Preferred Language
Articles
/
nRbuJIcBVTCNdQwCEjrg
ON THE REDUCTION OF PRESTRESSING FORCE NEAR SUPPORTS IN PARTIALLY PRESTRESSED CONCRETE FLEXURAL MEMBERS
...Show More Authors

Straight tendons in pretensioned members can cause high-tensile stresses in the concrete extreme fibers at end sections because of the absence of the bending stresses due to self-weight and superimposed loads and the dominance of the moment due to prestressing force alone. Accordingly, the concrete tensile stresses at the ends of a member prestressed with straight tendons may limit the service load capacity of the member. It is therefore important to establish limiting zone in the concrete section within which the prestressing force can be applied without causing tension in the extreme concrete fibers. Two practical methods are available to reduce the stresses at the end sections due to the prestressing force. The first method based on changing the eccentricity of some tendons by raising them towards the end zone. The second method is based on bond prevention by encasing some of the tendons in plastic sheathing, effectively moving the point of application of prestressing force inward toward midspan for part of tendons. The present study focuses on a proposed third method to reduce the effect of the prestressing force near end supports by using straight strands with limited initial prestressing value in compression zone. New equations were suggested for the cracking moment and the prestressing force which consider the prestressed tendons in compression zone.

Crossref
View Publication
Publication Date
Mon Mar 27 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Experimental study of natural convection heat transfer on an enclosure partially filled porous medium heated from below by constant heat flux
...Show More Authors

This study reports on natural convection heat transfer in a square enclosure of length (L=20 cm) with a saturated porous medium (solid glass beads) having same fluid (air) at lower horizontal layer and free air fill in the rest of the cavity's space. The experimental work has been performed under the effects of heating from bottom by constant heat flux q=150,300,450,600 W/m2 for four porous layers thickness Hp (2.5,5,7.5,1) cm and three heaters length δ(20,14,7) cm. The top enclosure wall was good insulated and the two side walls were symmetrically cooled at constant temperature. Four layers of porous media with small porosity, Rayleigh number range (60.354 - 241.41) and (Da) 3.025x10-8 has been investigated. The obtained data of temperatu

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Wed Oct 05 2022
Journal Name
Heat Transfer
Numerical investigation of natural convection in a square enclosure partially filled with horizontal layers of a porous medium
...Show More Authors
Abstract<p>Two‐dimensional buoyancy‐induced flow and heat transfer inside a square enclosure partially occupied by copper metallic foam subjected to a symmetric side cooling and constant heat flux bottom heating was tested numerically. Finite Element Method was employed to solve the governing partial differential equations of the flow field and the Local Thermal Equilibrium model was used for the energy equation. The system boundaries were defined as lower heated wall by constant heat flux, cooled lateral walls, and insulated top wall. The three parameters elected to conduct the study are heater length (7 ≤ <italic>ζ</italic> ≤ 20 cm), constant heat flux (150 ≤ <italic>q<</italic></p> ... Show More
View Publication
Scopus (9)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Mon Apr 21 2025
Journal Name
Structural Concrete
On the effectiveness of shear reinforcement type in <scp>GFRP</scp>‐reinforced concrete beams: Experimental study
...Show More Authors
Abstract<p>This study investigated the shear performance of concrete beams with GFRP stirrups vs. traditional steel stirrups. Longitudinal glass fiber‐reinforced polymer (GFRP) bars were used to doubly reinforce the tested beams at both the top and bottom of their cross sections. To accomplish this, several stirrup spacings were provided. Eight beam specimens, measuring 300 × 250 × 2400 mm, were used in an experimental program to test under a two‐point concentrated load with an equal span‐to‐depth ratio until failure. Four beams in Group I have standard mild steel stirrups of 8 mm diameter, while four beams in Group II have GFRP stirrups with the same adopted diameter. The difference betwe</p> ... Show More
View Publication
Scopus (19)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Mon Apr 21 2025
Journal Name
Structural Concrete
On the effectiveness of shear reinforcement type in <scp>GFRP</scp>‐reinforced concrete beams: Experimental study
...Show More Authors
Abstract<p>This study investigated the shear performance of concrete beams with GFRP stirrups vs. traditional steel stirrups. Longitudinal glass fiber‐reinforced polymer (GFRP) bars were used to doubly reinforce the tested beams at both the top and bottom of their cross sections. To accomplish this, several stirrup spacings were provided. Eight beam specimens, measuring 300 × 250 × 2400 mm, were used in an experimental program to test under a two‐point concentrated load with an equal span‐to‐depth ratio until failure. Four beams in Group I have standard mild steel stirrups of 8 mm diameter, while four beams in Group II have GFRP stirrups with the same adopted diameter. The difference betwe</p> ... Show More
Scopus (19)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Tue Feb 05 2019
Journal Name
Journal Of The College Of Education For Women
Measures of the British Force in Iraq and their managements to limitate the pread of Malaria among its troops (Documentary Study)
...Show More Authors

