Preferred Language
Articles
/
nRcsno0BVTCNdQwCxBbn
The effect of composite bonding spot size and location on the performance of poly-ether-ether-ketone (PEEK) retainer wires
...Show More Authors

Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of the crown, closer to the lateral incisor. The linear displacement of the teeth, strains of the periodontal ligament, and stresses in PEEK wire and composite were evaluated. The data was numerically produced with color coded display by the software. Selected values were tabulated and compared among models. Results: The amount of linear displacement and strain was very low. Stresses in the wire and composite were affected by the size and position of the composite bonding spot. The safe limits were identified at 235 MPa for PEEK and 100 MPa for composite. The basic model had a von Mises stress in the PEEK wire of 122.09 MPa, and a maximum principal stress in the composite of 99.779 MPa. Both stresses were within the safe limits, which means a lower risk of failure in PEEK and composite. All other models had stresses that exceeded the safe limit of the composite. The 3 mm composite model was the only one that developed stresses in the wire more than the safe limits of PEEK. Conclusions: Within the limitations of this study, bonding PEEK wires with 4 mm bonding spots to the clinical crown center provided the best mechanical performance of the wires and spots; otherwise, the mechanical properties of the wire and composite would be affected and, therefore, might affect the retention process. Keywords: Retention, PEEK, Finite element analysis

Scopus Crossref
Publication Date
Mon Dec 30 2024
Journal Name
Journal Of The College Of Education For Women
The Effect of Dictogloss Technique on University EFL Students' Collocation Knowledge
...Show More Authors

تتمثل مشكلة الدراسة في الصعوبات التي يواجهها طلاب اللغة الإنجليزية كلغة أجنبية في تعلم وإتقان المتلازمات اللفظية. تهدف هذا الدراسة تهدف إلى تحديد أثر استخدام تقنية المسرد الاملائي على معرفة المتلازمات اللفظية لدى الطلاب. ولتحقيق أهداف هذا البحث والتحقق من فرضياته تم اختيار عينة عشوائية مكونة من (60) طالبة من كلية اللغة الإنجليزية للسنة الثانية باستخدام كتاب الفهم القرائي المقرر للمستوى الثاني في قسم الل

... Show More
View Publication
Crossref
Publication Date
Sun Jun 08 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of inhaled corticosteroid on condition oral among asthmatic children
...Show More Authors

Background: Inhalation therapy has been employed as the mainstay of the treatment in chronic respiratory diseases such as asthma, Patients who taking asthma medication may be at risk of many health problems including oral health .The purpose of this study was to assess the local effect of ICS on oral tissue by measuring Candida albicans count colonies in saliva among12 years old asthmatic children who were collected from AL- Zahra Center Advisory for Allergy and Asthma, and compares them with non asthmatic children of the same age and gender. Material and Methods: The total sample involved sixty children of 12 years old, thirty asthmatic children who received medium dose of ICS/day (200-400 microgram/day) for 2 years and 30 non-asthmatic ch

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
The Effect of Gas Flow on Plasma Parameters Induced by Microwave
...Show More Authors

In this paper, construction microwaves induced plasma jet(MIPJ) system. This system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate by using flow meter, to diagnose microwave plasma optical emission spectroscopy(OES) was used to measure the important plasma parameters such as electron temperature (Te), residence time (Rt), plasma frequency (?pe), collisional skin depth (?), plasma conductivity (?dc), Debye length(?D). Also, the density of the plasma electron is calculated with the use of Stark broadened profiles

View Publication Preview PDF
Scopus (18)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Gamma Ray Effect on the Properties of Coumarin C47 Laser Dye
...Show More Authors

The research is concerned about studying the absorption spectrum of the solution coumarin dye C47. The chloroform solvent was used with C47 dye in three different concentrations 10-4, 10-5 and 10-6 M. The laser dye solution was prepared by dissolving the required amount of dye in chloroform alcohol, while studying absorption spectrum before and after irradiation with gamma ray by cobalt-60 source 60Co at exposure time, which are 0, 4, 6 and 18 hours with different absorbed doses 0, 136, 204 and 612 Gy. The results show that red shift in the absorption spectrum was increased by increasing the concentration of laser dye solutions , while the increase of gamma dose led to increase the red shift after irradiation, as the exposure period and irr

