Preferred Language
Articles
/
nBjKFZgBVTCNdQwCyap6
An evaluation of water absorption of Giomer in comparison to other resin-based restorative materials
...Show More Authors

Background: Polymeric composites have been widely used as dental restorative materials. A fundamental knowledge and understanding of the behavior of these materials in the oral cavity is essential to improve their properties and performance. The goal of this study was to measure water sorption of four composite resins containing different filler and resin matrix contents. Materials and method: Resin composite specimens giomer (Beautifil II) Filtek™ P90, Filtek™ Z350 XT, and Tetric N Ceram were prepared in a cylindrical mould of 3mm thickness and 6mm diameter (n=10) and light cured . All specimens placed in silica-gel desiccators at 37˚C for seven days, a constant weight was obtained. All samples were immersed in deionized distilled water at 37˚C and weighed at suitable time interval once a week for 30 days. Water sorption was calculated based on ISO 4049. Data were subjected to student t- test. Results: Silorane and Giomer composites showed the lowest values of water sorption, while Z350 and Tetric N-Ceram displayed the highest values at a period of 4 weeks. Conclusion: Each resin- matrix composite varied in water sorption which may affect clinical service. The attained water sorption values are mainly influenced by the generic type of material and variations occurring between materials of the same type may result from differences in resin matrix compositions.

Publication Date
Wed Sep 01 2021
Journal Name
Iraqi Journal Of Physics
Study the Effect of Graphene on the Contact Angle, Water Absorption and Thermal Stability ( TGA ,DSC) for Blend (Epoxy & Repcoat ZR)
...Show More Authors

In this study, polymeric coating was developed by incorporating nano graphene in the polymer blend with applications to oil storage tanks. The oil storage tanks samples were brought from the oil Pipeline Company / Doura refinery in Baghdad. The coating polymer was formed with a blend (epoxy resin and repcoat ZR). The proportion of mixing the mixture was 3:1:1 epoxy resin 21.06 gm: repcoat ZR 10.53 gm: hardener 10.53 gm. The blend/graphene was prepared using in stui-polymerization method with different weight percentage 1, 3, 5, and 7 wt % added to blend. The resulting solution was put in a glass tube on a magnetic stirrer for one hour at a temperature of 40 °C. The result of contact angle and wate

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
An Ecological Observation on Inland water Ecosystem in Erbil –Iraq Kurdistan with particular reference to blue green algae Glaucospira
...Show More Authors

Regular sampling for six months from January to July 2012 were taken in small, shallow, perennial, standing ponds near the Greater Zab River, Gwer district, Erbil. A variety of physicochemical parameters were determined. Air and water temperature were falling between 15.2 - 34.7 ? C and 15.5 and 26.5 ?C. The waters are neutral (pH 7.38-8.27), hard, alkaline, salty, high in TDS and EC (892-966?S/cm, and rich in nutrients (NO3: 2.1-4.1mg/l, PO4: 0.33-0.62 mg / l , SO4: 24.7-80.2 mg / l ). The attention fixed on a filamentous blue- green algae Glaucospira Lagerheim, 1982) which is new to Iraqi flora. It is a filament (trichome), solitary, pale or yellowish blue – green, without sheath, Screw like coiled, motile, some of them are activ

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Dental Hypotheses
Effect of Amoxicillin and Azithromycin Suspensions on Microhardness of Sliver Reinforced and Nano Resin-Modified Glass Ionomers: An In Vitro Study
...Show More Authors

We aimed to examine the effect of amoxicillin and azithromycin suspensions on the microhardness of sliver-reinforced glass ionomer and nano-resin modified glass ionomer (GI). Method: Thirty discs (2mm height x 4mm diameter) of each type of GI were prepared, which were randomly assigned to amoxicillin, azithromycin, and artificial saliva groups. Microhardness was evaluated by Vickers hardness test before and after three immersion cycles. Results: The overall model (P < 0.001), before/after intervention (P < 0.001), intervention group (type of antibiotic) (P=0.013), and type of glass ionomer (P < 0.001) showed significant differences among study groups (P < 0.001). Post hoc test showed only non-significant before/after difference for Azithrom

... Show More
View Publication Preview PDF
Crossref (5)
Clarivate Crossref
Publication Date
Sun Feb 15 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of ginger extract on Mutans streptococci in comparison to chlorhexidine gluconate
...Show More Authors