Historical scripts and Academic studies have bestrewed almost all the events of the movement of march 1941 . Yet the need was present to shine more light on important sides . These important sides were neglected due to some reasons among which came the absence of the historical material which can make a new historical detection. Then there were historical topics concerning our research which comes within context of sanitarily conditions , rarely seizes the attention of the researchers for many reasons some of them were not subjective.
The spread of Malaria among the British force was one of the sanitarily conditions that were related to the movement of march since their arrival to Basra city and its continuous spread after the second

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 01 2016
Journal Name
Journal Of Engineering
Experimental Investigations on the Strength and Serviceability of Biaxial Hollow Concrete Slabs
...Show More Authors

Biaxial hollow slab is a reinforced concrete slab system with a grid of internal spherical voids included to reduce the self-weight. This paper presents an experimental study of behavior of one-way prestressed concrete bubbled slabs. Twelve full-scale one-way concrete slabs of (3000mm) length with rectangular cross-sectional area of (460mm) width and (150mm) depth. Different parameters like type of specimen (solid or bubbled slabs), type of reinforcement (normal or prestress), range of PPR and diameter of plastic spheres (100 or 120mm) are considered. Due to the using of prestressing force in bubbled slabs (with ratio of plastic sphere diameter D to slab thickness H, D/H=0.67), the specimens showed an increase in ultimat

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 12 2026
Journal Name
Mustansiria Dental Journal
Bite force in Iraqi children in relation to teeth contact and mandibular incisors angulation
...Show More Authors

View Publication
Publication Date
Fri Aug 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Natural Convection Heat Transfer in an Inclined Open-Ended Square Cavity with Partially Active Side Wall
...Show More Authors

This paper reports a numerical study of flow behaviors and natural convection heat transfer characteristics in an inclined open-ended square cavity filled with air. The cavity is formed by adiabatic top and bottom walls and partially heated vertical wall facing the opening. Governing equations in vorticity-stream function form are discretized via finite-difference method and are solved numerically by iterative successive under relaxation (SUR) technique. A computer program to solve mathematical model has been developed and written as a code for MATLAB software. Results in the form of streamlines, isotherms, and average Nusselt number, are obtained for a wide range of Rayleigh numbers 103-106 with Prandtl number 0.71

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Engineering
Finite Element Analysis of Cracked One-Way Bubbled Slabs Strengthened By External Prestressed Strands
...Show More Authors

Bubbled slabs can be exposed to damage or deterioration during its life. Therefore, the solution for strengthening must be provided. For the simulation of this case, the analysis of finite elements was carried out using ABAQUS 2017 software on six simply supported specimens, during which five are voided with 88 bubbles, and the other is solid. The slab specimens with symmetric boundary conditions were of dimensions 3200/570/150 mm. The solid slab and one bubbled slab are deemed references. Each of the other slabs was exposed to; (1) service charge, then unloaded (2) external prestressing and (3) loading to collapse under two line load. The external strengthening was applied using prestressed wire with four approaches, wh

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu May 05 2022
Journal Name
Al-kindy College Medical Journal
Awareness Regarding Diabetes Risk Factors, Prevention and Management among Community Members in Diyala/Baqubah
...Show More Authors

Background: Background: Diabetes mellitus is a life-threatening disease. Global prevalence of diabetes mellitus is increasing rapidly providing a worrying indication and major threat to global health unless interventions are created through community awareness and knowledge regarding different aspect of DM.

Aims: To assess the level of awareness regarding diabetes risk factors, prevention and management among community members in Baqubah city and to identify any association between awareness level and some variables.

Methods: Across sectional study was carried out from the 1st of January - 30th of November 2019 in all primary health care centers (six centers) in center of Baqubah city. A convenien

... Show More
View Publication Preview PDF
Crossref (3)
Crossref