Background: Recent research indicates that persistent inflammatory responses may contribute to the rise of diabetic nephropathy (DN) and diabetic cardiovascular disease (DCVD) in type 2 diabetes mellitus patients (DM2). Numerous molecules associated with inflammation and angiogenesis have been implicated in the development and progression of DN and DCVD, respectively. Methods: The subjects were separated into five groups: healthy controls (n= 25), type 2 diabetes mellitus patients (n= 30), type 2 diabetes mellitus patients with nephropathy DN (n= 30), and type 2 diabetes mellitus patients with cardiovascular disease DCVD (n= 30). The blood levels of irisin, IL-8, HbA1C, urea, and creatinine were determined. Results: In current study there w
... Show MoreA fracture is a damage to bone tissue that causes damage to the tissue surrounding the bone and may penetrate the skin. Subjects and methods: the present study included (80) fractured Iraqi patients (and 40) patients with DM2 and (40) without DM2 and compared them with (40) healthy control. Patients and control are matched in age. This study showed a significant increase in retinol-binding protein 4 (RBP4) and a considerable decrease in Vit .A GPT and GOT in fracture patients with and without DM2. In addition, there was a significant negative correlation between RBP4 with (GPT and GOT) in fracture patients with DM2 and a significant positive correlation between RBP4 with (GPT and GOT) in fracture patients without DM2.
... Show MoreTo demonstrate the effect of changing cavity length for FM mode locked on pulse parameters and make comparison for both dispersion regime , a plot for each pulse parameter as Lr function are presented for normal and anomalous dispersion regimes . The analysis is based on the theoretical study and the results of numerical simulation using MATLAB. The effect of both normal and anomalous dispersion regimes on output pulses is investigate Fiber length effects on pulse parameters are investigated by driving the modulator into different values. A numerical solution for model equations using fourth-fifth order, Runge-Kutta method is performed through MATLAB 7.0 program. Fiber length effect on pulse parameters is investigated by driving th
... Show MoreFeed Forward Back Propagation artificial neural network (ANN) model utilizing the MATLAB Neural Network Toolbox is designed for the prediction of surface roughness of Duplex Stainless Steel during orthogonal turning with uncoated carbide insert tool. Turning experiments were performed at various process conditions (feed rate, cutting speed, and cutting depth). Utilizing the Taguchi experimental design method, an optimum ANN architecture with the Levenberg-Marquardt training algorithm was obtained. Parametric research was performed with the optimized ANN architecture to report the impact of every turning parameter on the roughness of the surface. The results suggested that machining at a cutting speed of 355 rpm with a feed rate of 0.07 m
... Show MoreThis paper provides an attempt for modeling rate of penetration (ROP) for an Iraqi oil field with aid of mud logging data. Data of Umm Radhuma formation was selected for this modeling. These data include weight on bit, rotary speed, flow rate and mud density. A statistical approach was applied on these data for improving rate of penetration modeling. As result, an empirical linear ROP model has been developed with good fitness when compared with actual data. Also, a nonlinear regression analysis of different forms was attempted, and the results showed that the power model has good predicting capability with respect to other forms.
ABSTRACT Background: This study aimed to study the effect of some acidic drinks (Vinegars and fresh Orange juice) and energy drinks (Red bull) on surface roughness of three types of bulkfill composite materials: Filtek posterior bulkfill (3M), Sonicfill (Kerr) and Filtek p60 (3M). Materials and Methods: Total number of 120 samples are prepared by using a mold of (12mm diameter and 3mm height), which were divided into three groups forty samples for each group: Group A: Filtek bulkfill posterior composite (3M), Group B: Sonicfill composite (Kerr), Group C: Filtek P60 (3 M) which then divided into four sub- groups (n=10) (1) samples were kept in distilled water as a control group (2) samples were immersed in Redbull (3) samples were immersed
... Show MoreBackground: Although various imaging modalities are available for evaluating suspicious breast lesions, ultrasound-based Shear-Wave Elastography (SWE) is an advanced, non-invasive technique complementary to grayscale sonography. This technique evaluates the elasticity of a specific tissue by applying sonic pressure to that tissue.
Objective: The aim is to assess the role of SWE in evaluating solid breast masses in correlation to histopathological study results.
Subjects and Methods: This prospective study was done in a tertiary care teaching hospital from September 2019 to August 2020. A study population of 50 women aged 18 years or above with an
... Show More