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Wed Oct 03 2018
Journal Name
Opcion
Evaluating the financial performance according to the traditional and modern financial indicators
...Show More Authors

The research aims to develop the general performance and improve the level of activity of private insurance companies in line with the current progress of the country. Besides, Evaluating financial performance to diagnose weaknesses and strengths in sample research companies and then developing appropriate solutions. The deviation in the financial performance of the research sample was revealed by measuring the various accounts of the company. The research sample included five companies in the private insurance sector listed in the Iraqi Stock Exchange Market, which represent the private insurance sector. The research concluded that the added economic value is a broad concept that goes beyond the traditional performance evaluation process a

... Show More
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Evaluation The Performance Geodetic of the Receivers Using Static Positioning Technique
...Show More Authors

Global Navigation Satellite System (GNSS) is considered to be one of the most crucial tools for different applications, i.e. transportation, geographic information systems, mobile satellite communications, and others. Without a doubt, the GNSS has been widely employed for different scientific applications, such as land surveying, mapping, and precise monitoring for huge structures, etc. Thus, an intense competitive has appeared between companies which produce geodetic GNSS hardware devices to meet all the requirements of GNSS communities. This study aims to assess the performance of different GNSS receivers to provide reliable positions. In this study, three different receivers, which are produced by different manufacturers, were fi

... Show More
View Publication
Crossref
Publication Date
Mon Sep 30 2013
Journal Name
International Journal Of Network Security & Its Applications
Evaluating the Performance of the Secure Block Permutation Image Steganography Algorithm
...Show More Authors

Recently, a new secure steganography algorithm has been proposed, namely, the secure Block Permutation Image Steganography (BPIS) algorithm. The new algorithm consists of five main steps, these are: convert the secret message to a binary sequence, divide the binary sequence into blocks, permute each block using a key-based randomly generated permutation, concatenate the permuted blocks forming a permuted binary sequence, and then utilize a plane-based Least-Significant-Bit (LSB) approach to embed the permuted binary sequence into BMP image file format. The performance of algorithm was given a preliminary evaluation through estimating the PSNR (Peak Signal-to-Noise Ratio) of the stego image for limited number of experiments comprised hiding

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 26 2022
Journal Name
Journal Of Advanced Research In Hr And Organizational Management
Entrepreneurial Performance of the Organization According to the Approved Training Strategy
...Show More Authors

The research aims to determine the role of the training strategy with its dimensions of (strategic analysis, formulation of training strategy, implementation of training strategy, evaluation) in the pioneering performance of the organization with its dimensions of (pre-planning , renewal and modernization, efficiency, effectiveness). Important and modern in pioneering performance and training strategy, and in recognition of the importance of the subject and the expected results of the surveyed banks, an analysis was made of the data obtained through field visits in addition to the questionnaire and interviews ,and the most prominent results that were reached were taking the research sample into consideration all the requirements of the trai

... Show More
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Evaluation The Performance Geodetic of the Receivers Using Static Positioning Technique
...Show More Authors

Global Navigation Satellite System (GNSS) is considered to be one of the most crucial tools for different applications, i.e. transportation, geographic information systems, mobile satellite communications, and others. Without a doubt, the GNSS has been widely employed for different scientific applications, such as land surveying, mapping, and precise monitoring for huge structures, etc. Thus, an intense competitive has appeared between companies which produce geodetic GNSS hardware devices to meet all the requirements of GNSS communities. This study aims to assess the performance of different GNSS receivers to provide reliable positions. In this study, three different receivers, which are produced by different manufactur

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Journal Of Engineering
The The Optimum Reservoir Performance of Nahr Umr/Ratawi Oil Field
...Show More Authors

Reservoir study has been developed in order to get a full interesting of the Nahr Umr formation in Ratawi oil field. Oil in place has been calculated for Nahr Umr which was 2981.37 MM BBL. Several runs have been performed to get matching between measured and calculated of oil production data and well test pressure. In order to get the optimum performance of Nahr Umr many strategies have been proposed in this study where vertical and horizontal wells were involved in addition to different production rates. The reservoir was first assumed to be developed with vertical wells only using production rate of (80000–125000) STB/day. The reservoir is also proposed to produce using horizontal wells besides vertical wells with pr

... Show More
View Publication Preview PDF
Crossref