (70.5%). Data were collected by a self-completed questionnaire. In all, 93.9% of the women had heard about BSE, the main source of information was television (39.9%), doctors (18.4%) and the awareness campaign of the Iraqi National Breast Cancer Research Programme (11.6%). Only 53.9% of the women practised BSE; the most common excuses by those that did not were lack of knowledge of the significance of BSE (42.0%) and lack
... Show MoreAnaemia is a crucial issue among cancer patients and need to be treated properly. High incidence of anaemia in patients with cancer have been associated with several physiological manifestations, leading to decreased quality of life (QOL).
The current study aimed to assess the severity of anaemia, evaluate the current treatment guideline of anaemia, and to determine the association between the level of anaemia and its treatment on quality of life of breast cancer patients in Malaysia. This prospective study conducted among breast cancer patients in multicancer centers in Malaysia including three follow ups after receiving their chemotherapy. Clinical data were collected from their medical records and at each follow up, they asked
... Show MoreImaging by Ultrasound (US) is an accurate and useful modality for the assessment of gestational age (GA), estimation fetal weight, and monitoring the fetal growth during pregnancy, is a routine part of prenatal care, and that can greatly impact obstetric management. Estimation of GA is important in obstetric care, making appropriate management decisions requires accurate appraisal of GA. Accurate GA estimation may assist obstetricians in appropriately counseling women who are at risk of a preterm delivery about likely neonatal outcomes, and it is essential in the evaluation of the fetal growth and detection of intrauterine growth restriction. There are many formulas are used to estimate fetal GA in the world, but it's not specify fo
... Show More