Preferred Language
Articles
/
n4ZjwoYBIXToZYALXrRT
PERFORMANCE OF SKIRTED CIRCULAR SHALLOW FOOTINGS RESTING ON SANDY SOIL UNDER INCLINED LOADS
...Show More Authors

Experimental tests were conducted to study the behavior of skirted foundations rested on dry medium sandy soil subjected to vertical and inclined loads. To achieve this goal, a small-scale physical model was designed and performed which contained an aluminum circular footing (100 mm) in diameter and (10 mm) in thickness and skirts with different heights, local medium poorly graded dry sand is placed in a steel soil container (2 mm) thick with internal dimensions (1000 mm x 1000 mm in cross section and 800 mm in height). The main objective of this study was to evaluate the response of skirt attached to the foundation at different skirt (L/D) ratios (0.0, 0.5, 1.0 and 1.5) and is subjected to point load at different angles of inclination (θ) (90 °, 80 °, 70 ° to 60 °) varying with the horizontal. In all tests, the relative density of sand was kept constant and equal to (60%). Four tests were conducted on a foundation without a skirt, for comparison reasons, and twelve tests were conducted on a skirt attached to foundation. The results showed that with decreasing the angle of inclination of load with the horizontal the load carrying capacity decreased due to increase the horizontal component of applied load which leads to increase the shear stresses under the foundation, however that effect decreases with increase the skirt height.

Crossref
View Publication
Publication Date
Thu Feb 27 2020
Journal Name
Iraqi Journal Of Science
Gene Expression of pelA and pslA in Pseudomonas Aeruginosa under Gentamicin Stress
...Show More Authors

     Pseudomonas aeruginosa produces an extracellular biofilm matrix that consists of nucleic acids, exopolysaccharides, lipid vesicles, and proteins. Alginate, Psl and Pel are three exopolysaccharides that constitute the main components in biofilm matrix, with many biological functions attributed to them, especially concerning the protection of the bacterial cell from antimicrobial agents and immune responses. A total of 25 gentamicin-resistant P. aeruginosa selected isolates were enrolled in this study. Biofilm development was observed in 96% of the isolates. In addition, the present results clarified the presence of pelA and pslA in all the studied isolates. The expression of these genes was very low. Even though all biof

... Show More
Crossref (6)
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Induction of antioxidant enzymes in wheat (Triticum spp.) grown under salt stress
...Show More Authors

A pot culture experiment was conducted at the greenhouse of soil and water resources department in College of Agriculture, University of Baghdad in Abo-Ghraib at season 2009-2010 to investigate the effects of using foliar application of some macro and micronutrients in induce antioxidant enzymes in wheat grown under salt stress . Doar85 planted under three levels of salt stress, and three combinations of foliar application were used from nutrients (K+ Ca) at 3000 and 1500 mg.L-1 respectively, and (Fe + Zn + Mn) at 30, 20, and 10 mg.L-1 respectively , and ( K+ Ca) + (Fe+ Zn + Mn). The results showed that increasing levels of sodium chloride in the irrigation of water significantly increased at p<0.05 level SOD and POD activity

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Different estimation methods of reliability in stress-strength model under chen distribution
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Sun May 01 2016
Journal Name
Journal Of Engineering
Experimental Behavior of Laced Reinforced Concrete One Way Slab under Static Load
...Show More Authors

Test results of eight reinforced concrete one way slab with lacing reinforcement are reported. The tests were designed to study the effect of the lacing reinforcement on the flexural behavior of one way slabs. The test parameters were the lacing steel ratio, flexural steel ratio and span to the effective depth ratio. One specimen had no lacing reinforcement and the remaining seven had various percentages of lacing and flexural steel ratios. All specimens were cast with normal density concrete of approximately 30 MPa compressive strength. The specimens were tested under two equal line loads applied statically at a thirds part (four point bending test) up to failure. Three percentage of lacing and flexural steel ratios wer

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 03 2017
Journal Name
Baghdad Science Journal
Photocatalytic degradation of indigo carmine by ZnO photocatalyst under visible light irradiation
...Show More Authors

