Severe periodontitis is ranked as the sixth most prevalent disease affecting humankind, with an estimated 740 million people affected worldwide. The diagnosis of periodontal diseases mainly relies upon assessment of conventional clinical parameters. However, these parameters reflect past, rather than current, clinical status or future disease progression and, likely, outcome of periodontal treatment. Specific and sensitive biomarkers for periodontal diseases have been examined widely to address these issues and some biomarkers have been translated as point-of-care (PoC) tests. The aim of this review was to provide an update on PoC tests for use in the diagnosis and management of periodontal diseases. Among the PoC tests developed so far, active matrix metalloproteinase-8 has shown promising results in terms of diagnostic and prognostic values. However, further studies are required to increase the sensitivity and specificity via combining more than one biomarker and merging these test kits with periodontal risk assessment tools. Furthermore, the validity of these test kits needs to be investigated by applying the results in further independent studies and the impact on these test kits’, together with the results of risk factors for periodontal diseases, such as diabetes and smoking, also needs to be examined.
Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (o
... Show MoreCommercially pure titanium (cpTi) is widely used as dental implant material although it was found that titanium exhibited high modulus of elasticity and the lower corrosion tendency in oral environment. Niobium(Nb) was chosen for this study as an alternative to cpTi implant material due to its bioinert behavior and good elastic modulus and moderate cost in addition to corrosion resistance. This study was done to evaluate the effect of biomimetic coating on the surface properties of the commercially pure titanium and niobium implants by in vitro and in vivo experiments. The in vitro study was involved etching the samples of each material in HCl then soaking in 10M NaOH aqueous solution. These samples were then immersed in a 5 times concent
... Show MoreBackground: Gingival crevice fluid (GCF) is a mixture of substances derived from serum, leukocytes, and structural cells of periodontium and oral bacteria. These substances possess a great potential for serving as indicators of periodontal disease and healing after therapy the main purpose of this study was to find if there is a difference in albumin concentration between healthy and diseased periodontal tissues and to compare between diseased group according to pocket depth Materials and methods: total sample composed of 60 pockets found in 35 patients all of them had no history of any systemic disease, The samples were divided in to three main group that include two diseased groups divided according to the depth of the periodontal pocket
... Show MoreThis study aims to employ modern spatial simulation models to predict the future growth of Al-Najaf city for the year 2036 by studying the change in land use for the time period (1986-2016) because of its importance in shaping future policy for the planning process and decision-making process and ensuring a sustainable urban future, using Geographical information software programs and remote sensing (GIS, IDRISI Selva) as they are appropriate tools for exploring spatial temporal changes from the local level to the global scale. The application of the Markov chain model, which is a popular model that calculates the probability of future change based on the past, and the Cellular Automa
This paper investigates a new approach to the rapid control of an upper limb exoskeleton actuator. We used a mathematical model and motion measurements of a human arm to estimate joint torque as a means to control the exoskeleton’s actuator. The proposed arm model is based on a two-pendulum configuration and is used to obtain instantaneous joint torques which are then passed into control law to regulate the actuator torque. Nine subjects volunteered to take part in the experimental protocol, in which inertial measurement units (IMUs) and a digital goniometer were used to measure and estimate the torque profiles. To validate the control law, a Simscape model was developed to simulate the arm model and control law in which measurem
... Show MoreThis study aimed to identify the effect of resistance training on the biomechanics and accuracy of serve receiving skills in volleyball. The research community was composed of 26 young volleyball players of Baghdad volleyball clubs. A total of 4 players were selected for the preliminary experiment, while 14 participants were recruited as the main sample for the study. In the present study, a set of resistance exercises were designed by the researchers for the volleyball players of the sample. Exercises were performed by the sample participants during the course of study. The biomechanical variables considered in the present study were: Preparation moment (shoulder joint angle, hip angle, knee joint angle), moment of pr
... Show MoreABSTRACT Background: According to Branemark’s protocol, the waiting period between tooth extraction and implant placement is 6–8 months; this is the late placement technique. Achieving and maintaining implant stability are prerequisites for a dental implant to be successful. Resonance Frequency Analysis (RFA) is a noninvasive diagnostic method that measures implant stability. The aim of this study was to investigate the influence of treatment protocol and implant dimensions on primary implant stability utilizing RFA. Materials and methods: This study included 63 Iraqi patients (37 male, 26 female; ranging 22-66 years). According to treatment protocol, the sample was divided into 2 groups; A (delayed) & B (immediate). Dental im
... Show More