Background: This study evaluates transdermal delivery of tamoxifen (TXN) as an alternative to the oral route of administration in treating breast cancer, which is the leading cause of cancer-related death in women globally. Oral TXN, a Class II drug, is associated with first-pass metabolism and serious side effects, including secondary cancers. Objectives: To enhance transdermal delivery, lipid-based transethosomes (TRS) were formulated using three different 24 factorial designs with various non-ionic surfactants, including Tween 20®, Span 20®, and Span 80®. Methods: Optimized TRS formulations were incorporated into HPMC-based gels and characterized for morphology, drug content, pH, viscosity, spreadability, ex vivo skin penetration, and deposition. Additionally, cytotoxicity and stability were assessed. Results: All TXN-TRS gels were suitable for transdermal use; however, Span 20®-based TRS gel demonstrated the highest skin penetration (40.3 ± 1.5 µg/cm2), representing a 127-fold enhancement rate compared with the non-ethosomal TXN gel. In line with the enhanced penetration profile, cellular studies on MCF-7 cells showed concentration-dependent cytotoxicity, reaching 91.24 ± 1.01% inhibition at 2% w/w after 72 h, with an IC50 value of 0.85 ± 0.02% w/w. Stability testing showed all formulations were more stable under refrigeration than at dry room temperature storage, supporting their potential as preclinical transdermal tamoxifen delivery platforms. Conclusions: Span 20®-based TXN transethosomal gel markedly enhanced skin penetration while maintaining potent cytotoxic activity, supporting its further preclinical evaluation as a promising transdermal alternative to oral tamoxifen.
In this work, the design and implementation of a smart energy metering system has been developed. This system consists of two parts: billing center and a set of distributed smart energy meters. The function of smart energy meter is measuring and calculating the cost of consumed energy according to a multi-tariff scheme. This can be effectively solving the problem of stressing the electrical grid and rising consumer awareness. Moreover, smart energy meter decreases technical losses by improving power factor. The function of the billing center is to issue a consumer bill and contributes in locating the irregularities on the electrical grid (non-technical losses). Moreover, it sends the switch off command in case of the consumer bill is not
... Show MoreAzo dyes like methyl orange (MO) are very toxic components due to their recalcitrant properties which makes their removal from wastewater of textile industries a significant issue. The present study aimed to study their removal by utilizing aluminum and Ni foam (NiF) as anodes besides Fe foam electrodes as cathodes in an electrocoagulation (EC) system. Primary experiments were conducted using two Al anodes, two NiF anodes, or Al-NiF anodes to predict their advantages and drawbacks. It was concluded that the Al-NiF anodes were very effective in removing MO dye without long time of treatment or Ni leaching at in the case of adopting the Al-Al or NiF-NiF anodes, respectively. The structure and surface morphology of the NiF electrode were inves
... Show MoreThis study concerns the role of activated carbon (AC) from palm raceme as a support material for the enhancement of lipase-catalyzed reactions in an aqueous solution, with deep eutectic solvent (DES) as a co-solvent. The effects of carbonization temperature, impregnation ratio, and carbonization time on lipase activity were studied. The activities of Amano lipase from Burkholderia cepacia (AML) and lipase from the porcine pancreas (PPL) were used to investigate the optimum conditions for AC preparation. The results showed that AC has more interaction with PPL and effectively provides greater enzymatic activity compared with AML. The optimum treatment conditions of AC samples that yield the highest enzymatic activity were 0.5 (NaOH (
... Show MoreThis paper proposes a new structure for a Fractional Order Sliding Mode Controller (FOSMC) to control a Twin Rotor Aerodynamic System (TRAS). The new structure is composed by defining two 3-dimensional sliding mode surfaces for the TRAS model and introducing fractional order derivative integral in the state variables as well as in the control action. The parameters of the controller are determined so as to minimize the Integral of Time multiplied by Absolute Error (ITAE) performance index. Through comparison, this controller outperforms its integer counterpart in many specifications, such as reducing the delay time, rise time, percentage overshoot, settling time, time to reach the sliding surface, and amplitude of chattering in control inpu
... Show MoreLowering the emission, fuel economy and torque management are the essential
requirements in the recent development in the automobile industry. The main engine control
input that satisfies the above requirements is the throttling angle which adjusts the air mass
flow rate to the engine port. Due to the uncertainty and the presence of the nonlinear
components in its dynamical model, the sliding mode control theory is utilized in this work
for the throttle valve angle control system to design a robust controller for this system in the
presence of a nonlinear spring and Coulomb friction. A continuous sliding mode control law
which consists of a saturation function, instead of a signum function, and the integral of
ano