In this work, the photocatalytic degradation of indigo carmine (IC) using zinc oxide suspension was studied. The effect of influential parameters such as initial indigo carmine concentration and catalyst loading were studied with the effect of Vis irradiation in the presence of reused ZnO was also investigated. The increased in initial dye concentration decreased the photodegradation and the increased catalyst loading increased the degradation percentage and the reused-ZnO exhibits lower photocatalytic activity than the ZnO catalyst. It has been found that the photocatalytic degradation of indigo carmine obeyed the pseudo-first-order kinetic reaction in presence of zinc oxide. This was found from plotting the relationship between ln

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (7)
Scopus Crossref
Publication Date
Fri May 01 2020
Journal Name
Journal Of Engineering
Punching Shear Behavior of Reinforced Concrete Slabs under Fire using Finite Elements
...Show More Authors

The main aim of this paper is studied the punching shear and behavior of reinforced concrete slabs exposed to fires, the possibility of punching shear failure occurred as a result of the fires and their inability to withstand the loads. Simulation by finite element analysis is made to predict the type of failure, distribution temperature through the thickness of the slabs, deformation and punching strength. Nonlinear finite element transient thermal-structural analysis at fire conditions are analyzed by ANSYS package. The validity of the modeling is performed for the mechanical and thermal properties of materials from earlier works from literature to decrea

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 11 2022
Journal Name
Journal Of The College Of Basic Education
Rationalization of two strength endurance tests for juniors Ages under (16) years
...Show More Authors

Carrying strength is one of the important physical capabilities in the field of competitive sports, which affects the success of the sports training process and helps players to continue to perform skillfully, physically and tactically for as long as possible, and the capacity for endurance varies depending on the type of sports activities, it may sometimes be very short. And with a high level of intensity, such as gymnastics and wrestling movements, and it may be long, and with a medium level of intensity, as in basketball, football and other games. The research community represents a sample of Baghdad players for teams (football, basketball, handball, volleyball, wrestling, weightlifting) and for the sports season (2017-2018 AD) for ages

... Show More
Publication Date
Tue May 16 2023
Journal Name
Steel And Composite Structures
Thermal buckling and stability of laminated plates under non uniform temperature distribution
...Show More Authors

Stability of laminated plate under thermal load varied linearly along thickness, is developed using a higher order displacement field which depend on a parameter “m”, whose value is optimized to get results closest to three-dimension elasticity results. Hamilton, s principle is used to derive equations of motion for laminated plates. These equations are solved using Navier-type for simply supported boundary conditions to obtain non uniform critical thermal buckling and fundamental frequency under a ratio of this load. Many design parameters of cross ply and angle ply laminates such as, number of layers, aspect ratios and E1/E2 ratios for thick and thin plates are investigated. It is observed that linear and uniform distribution of

... Show More
Publication Date
Tue Dec 29 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Electronic Payment System and its impact on the efficiency of the performance of banking: An applied research on a sample of banking sector in Iraq
...Show More Authors

The electronic payment systems are considered the most important infrastructure for the work of banks, particularly after a steady and remarkable development in information and communication technology, Which created the reality of the work of the infrastructure for these systems and these systems also become one of the most important components of infrastructure for the work of banks, cause it is one of the most important channels through which the transfer of cash, financial instruments between financial institutions in general and banking in particular.

     In order to achieve the objectives of the research, the most important to identify the concept of electronic payment systems, and its divisions, and th

... Show More
View Publication Preview PDF
Publication Date
Mon May 27 2019
Journal Name
Al-khwarizmi Engineering Journal
Effect of Using Air Guide Net in Front of the Condenser on the Performance of Automobile Air Conditioning System
...Show More Authors

 

The work of this paper is an investigation to improve the condenser performance of the automobile air conditioning system by enhancing the air-side heat transfer from the condenser through the use of an air guide net installed in front of the condenser face which is basically an aluminum plate having a circular entrance shape for the air passage.  The A/C system was examined under two types of test. The first test was conducted the air guide net, while the second was done with the air guide net. The performances of the A/C system under these tests were compared. For the second type of test, the experiment was carried out with three different size of air guide net, three different circular diameters (2, 3 and 3.5 cm) a

... Show More
View Publication Preview PDF
Crossref