One of the critical factors for dental implant success is accurate clinical and radiological assessment. Cone-beam computed tomography systems (CBCT) allow surgeons to determine the quality and quantity before surgery, aiding in treatment planning. This study highlights the importance of such an assessment Materials and Methods A total of 40 patients were referred to CBCT scanning for pre-dental implant assessment in the Oral and Maxillofacial Radiology department at Al-Shaheed Gazi Al Hariri Hospital from 2021 to 2022. The patients were between 18 and 50 years old. All data were analyzed with on-demand 3D software (Kavo OP 3D: Cone Beam 3D imaging Germany). Results: Regarding the ridge shape: In the upper anterior and posterior regions, the rectangular shape had the highest percentages of (62.5%) and (75%) respectively. In the lower anterior and posterior regions, the pyramidal shape had the highest percentages of (55%) and (60%), respectively, and the hourglass shape was the lowest in all areas. Regarding bone density: The highest bone density percentage in the anterior upper region was D3 (67%), while in the upper posterior region, D4 had the highest percentage (77.5%). In the lower anterior region, D2 had a more prominent percentage (52.5%), while in the lower posterior, D3 was predominant (82.6%). Conclusion: From this study, it can be suggested that CBCT is the best modality for pre-implant radiographic assessment, and ridge shape and bone density are easily assessed using this method.
To evaluate impact the difference in stages ofage and related incidence of hemodialysis patients.Two hundred and fifty patients undergoing hemodialysis were collected from general hospital in Baghdad city /Iraq. The samples with renal failure before hemodialysis were divided into (138) male,( 112)female. The sera were separated from samples to physiological investigation. We found that renal failure was more predominant among the patients ages group ranging from (51-70) years old. The results shows A significant increase in the levels of urea, creatinine, in younger patients (≤ 30 years) when compared with older patients (>70 years). Furthermore a significant decrease in serum levels of total protein in patients in older patients (>7
... Show MoreBackground: Humeral diaphyseal fracture usually
heals with closed methods but when nonunion
develops then it needs surgical intervention in the
form of plating and bone grafting, intramedulary
nailing (open or closed simple or interlocking nails)
and external fixators (circular or one plane fixator).
In our unit we treated non union humeral
diaphyseal fracture with plating and bone grafting
shortening of fracture ends up to 4 to 5cm when
needed. Methods: This study was conducted at
Orthopaedic Department of AL-Sadar General
Hospital from January 2004 till December2005 .
We included 20 cases with atrophic non-union in
12(60%) and hypertrophic non-union in 8 (40%)
patients. All atrophic non-union w
A theoretical investigation is carried out to study the effect of a pencil electron beam propagating inside the plasma region determining the hydrodynamic densities distribution with the aid of numerical analysis finite deference method (FDM).The plasma is generated and trapped by annular electron beams of fixed electron density 1x1014 m-3. The result of the study shows that the hydrodynamic density behaves as the increase in pencil electron beam. The hydrodynamic density ratio goes to more than double as the increase in pencil electron beam density to 1x1018 m-3.
An analytical method and a two-dimensional finite element model for treating the problem of laser heating and melting has been applied to aluminum 2519T87and stainless steel 304. The time needed to melt and vaporize and the effects of laser power density on the melt depth for two metals are also obtained. In addition, the depth profile and time evolution of the temperature before melting and after melting are given, in which a discontinuity in the temperature gradient is obviously observed due to the latent heat of fusion and the increment in thermal conductivity in solid phase. The analytical results that induced by laser irradiation is in good agreement with numerical results.
Purpose: To compare the central corneal thickness (CCT),minimum corneal thickness (MCT) and corneal power measured using theScheimpflug-Placido device and optical coherence tomography (OCT) in healthy eyes. Study Design: Descriptive observational. Place and Duration of Study: Al-Kindy college of medicine/university of Baghdad, from June 2021 to April 2022. Methods: A total of 200 eyes of 200 individuals were enrolled in this study. CCT and MCT measurements were carried out using spectral-domain optical coherence tomography (Optovue) and a Scheimpflug-Placido topographer (Sirius).The agreement between the two approaches was assessed using Bland-Altman analysis in this study. Results: Mean age was 28.54 ± 6.6 years, me
... Show More