Photovoltaic (PV) devices are widely used renewable energy resources and have been increasingly manufactured by many firms and trademarks. This condition makes the selection of right product difficult and requires the development of a fast, accurate and easy setup that can be implemented to test available samples and select the cost effective, efficient, and reliable product for implementation. An automated test setup for PV panels using LabVIEW and several microcontroller-based embedded systems were designed, tested, and implemented. This PV testing system was fully automated, where the only human intervention required was the instalment of PV panel and set up of required testing conditions. The designed and implemented system was characterized by high performance standard with accuracy, precision, and resolution that is good enough to practically test any PV panel of the 12 V and 24 V ratings. In this paper, several simulations run and manually performed testing for PV panels were done to verify the automatically obtained results and those were found to be of good conformity (-3% difference with simulation results, 0.01% with manually taken results).
Background: Selenium-73 with half- life of 7.15 hour emits β+ in nature and has six stable isotopes which are ( 74Se,76Se,77Se,78Se,80Se and 82Se ). Selenium-73 has many applications in technology and radioselenium compounds of metallic have found various applications in medicine. Objective: To make a comparison between different reactions that produced cross sections of Se-73 radioisotopes. Subjects and methods: The feasibility of the production of Selenium -73 via various nuclear reactions was investigated. Excitation functions of 73Se production by the reactions of 75As (p,3n), 169Tm( d,x), 74Se, natSe, natBr (p,x) , 75As (d,4n), natGe (3He,x), 70Ge (α, n), and 72Ge (α, 3n) and neutron capture were calculated using the avail
... Show MoreSingle-photon detection concept is the most crucial factor that determines the performance of quantum key distribution (QKD) systems. In this paper, a simulator with time domain visualizers and configurable parameters using continuous time simulation approach is presented for modeling and investigating the performance of single-photon detectors operating in Gieger mode at the wavelength of 830 nm. The widely used C30921S silicon avalanche photodiode was modeled in terms of avalanche pulse, the effect of experiment conditions such as excess voltage, temperature and average photon number on the photon detection efficiency, dark count rate and afterpulse probability. This work shows a general repeatable modeling process for significant perform
... Show MoreBackground: Bladder cancer (BC) is the most common malignant tumor in the urinary tract and the tenth most common malignancy worldwide. Exosomes are 40–100 nm-diameter nanovesicles that are either released straight from the plasma membrane during budding or merged with the plasma membrane by multivesicular bodies. Objectives: To assess the proportion of serum and urinary Exosome levels in urinary bladder cancer patients, as well as their impact on the disease. Methods: From January 2023 to June 2023, a total of 45 samples of blood and urine were collected from individuals diagnosed with bladder cancer at the Ghazi Hariri Hospital for Specialized Surgery. They included 45 male and female patients, varying in age, as well as 45 heal
... Show MoreThe gravity method is a measurement of relatively noticeable variations in the Earth’s gravitational field caused by lateral variations in rock's density. In the current research, a new technique is applied on the previous Bouguer map of gravity surveys (conducted from 1940–1950) of the last century, by selecting certain areas in the South-Western desert of Iraqi-territory within the provinces' administrative boundary of Najaf and Anbar. Depending on the theory of gravity inversion where gravity values could be reflected to density-contrast variations with the depths; so, gravity data inversion can be utilized to calculate the models of density and velocity from four selected depth-slices 9.63 Km, 1.1 Km, 0.682 Km and 0.407 Km.
... Show MoreThis paper compares between the direct and indirect georeferencing techniques in Photogrammetry bases on a simulation model. A flight plan is designed which consists of three strips with nine overlapped images for each strip by a (Canon 500D) digital camera with a resolution of 15 Mega Pixels.
The triangulation computations are carried out by using (ERDAS LPS) software, and the direct measurements are taken directly on the simulated model to substitute using GPS/INS in real case. Two computational tests have been implemented to evaluate the positional accuracy for the whole model and the Root Mean Square Error (RMSE) relating to (30) check points show that th
... Show MoreThe rivers are the main source of fresh water for many countries and the great development which is considered as one of the sustainable development elements in its various agricultural, industrial, domestic and environmental fields .The countries of the world seek food security and water security in order to ensure the basic needs of citizens .Because their distribution is uneven in many regions of the world with different human needs, which leads to conflicts over water sources, especially those located in one international river basin .This has led to the emergence of internationallegal rules governing the management of The problem revolves around the dialectic between limited water resources and increased need for water use b
... Show More