The primary components of successful engineering projects are time, cost, and quality. The use of the ring footing ensures the presence of these elements. This investigation aims to find the optimum number of geogrid reinforcement layers under ring footing subjected to inclined loading. For this purpose, experimental models were used. The parameters were studied to find the optimum geogrid layers number, including the optimum geogrid layers spacing and the optimum geogrid layers number. The optimum geogrid layers spacing value is 0.5B. And as the load inclination angle increased, the tilting and the tilting improvement percent for the load inclination angles (5°,10°,15°) are (40%,28%, and 5%) respectively. The reduction percent of the lateral displacement for the spacing ratio (0.5B,0.75B,1B,1.25B) are (16%,10%,8%,7%), respectively. The optimum geogrid layers number is found to be 4. As the load inclination angle increased, the tilting and the tilting improvement percent for the load inclination angles (5°,10°,15°) are (45%,33%, and 8%), respectively. The reduction percent of the lateral displacement for the reinforcement layers number (1,2,3,4) are (12%,16%,18%,20%), respectively
There are two ways that the contract might be formed with (contracting between persons who are attended and contracting between absence persons).the need for determining the precise moment of the contract , is so clear because there is a specify period separate between the declaration of acceptance and the knowledge with it .and it is clear from the four theories known for jurisprudence (theory of the declaration of the acceptance, theory of exporting the acceptance , theory of the arrival of the acceptance , theory of the knowledge with the acceptance ) . It is difficult to promote one theory on another one if we look at each one and the justification of its supporters and what the opponents of each theory expose. Legal background and diff
... Show MoreThe present work is an attempt to develop design data for an Iraqi roof and wall constructions using the latest ASHRAE Radiant Time Series (RTS) cooling load calculation method. The work involves calculation of cooling load theoretically by introducing the design data for Iraq, and verifies the results experimentally by field measurements. Technical specifications of Iraqi construction materials are used to derive the conduction time factors that needed in RTS method calculations. Special software published by Oklahoma state university is used to extract the conduction factors according to the technical specifications of Iraqi construction materials. Good agreement between the average theoretical and measured cooli
... Show MoreThe problem of Multicollinearity is one of the most common problems, which deal to a large extent with the internal correlation between explanatory variables. This problem is especially Appear in economics and applied research, The problem of Multicollinearity has a negative effect on the regression model, such as oversized variance degree and estimation of parameters that are unstable when we use the Least Square Method ( OLS), Therefore, other methods were used to estimate the parameters of the negative binomial model, including the estimated Ridge Regression Method and the Liu type estimator, The negative binomial regression model is a nonline
... Show MoreA group of acceptance sampling to testing the products was designed when the life time of an item follows a log-logistics distribution. The minimum number of groups (k) required for a given group size and acceptance number is determined when various values of Consumer’s Risk and test termination time are specified. All the results about these sampling plan and probability of acceptance were explained with tables.
In drilling processes, the rheological properties pointed to the nature of the run-off and the composition of the drilling mud. Drilling mud performance can be assessed for solving the problems of the hole cleaning, fluid management, and hydraulics controls. The rheology factors are typically termed through the following parameters: Yield Point (Yp) and Plastic Viscosity (μp). The relation of (YP/ μp) is used for measuring of levelling for flow. High YP/ μp percentages are responsible for well cuttings transportation through laminar flow. The adequate values of (YP/ μp) are between 0 to 1 for the rheological models which used in drilling. This is what appeared in most of the models that were used in this study. The pressure loss
... Show MoreThe base of the ELWE MPF-1 microcomputer is the Z80 microprocessor. The Z80 programs are written in assembly language. The main advantage of assembly language is that: it is much faster to code and the mnemonics makes it easier for the user to remember the instruction. The purpose of this paper is to improve the monitor process for didactic microcomputer ELWE MPF-1 by appending new powerful commands (MOVE, FILL, SEARCH and COMPARE) to the existing monitor to make it more useful and flexible. 8085 assembly language is used to execute this program. The letters used for abbreviation: M for MOVE, F for FILL, S for SEARCH and C for COMPARE.
The research aims at showing the media awareness for Students, especially for the students of the preparatory schools through their following the mass media in forming the cultural, educational and political database. It also aims at building a content and prospectives that make them a wide awake stratum that safeguard the society which has faced huge effects of terrorist actions.
Furthermore, it aims at knowing to what extent that students have been acquainted with the printed and electronic newspapers. Finally, it aims at knowing to what extent that they are content with the mass media in covering and
... Show MoreThermal energy storage is an important component in energy units to decrease the gap between energy supply and demand. Free convection and the locations of the tubes carrying the heat-transfer fluid (HTF) have a significant influence on both the energy discharging potential and the buoyancy effect during the solidification mode. In the present study, the impact of the tube position was examined during the discharging process. Liquid-fraction evolution and energy removal rate with thermo-fluid contour profiles were used to examine the performance of the unit. Heat exchanger tubes are proposed with different numbers and positions in the unit for various cases including uniform and non-uniform tubes distribution. The results show that
... Show MoreFor the design of a deep foundation, piles are presumed to transfer the axial and lateral loads into the ground. However, the effects of the combined loads are generally ignored in engineering practice since there are uncertainties to the precise definition of soil–pile interactions. Hence, for technical discussions of the soil–pile interactions due to dynamic loads, a three-dimensional finite element model was developed to evaluate the soil pile performance based on the 1 g shaking table test. The static loads consisted of 50% of the allowable vertical pile capacity and 50% of the allowable lateral pile capacity. The dynamic loads were taken from the recorded data of the Kobe e