Preferred Language
Articles
/
nRcsno0BVTCNdQwCxBbn
The effect of composite bonding spot size and location on the performance of poly-ether-ether-ketone (PEEK) retainer wires
...Show More Authors

Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of the crown, closer to the lateral incisor. The linear displacement of the teeth, strains of the periodontal ligament, and stresses in PEEK wire and composite were evaluated. The data was numerically produced with color coded display by the software. Selected values were tabulated and compared among models. Results: The amount of linear displacement and strain was very low. Stresses in the wire and composite were affected by the size and position of the composite bonding spot. The safe limits were identified at 235 MPa for PEEK and 100 MPa for composite. The basic model had a von Mises stress in the PEEK wire of 122.09 MPa, and a maximum principal stress in the composite of 99.779 MPa. Both stresses were within the safe limits, which means a lower risk of failure in PEEK and composite. All other models had stresses that exceeded the safe limit of the composite. The 3 mm composite model was the only one that developed stresses in the wire more than the safe limits of PEEK. Conclusions: Within the limitations of this study, bonding PEEK wires with 4 mm bonding spots to the clinical crown center provided the best mechanical performance of the wires and spots; otherwise, the mechanical properties of the wire and composite would be affected and, therefore, might affect the retention process. Keywords: Retention, PEEK, Finite element analysis

Scopus Crossref
Publication Date
Fri Mar 18 2022
Journal Name
International Journal Of Health Sciences
Histological and Immunohistochemical Study of the Protective Effect of Virgin Coconut Oil on Cyclophosphamide-induced Immunotoxicity of the Spleen and Peyer’s Patches
...Show More Authors

Publication Date
Thu Jun 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Controller work specificity and their impact on performance (Applied Study in the financial oversight bodies)
...Show More Authors

The research aims to a statement of specificity of the Controller of (academic achievement, specialty, job title, length of service, Gender) and its impact on performance, Through a proposed appraisal form includes three main axes and each axis including several specialized elements in the supervisory work in form (check list). as is the importance of research to enable officials of oversight bodies financial identify and diagnose performance Controller through what has this observer of the process of scientific properties when performing supervisory work. Be summarized problem of the research that the lack of regulatory institution with the Controller interesting in terms of the necessary characteristics and requirements and inv

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Journal Of Engineering
Fault Location of Doukan-Erbil 132kv Double Transmission Lines Using Artificial Neural Network ANN
...Show More Authors

Transmission lines are generally subjected to faults, so it is advantageous to determine these faults as quickly as possible. This study uses an Artificial Neural Network technique to locate a fault as soon as it happens on the Doukan-Erbil of 132kv double Transmission lines network. CYME 7.1-Programming/Simulink utilized simulation to model the suggested network. A multilayer perceptron feed-forward artificial neural network with a back propagation learning algorithm is used for the intelligence locator's training, testing, assessment, and validation. Voltages and currents were applied as inputs during the neural network's training. The pre-fault and post-fault values determined the scaled values. The neural network's p

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Sat Feb 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
The impact of customer contact on operation performance Case study in the specialist Dental Centre in Al-alwia
...Show More Authors

the researchers Sought to determine the impact of the customer contact (Within a client contact there are two times, first is the total time required to create a service and within it there is contact time while the second time is the time of client contact ؛ where means a time that records the physical presence of the customer during the process of service) on operations performance by concentrate attention on the cost (labor productivity) and quality (patient ratio to the doctor) and speed (cycle time) and flexibility (the flexibility range) , as well as ruling out variable of innovation because of impossibility to measure this variable in the Specialty Center for Dental in al-alwia due to the center is lacking of mechanisms t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 13 2018
Journal Name
Journal Of Engineering
Investigating the Influence of the Cerium loading in prepared Y zeolite from Iraqi kaolin on its Catalytic Performance
...Show More Authors

