Plasma generated by a 1064 nm pulsed Nd: YAG laser with pulse duration of 10 ns concentrated onto an Al solid target under vacuum pressure was examined spectroscopically. The temperature and electron density specifying the plasma were measured by time-resolved spectroscopy of neutral atom and ion line emissions in the time period range of 300–2000 ns. An echelle spectrograph is utilized to appear the plasma emission lines. The temperature was obtained using the spectral line comparison method and the electron density was calculated using the Stark Broadening (SB) method. The electron density was characterized as a function of laser pulse energy. The time range where the plasma is optically thin and is also in local thermodynamic equilibrium (LTE), significant for the laser-produced plasma (LPP) which was evaluated from the temporal profile of the intensity ratio of two Al I lines (λ1=380.581nm, 398.014nm, and 393.1996nm), (λ2= 586.781nm). It is found to be 700–1000 ns.
Background: Drawing blood to measure total serum bilirubin is painful & time consuming. Transcutaneous bilirubinometer working by multiwavelength spectral reflectance from the skin surface on forehead or upper sternum is a quick & painless technique. Objectives: to compare the effectiveness of transcutaneous (over the upper sternum and forehead) and serum bilirubin measurement of neonate with jaundice. Subjects and Methods: This is a cross sectional prospective study. It enrolled 175 jaundiced neonates & excluded those exposed to phototherapy. It was conducted at Child Central Teaching Hospi |
Purpose: To compare the central corneal thickness (CCT),minimum corneal thickness (MCT) and corneal power measured using theScheimpflug-Placido device and optical coherence tomography (OCT) in healthy eyes. Study Design: Descriptive observational. Place and Duration of Study: Al-Kindy college of medicine/university of Baghdad, from June 2021 to April 2022. Methods: A total of 200 eyes of 200 individuals were enrolled in this study. CCT and MCT measurements were carried out using spectral-domain optical coherence tomography (Optovue) and a Scheimpflug-Placido topographer (Sirius).The agreement between the two approaches was assessed using Bland-Altman analysis in this study. Results: Mean age was 28.54 ± 6.6 years, me
... Show MoreOur country suffered from pollution translation as a result to the wars events, so, it is necessary to measure the amount of radiation in the fields that are of indirect contact with human life and health. The main aim of the present work is to measure the concentration of alpha emitters in tomato fruits collected from different farms in Al – Basra governorate in the south of Iraq. Nuclear track detectors of type CR – 39 are used as a detection device and Can technique as a detection technique. Results show that the maximum concentration recorded is sample no.7 of site Al – Rafidhya which was equal to (6.9621 ± 0.111) ppm and sample no.1 of site Lothan with concentration equals to (4.9236 ± 0.117) ppm. The minimum concentratio
... Show MoreCeliac disease (CD) is the most common genetically - based disease in correlation with food intolerance. The aim of this study is to measure the activity of ALT enzyme and purify enzyme from sera women with celiac disease. Alanine aminotransferase (ALT) activity has been assayed in (30) women serum samples with celiac disease, age range between (20-40) year and (30) serum of healthy women as control group, age range between (22-38) year. In the present study, the mean value of ALT activity was significantly higher in patients with celiac disease than healthy group (p<0.01). The ALT enzyme was partial purified from sera women with celiac disease by dialysis, gel filtration using Sephadex G- 50 and ion exchange chromatography using DEAE- cell
... Show MoreAbstract: The aim of the present work is to measure radon concentration in wood. Solid state nuclear track detectors of type CR – 39 was used as measurement device. Eight different samples of imported and local wood were collected from markets. Samples were grinded, dried in order to measure radon concentrations in it. Cylindrical diffusion tube was used as detection technique. Results show that the higher concentration was in Iraqi sample 1 which recorded (14.02 ± 0.9) Bq / m3, while the less was in Emirates Sample which recorded (5.35 ± 1.2) Bq / m3. From the present work, all wood samples were with lowest concentrations of radon gas than other building materials.
Celiac disease (CD) is the most common genetically - based disease in correlation with food intolerance. The aim of this study is to measure the activity of ALT enzyme and purify enzyme from sera women with celiac disease. Alanine aminotransferase (ALT) activity has been assayed in (30) women serum samples with celiac disease, age range between (20-40) year and (30) serum of healthy women as control group, age range between (22-38) year. In the present study, the mean value of ALT activity was significantly higher in patients with celiac disease than healthy group (p<0.01). The ALT enzyme was partial purified from sera women with celiac disease by dialysis, gel filtration using Sephadex G- 50 and ion exchange chr
... Show MoreThe study was conducted to measure diatom species diversity in the lotic ecosystem across the Wasit Province for 12 months. The quantitative study of diatoms (phytoplankton) was investigated in the Tigris river. The density of algae was ranged from 60989 cell×103/l to 112780.82 cell×103/l in the five sites. These algae were belonging to 39 genera. The richness index values ranged from 1.53 at site 5 in January 2016 to 6.34 at site 1 and June2015. Shannon-Weiner diversity index (H´) was 2.33 in February 2016 and 3.72 in June 2015 both values at site 3, whereas Evenness index was 0.54 at site 5 in March2016 and 0.98 at site 1 in both August2015 and May2016. The lack of homogeneity of the appearance of species indicates the dominance of a
... Show MoreOptical properties of Rhodamine-B thin film prepared by PLD
technique have been investigated. The absorption spectra using
1064nm and 532 nm laser wavelength of different laser pulse
energies shows that all the curves contain two bands, B band and Q
bands with two branches, Q1 and Q2 band and a small shift in the
peaks location toward the long wavelength with increasing laser
energy. FTIR patterns for Rhodamine-B powder and thin film within
shows that the identified peaks were located in the standard values
that done in the previous researches. X-ray diffraction patterns of
powder and prepared Rhodamine-B thin film was display that the
powder has polycrystalline of tetragonal structure, while the thin film
Lasers, with their unique characteristics in terms of excellent beam quality, especially directionality and coherency, make them the solution that is key for many processes that require high precision. Lasers have good susceptibility to integrate with automated systems, which provides high flexibility to reach difficult zones. In addition, as a processing tool, a laser can be considered as a contact-free tool of precise tip that became attractive for high precision machining at the micro and nanoscales for different materials. All of the above advantages may be not enough unless the laser technician/engineer has enough knowledge about the mechanism of interaction between the laser light with the processed material. Several sequential phenom
... Show More