Photovoltaic (PV) devices are widely used renewable energy resources and have been increasingly manufactured by many firms and trademarks. This condition makes the selection of right product difficult and requires the development of a fast, accurate and easy setup that can be implemented to test available samples and select the cost effective, efficient, and reliable product for implementation. An automated test setup for PV panels using LabVIEW and several microcontroller-based embedded systems were designed, tested, and implemented. This PV testing system was fully automated, where the only human intervention required was the instalment of PV panel and set up of required testing conditions. The designed and implemented system was characterized by high performance standard with accuracy, precision, and resolution that is good enough to practically test any PV panel of the 12 V and 24 V ratings. In this paper, several simulations run and manually performed testing for PV panels were done to verify the automatically obtained results and those were found to be of good conformity (-3% difference with simulation results, 0.01% with manually taken results).
Background: During Annual statistical report published by the Iraqi ministry of health the year 2004 showed that mortality rate was 0.15 per 1000 of diarrheal episodes among children under five years.Objectives: To study the occurrence of Shigellosis and Entamoeba histolytica in a sample of children from certain hospitals in Baghdad and determine its relation to some demographic factors.Methods: This cross sectional study was carried out in Baghdad city involving 400 children with bloody diarrhea under five years of age attending four hospitals, 130 cases from Central Pediatric Hospital, 110 cases from Al Mansoor Pediatric Hospital, 90 cases from Al Kadhimya Teaching Hospital and 70 cases from Mohammed Baaqir Al Hakeem Hospital for the p
... Show MoreThis paper delves into some significant performance measures (PMs) of a bulk arrival queueing system with constant batch size b, according to arrival rates and service rates being fuzzy parameters. The bulk arrival queuing system deals with observation arrival into the queuing system as a constant group size before allowing individual customers entering to the service. This leads to obtaining a new tool with the aid of generating function methods. The corresponding traditional bulk queueing system model is more convenient under an uncertain environment. The α-cut approach is applied with the conventional Zadeh's extension principle (ZEP) to transform the triangular membership functions (Mem. Fs) fuzzy queues into a family of conventional b
... Show MoreThe corrosion of carbon steel in single phase (water with 0.1N NaCl ) and two immiscible phases (kerosene-water) using turbulently agitated system is investigated. The experiments are carried out for Reynolds number (Re) range of 38000 to 95000 corresponding to rotational velocities from 600 to 1400 rpm using circular disk turbine agitator at 40 0C. In two-phase system test runs are carried out in aqueous phase (water) concentrations of 1 % vol., 5 % vol., 8% vol., and 16% vol. mixed with kerosene at various Re. The effect of Reynolds number (Re), percent of dispersed phase, dispersed drops diameter, and number of drops per unit volume on the corrosion rate is investigated and discussed. Test runs are carried out using two types of
... Show MoreThe research aims to identify the importance of applying resource consumption accounting in the Iraqi industrial environment in general, and oil in particular, and its role in reducing the costs of activities by excluding and isolating idle energy costs, as the research problem represents that the company faces deficiencies and challenges in applying strategic cost tools. The research was based on The hypothesis that the application of resource consumption accounting will lead to the provision of appropriate information for the company through the allocation of costs properly by resource consumption accounting and then reduce the costs of activities. To prove the hypothesis of the research, the Light Derivatives Authority - Al-Dora Refin
... Show MoreFree vibration behavior was developed under the ratio of critical buckling temperature of laminated composite thin plates with the general elastic boundary condition. The equations of motion were found based on classical laminated plate theory (CLPT) while the solution functions consists of trigonometric function and a continuous function that is added to guarantee the sufficient smoother of the so-named remaining displacement function at the boundaries, in this research, a modified Fourier series were used, a generalized procedure solution was developed using Ritz method combined with the imaginary spring technique. The influences of many design parameters such as angles of layers, aspect ratio, thickness ratio, and ratio of initial in-
... Show MoreIn this study, the response and behavior of machine foundations resting on dry and saturated sand was investigated experimentally. A physical model was manufactured to simulate steady state harmonic load at different operating frequencies. The effect of relative density, depth of embedment, foundation area as well as the imposed harmonic load was investigated. It was found that the amplitude of displacement of the foundation increases with increasing the amplitude of dynamic force and operating frequency meanwhile it decreases with increasing the relative density of sand, degree of saturation, depth of embedment and contact area of footing. The maximum displacement was noticed at 33.34 to 41.67 Hz. The maximum displaceme
... Show MoreIn this paper, numerical and experimental studies on the elastic behavior of glass fiber reinforced polymer (GFRP) with stiffeners in the GFRP section's web (to prevent local buckling) are presented. The GFRP profiles were connected to the concrete deck slab by shear connectors. Two full-scale simply supported composite beams (with and without stiffeners) were tested under impact load (three-point load) to assess its structural response. The results proved that the maximum impact force, maximum deflection, damping time, and damping ratio of the composite beam were affected by the GFRP stiffeners. The experimental results indicated that the damping ratio and deflection were diminished compare
... Show MoreHypothyroidism has been associated with disorders of glucose and insulin metabolism..The present study was designed to evaluate the possible change in some hormones (free testosterone, estradiol, prolactin, insulin), glucose and homeostasis model assessment of insulin resistance (HOMA-IR) in women with primary hypothyroidism under thyroid hormone replacement therapy .This cross-sectional study was carried on 62 hypothyroid patients׳ women and 22 healthy women as control group at the specialized center for endocrinology and diabetes, AL-Rasafa Directorate of Health Baghdad, with age range(15-60 years), diagnosed as having primary hypothyroidism on thyroxine replacement therapy with duration not less than four months.
... Show MoreThis work investigates the effect of earthquakes on the stability of a collective pile subjected to seismic loads in the soil layer. Plaxis 3D 2020 finite element software modeled pile behavior in dry soils with sloping layers. The results showed a remarkable fluctuation between the earthquakes, where the three earthquakes (Halabja, El Centro, and Kobe) and the acceleration peak in the Kobe earthquake had a time of about 11 seconds. Different settlement results were shown, as different values were recorded for the three types of earthquakes. Settlement ratios were increased by increasing the seismic intensity; hence the maximum settlement was observed with the model under the effect of the Kobe earthquake (0.58 g), where
... Show MoreThe effect of applied current on protection of carbon steel in 0.1N NaCl solution (pH=7) was investigated under flow conditions (0-0.262 m/s) for a range of temperatures (35-55°C) using rotating cylinder electrode. Various values of currents were applied to protect steel from corrosion, these were Iapp.=Icorr., Iapp.=2Icorr. and Iapp.=2.4Icorr. under stationary and flow conditions. Corrosion current was measured by weight loss method. The variation of protection potential with time and rotation velocity at various applied currents was assessed. It is found that the corrosion rate of carbon steel increases with rotation velocity and
has unstable trend with temperature. The protection current required varies with temperature and it inc