Aims: To assess the success rate and implant stability changes of narrow dental implants (NDIs) during the osseous healing period. Materials and methods: This prospective observational clinical study included 21 patients with narrow alveolar ridge of restricted mesiodistal interdental span who received NDIs. The alveolar ridge width was determined by the ridge mapping technique. Implant stability was measured using Periotest® M immediately after implant insertion then after 4 weeks, 8 weeks and 12 weeks postoperatively. The outcome variables were success rate and implant stability changes during the healing period. The statistical analysis included one-way analysis of variance (ANOVA) and Tukey\'s multiple comparisons test, values < 0.05 were considered statistically significant. Results: Twenty-one patients received 54 implants, the success rate was 92.6% (50/54). The mean ± SD periotest value (PTV) was significantly increased at 4 weeks (7.62 ± 6.39 PTV) compared with primary stability (1.48 ± 3.16 PTV), at 8 weeks (4.46 ± 4.45 PTV). It significantly decreased compared with that at 4 weeks and at 12 weeks (1.82 ± 3.22 PTV); it decreased significantly compared to that at 8 weeks. Conclusion: Narrow dental implants have a high early success rate. The implant stability during the healing period drops significantly in the first 4 weeks postoperatively and then increases steadily in the following weeks to reach to a level close to that of primary stability after 12 weeks. Clinical significance: Narrow dental implants are indicated in cases of insufficient alveolar bone width obviating the need for bone augmentation and reduced interdental space such as in cases of congenitally missing teeth or after orthodontic treatment. Knowledge of the stability changes during the osseous healing period enables the clinicians to determine the optimum time for functional loading.
The article describes a study on the role of vitamin C as a protective agent for the teeth, gum, and implants using quantum chemical calculations and polarization tests. The Density Functional Theory (DFT) at 6-311G (d, p) basis set is used to estimate the ability of vitamin C to inhibit the corrosion of the abovementioned parts. The experimental study was performed in a at human body media simulator (Hank’s balanced salt solution) at a temperature of 37°C. The compound was optimized for its ground state, physical properties, and corrosion parameters. Further, HOMO, LUMO, energy gap, dipole moment, and other parameters were used to predict the inhibitor’s efficiency. Gaussian 09, UCA-FUKUI, MGL tools, DSV, and LigPlus software was used
... Show MoreBackground: In the traditional protocol, the patient should wait after extraction up to six months to place the dental implant in healed bone, this waiting time accompanied by varying degrees of alveolar bone changes. In order to overcome these problems, immediate implant placement in the fresh extraction socket was introduced. The Aim of this study was to evaluate the outcome of the immediate implant placement utilizing Resonance Frequency Analysis (RFA) to quantify implant stability and osseointegration. Materials and Methods: A total of (23) patients participated in the study, receiving (44) implants placed in the sockets of teeth indicated for extraction. Clinical and radiographic preoperative assessment was accomplished for each patie
... Show MoreIn this paper, we investigate and study quantum theoretical of quark-gluon interaction modeling in QGP matter formatted. In theoretical modeling, we can use a flavor number, strength coupling, critical energy Tc = 190 MeV, system energy (400-650)MeV, fugacity of quark and gluon, and photon energy in range of 1-10 GeV parameter to calculation and investigation spectrum of photon rate. We calculation and study the photon rate produced through bremsstrahlung processes from the stable QGP matter. The photon rate production from cg → dgy systems at bremsstrahlung processes are found to be increased with increased fugacity, decreased strength coupling, decreased the photons energy and temperature of system. The photons rate in cg → dgy is inc
... Show MoreBackground: Contact between implant material and bones must be strong and fast creation, to fulfill these properties appropriate surface modifications must apply on used implants. In this contribution; double surface modifications are applied on Ti-6Al-4V alloy to accelerate osseointegration. Materials and methods: Anodic process is utilized to create titania nanotubes (TNTs) on the screws made from Ti-6Al-4V alloy. These implants were coated with nano ZrO2 particles. Second modification was annealing anodized screws at 8000C, and implanted in tibiae of nine adult New Zealand white rabbits. Results: Physical and histological consequences of two surface modifications on Ti-6Al-4V alloy screws were studied. Scanning electron microscope (SEM)
... Show MoreBackground: Dental implant considers a unique treatment option for the replacement of missing dentition. The new trend of implants is looking for materials which accelerate bone formation in bone implant interface and enhance osseointegration to provide immediate loading directly after placement and decrease the time period which is disturbs patients and uncomfortable. The aim of the study was to evaluate the effect of nano zirconium oxide (ZrO2) and nano hydroxyapatite (Hap) mixture coating of screw shaped commercially pure titanium (cpTi) implants on bond strength at the bone implant interface with torque removal test and histological analysis in comparison with non coated implants. Materials and methods: Forty screws were machined from c
... Show MoreBackground: A case-control study design revealeda relationship between the present of fluoride, and the reduction of dental caries and the increase prevalence and severity of dental fluorosis .The aim of this study was to assess the prevalence and severity of dental caries in relation to dental fluorosis among school children in Al-Muthana'a Governorate. Materials and methods: It was conducted among primary school students aged 12 years old, the age was taken according to the criteria of World Health Organization (1997) (1).The number of students was selected in each sector of control group according to number of schools in that sector .Sectors of control group which depend on water of river as source of drinking water. Case group which inc
... Show MoreThree different types of nozzles (different wear rate) were used in this study. They are classified depending on the severity of their wear to three groups: new, worn and damaged nozzles. Those nozzles were spraying with the same application rate (303 l/ha) on two-year field trials; this was achieved by changing the spraying pressure for each group of nozzles in order to get the same application rate. This practice is usually done by operators of sprayers, who calibrate the sprayers on the same application rate every year without changing the nozzles, so they tend to reduce the spraying pressure in order to compensate the flow rate increase due to the nozzles yearly wear. Two types of
It reflects the gross domestic product in any country total output of goods and services by the size of the country's citizens and foreign residents during the period of the year and reflect the contribution of the commodity sectors of the economy and the distribution and service in the composition of output. And gross domestic product in Iraq as an indicator dominated in the composition of oil output, along with the contribution of the service sector, as the gross domestic product is the output of a yield lien and subjected GDP in Iraq to a series of declines succession due to vibrations of the oil market during the economic blockade on the one hand and stop imported production inputs, lack of arriving in commodity s
... Show More