Background: The rhizome of ginger is used in cooking and for medicinal purposes such as anti-bacterial, anti-fungal, anti-inflammatory and antioxidant. The aims of the study were to test the effect of ethanolic extract of ginger on growth, adherence and acidogenicity of mutans streptococci in comparison to chlorhexidine gluconate 0.2% and de-ionized water. Materials and methods: From saliva often volunteers (dental students 20-22 years); mutans streptococci was isolated, purified and diagnosed according to morphological characteristic and biochemical tests. Ginger was powdered and extracted, different concentrations of ginger extract were prepared. Chlorhexidine gluconate 0.2% used as a control positive; while de-ionized water was used as a

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 15 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of shear bond strength between thermosens as relining material and different denture base materials
...Show More Authors

Background: Denture relining is the process of resurfacing of the tissue side of the ill fitting denture, the bond strength at the relining-denture base interface is most important for denture durability.The aim of present study was to evaluate the shear bond strength between the thermosens as relining material and different denture base materials that bonded by thermo fusing liquid. As this corrective procedureis the common chair side procedure in the dental clinic. Material and method: Sixty samples were prepared and divided into three main groups according to the type of denture base materials.Group (A) referred to the heat cure acrylic samples which consisted of 20 samples. Group (B) referred to the high impact acrylic samples which con

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 15 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of silica layer on bonding strength of thermoplastic nylon to cold cure acrylic resin
...Show More Authors

Background: The combination of thermoplastic nylon resin materials and auto polymerizing resin is necessary in some situation for repair and adjustment. This study evaluated shear bond strength between thermoplastic nylon material (flexible) and auto polymerizing acrylic resin subjected to holes and silica coated layer. Materials and Method: Forty five (45) specimens were prepared from flexible acrylic bonded to auto-polymerizing acrylic resin and divided into three groups according to the surface treatments as follows: Group A: 15 specimens of flexible acrylic bonded with cold-cure acrylic by holes. Group B: 15 specimens of flexible acrylic bonded with cold-cure acrylic by silica coated layer. Group C: 15 specimens of flexible acrylic bon

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Fiber Laser Effect on Bond Strength of Titanium implant abutment to Resin Cement
...Show More Authors

Aim: surface modification of titanium using fiber laser 1064 nm to enhance the bond strength to resin cement. Material and Methods: thirty titanium discs of 0.6 cm x 0.3 cm (diameter and thickness respectively) were categorized after preparation into three groups (n=10) as follows: control group with no surface treatment and two test groups were treated with fiber laser after estimation the appropriate parameters in the pilot study which are 81 ns pulse duration, 30,000 Hz frequency, 50 µm spot size and 10,000 mm/s scanning speed and different average power values (10 W and 20 W) depending on the tested group. Titanium discs surface characterization was performed by scanning electron microscope (SEM), a

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 15 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Dissolution of calcium ion from teeth treated with different concentrations of siwak water extract in comparison with sodium fluoride
...Show More Authors

Background: The miswak is a teeth cleaning twig made from a twig of the Salvadora persica tree (known as arak in Arabic).A traditional alternative to the modern toothbrush, it has a long, well-documented history and is reputed for its medicinal benefits. It also features prominently in Islamic hygienical jurisprudence. Materials and methods: Twenty maxillary first premolars were treated with the selected solutions which included siwak water extract (5%, 10%) and sodium fluoride 0.05% for 2minutes once daily for 20 days interval, deionized water was used as control negative. Then the concentration of the dissolved calcium ion in the etching solution of 2N HCL was measured. Results: The least amount of the dissolved calcium ion was registere

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 05 2017
Journal Name
Https://www.researchgate.net/journal/international-journal-of-science-and-research-ijsr-2319-7064
Evaluation of Water Quality using Bhargava Water Quality Index Method and GIS, Case Study: Euphrates River in Al-Najaf City
...Show More Authors

ENGLISH

Crossref (3)
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Al-khwarizmi Engineering Journal
Applying Trade-off Curve to Support Set-Based Design application at an Aerospace Company
...Show More Authors

Companies compete greatly with each other today, so they need to focus on innovation to develop their products and make them competitive. Lean product development is the ideal way to develop product, foster innovation, maximize value, and reduce time. Set-Based Concurrent Engineering (SBCE) is an approved lean product improvement mechanism that builds on the creation of a number of alternative designs at the subsystem level. These designs are simultaneously improved and tested, and the weaker choices are removed gradually until the optimum solution is reached finally. SBCE implementations have been extensively performed in the automotive industry and there are a few case studies in the aerospace industry. This research describe the use o

... Show More
View Publication Preview PDF
Crossref (2)
Crossref