Utilizing the Turbo C programming language, the atmospheric earth model is created from sea level to 86 km. This model has been used to determine atmospheric Earth parameters in this study. Analytical derivations of these parameters are made using the balancing forces theory and the hydrostatic equation. The effects of altitude on density, pressure, temperature, gravitational acceleration, sound speed, scale height, and molecular weight are examined. The mass of the atmosphere is equal to about 50% between sea level and 5.5 km. g is equal to 9.65 m/s2 at 50 km altitude, which is 9% lower than 9.8 m/s2 at sea level. However, at 86 km altitude, g is close to 9.51 m/s2, which is close to 15% smaller than 9.8 m/s2. These results have been compared with an international standard atmosphere. The presumed atmosphere model differs significantly from the actual atmosphere because weather fluctuations are not taken into consideration in this model.
Background: Soft Laser has been advantageous in medical applications and is widely used in clinical practice. It is applied because it doesn’t cause the significant thermal effects or tissue hurt when irradiated. The blood response to low power laser radiation provides information about processes of laser radiation interaction with live creatures. Objective: The aim of the current work was to evaluate the laser-induced changes of in vitro erythrocyte sedimentation rate (ESR), mean corpuscular volume (MCV), and mean corpuscular hemoglobin concentration (MCHC) in patients with breast cancer by irradiating a human blood sample using a green laser and comparing its effects before and after irradiation with the same power density (100mW/c
... Show MoreGe-Au infrared photoconductive detection was prepared from germanium single crystal which were doped with different gold concentration using thermal evaporation. The spectral resonsivity (Rλ), spectral detectivity (D*) were determined as function of wavelength, also the resistance, conductivity in dark and with illumination to infrared radiation, the gain and relative photo response have been measured with different gold concentration. Remarkable improvements in the photoresponse gain were observed for the highest resistance specimen at the expense of spectral detectivity values.
Abstract: The research aims to assess the level of readiness of the Information and Communication Technology (ICT) infrastructure for business continuity at Earthlink Telecommunications and Internet Services Company in Iraq, in light of the requirements of the international standard ISO/IEC 27031:2025. The research adopts a case study approach as an appropriate methodological framework for understanding and analyzing the organizational and technical complexity inherent in telecommunications sector organizations. To achieve the research objectives, a set of integrated data collection tools was employed, including field interviews with technical and administrative staff, a review of organizational documents and approved policies, as well as d
... Show MoreThe objective of this study is to examine the properties of Bayes estimators of the shape parameter of the Power Function Distribution (PFD-I), by using two different prior distributions for the parameter θ and different loss functions that were compared with the maximum likelihood estimators. In many practical applications, we may have two different prior information about the prior distribution for the shape parameter of the Power Function Distribution, which influences the parameter estimation. So, we used two different kinds of conjugate priors of shape parameter θ of the <
... Show MoreAt the last years, the interesting of measurement spicilists was increased to study differential item functioning (DIF) wich is reflect the difference of propability true response for test item from subgroups which have equal level of ability . The aims of this research are, inform the DIFat Namers’scale(2009) for mental health to prepare students and detect items that have DIF. Sample research contants (540) students, we use Mantel- Haenzel chi-square to detect DIF. The results are point to there are (26) items have DIF according to gender which are delated form the scale after that.
Praise be to God, Lord of the worlds, and prayers and peace be upon our master Muhammad and his family and companions until the Day of Judgment.
The words of God Almighty are for the sake of the greatest and greatest speech, and the scholars, may God have mercy on them, raced.
To dive into knowing the word of God and what he intended, so they wrote in it the literature and collected works in it, and explained it to those after them.
And when the noble companions, were extremely eloquent and eloquent, because the Holy Qur’an was revealed in the language of the Quraysh, and all the Arabs knew their language, they understood the Holy Qur’an and applied it p
This paper compare the accurecy of HF propagation prediction programs for HF circuits links between Iraq and different points world wide during August 2018 when solar cycle 24 (start 2009 end 2020) is at minimun activity and also find out the best communication mode used. The prediction programs like Voice of America Coverage Analysis Program (VOACAP) and ITU Recommendation RS 533 (REC533 ) had been used to generat HF circuit link parameters like Maximum Usable Frequency ( MUF) and Frequency of Transsmision (FOT) .Depending on the predicted parameters (data) , real radio contacts had been done using a radio transceiver from Icom model IC 7100 with 100W RF
... Show MoreAIM: To determine the value of the combination of thin-section 3 mm coronal and standard axial DWI and their impact in facilitating the diagnosis of acute brainstem infarction. METHODS: A cross-sectional study conducted from the 1st of April 2017 to the end of February 2018 on 100 consecutive patients (66% were male, and 34% were female) with isolated acute ischemic infarction in the brainstem. The abnormal MRI findings concerning the ischemic lesions were interpreted on standard axial 5 mm and thin-section coronal 3mm DWI. RESULTS: The mean age of the studied group was 69.2 ± 4.3 for male and 72.3 ± 2.5 years. The standard axial DWI can diagnose 20%, 6.7% and 6.7% of the infarctions in midbrain, pons an
... Show More