In this study, the effects of different loading doses of cerium in the prepared NaY zeolite from Iraqi kaolin were investigated. Al-Duara  refinery atmospheric residue fluid catalytic cracking was selected as palpation reaction for testing the catalytic activity of cerium loading NaY zeolite.  The insertion of cerium in NaY zeolites has been synthesized by simple ion exchange methods. Three samples of modified zeolite Y have been obtained by replacing the sodium ions in the original sample with cerium and the weight percent added are 0.35, 0.64, and 1.06 respectively. The effects of cerium loading to zeolite Y in different weight percent on the cracking catalysts were studied by employing a laboratory fluidized

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 15 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Ceramic Thickness and Number of Firings on the Color of Two All-Ceramic Systems Measured by Spectrophotometer
...Show More Authors

Background: This in vitro study was carried out to evaluate the effects of various veneering dentin ceramic thicknesses and repeated firings on the color of lithium disilicate glass-ceramic (IPS e.max Press) and zirconium-oxide (IPS ZirCAD) all-ceramic systems, measured by clinical spectrophotometers (Easyshade Advance 4.0) . Materials and methods: The 72specimens cube-shaped have the dimension of about 11 mm in width, 14 mm in length, 1mm in thickness, these cores divided into 3 groups according to the type of material each group have (24)core specimens. Each group had been divided into three sub-groups (each having 8 specimens) according to veneering with dentin ceramic thicknesses: as 0.5, 1, or 2 mm (n=8). IPS e.max press and ZirCAD c

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Plant Archives
Effect of sedimentation source on the nature occurrence and distribution of the feldspar in some soil of Alluvial plain Iraq
...Show More Authors

The current study was conducted to find out the effect of the sediment source (sedimentary of Iraqi-Iranian borderline and Tigris River) on the content and distribution of feldspar minerals and their effect on the optical properties of these minerals in some soils of Wasit and Maysan province. Eight pedons were chosen to represent the study area, five of them represented sediments coming from the borderline, which included pedons of (Badra, Taj Al-Din, Al-Shihabi, Jassan, and Galat), while two of them represent the sediments of the Tigris River (Essaouira, Al-Dabouni). Finally, the pedon of Ali Al-Gharbi represented the mixing area of sediments of all the torrents coming from borderline and the sediments of the Tigris River. The diagnostic

... Show More
Scopus (3)
Scopus
Publication Date
Wed Apr 01 2020
Journal Name
Plant Archives
Effect of applying selenium element and ascorbic acid on reducing the harmful effect of environmental stress on wheat plants irrigated by water contaminated with lead and cadmium
...Show More Authors

Scopus (4)
Scopus
Publication Date
Sat Oct 01 2011
Journal Name
Iraqi Journal Of Physics
A Study of the mechanical properties of aluminum composite materials prepared by atomization process
...Show More Authors

Steel fiber aluminum matrix composites were prepared by atomization technique. Different air atomization conditions were considered; which were atomization pressure and distance between sample and nozzle. Tensile stress properties were studied. XRF and XRD techniques were used to study the primary compositions and the structure of the raw materials and the atomized products. The tensile results showed that the best reported tensile strength observed for an atomization pressure equal to 4 mbar and sample to nozzle distance equal to 12 cm. Young modulus results showed that the best result occurred with an air atomization pressure equal to 8 mbar and sample to nozzle distance equal to 16cm

View Publication Preview PDF
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
The Effect of Anesthesia on Thyroid Hormones and Cortisol Levels Following Major Urological Surgery
...Show More Authors

This study was designed to evaluate the effect of anesthesia on thyroid hormones (T3, T4, rT3), thyrotropin(TSH), and cortisol levels in patients undergoing major urological surgery. The study included fifty patients scheduled for elective major urological surgery where 70% of the patients underwent general anesthesia, while30% underwent regional anesthesia. All patients were in stable control general conditions. The study showed that the thyroid hormones, thyrotropin and cortisol levels were affected with general anesthesia more than regional. The levels of these hormones responded to anesthetics and surgical stresses. This response was thought to be mainly mediated by afferent neurogenic impulses from the area of injury. Therefore, ab

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref