Preferred Language
Articles
/
mhbwUYoBVTCNdQwCBZTK
Adding PC Connectivity to the MTS-88 Microcomputer Teaching System
...Show More Authors

The MTS-88. c trainer is a training system targeting students in the microprocessors course. It has a built in single-line assembler allowing the users to enter programs in assembly. It has the problem that long programs cannot be traced and tested efficiently. A simple error may cause all the code to be erased and the system to stop responding. Also, this system lacks the ability to be connected to the PC. The aim of this work is to modify the system to make it possible to be connected to the PC through the parallel port. This gives the capability to download long programs to the system after being developed in the PC. The 8255 Programmable Peripheral Interface available in the teaching system is interfaced to the parallel port and used as communication channel between the PC and the system. Software on both parties is developed to handle the communication protocol.

Publication Date
Tue Dec 01 2020
Journal Name
Al-khwarizmi Engineering Journal
Remote Patient Healthcare surveillance system based real-time vital signs
...Show More Authors

Today many people suffering from health problems like dysfunction in lungs and cardiac. These problems often require surveillance and follow up to save a patient's health, besides control diseases before progression. For that, this work has been proposed to design and developed a remote patient surveillance system, which deals with 4 medical signs (temperature, SPO2, heart rate, and Electrocardiogram ECG. An adaptive filter has been used to remove any noise from the signal, also, a simple and fast search algorithm has been designed to find the features of  ECG signal such as Q,R,S, and T waves.  The system performs analysis for medical signs that are used to detected abnormal values. Besides, it sends data to the Base-Stati

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Tue Oct 01 2019
Journal Name
2019 Ieee 9th International Conference On System Engineering And Technology (icset)
A Digital Signature System Based on Real Time Face Recognition
...Show More Authors

This study proposed a biometric-based digital signature scheme proposed for facial recognition. The scheme is designed and built to verify the person’s identity during a registration process and retrieve their public and private keys stored in the database. The RSA algorithm has been used as asymmetric encryption method to encrypt hashes generated for digital documents. It uses the hash function (SHA-256) to generate digital signatures. In this study, local binary patterns histograms (LBPH) were used for facial recognition. The facial recognition method was evaluated on ORL faces retrieved from the database of Cambridge University. From the analysis, the LBPH algorithm achieved 97.5% accuracy; the real-time testing was done on thirty subj

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Jan 17 2023
Journal Name
International Journal Of Online And Biomedical Engineering (ijoe)
Private Backend Server Software-Based Telehealthcare Tracking and Monitoring System
...Show More Authors

In these recent years, the world has witnessed a kind of social exclusion and the inability to communicate directly due to the Corona Virus Covid 19 (COVID-19) pandemic, and the consequent difficulty of communicating with patients with hospitals led to the need to use modern technology to solve and facilitate the problem of people communicating with each other. healthcare has made many remarkable developments through the Internet of things (IOT) and cloud computing to monitor real-time patients' data, which has enabled many patients' lives to be saved. this paper presents the design and implementation of a Private Backend Server Software based on an IoT health monitoring system concerned emergency medical services utilizing biosenso

... Show More
View Publication
Scopus (30)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Wed Jan 28 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of a new orthodontic bonding system (Beauty Ortho Bond)
...Show More Authors

Background: The purpose of the current study was to evaluate the efficacy of a new orthodontic bonding system (Beauty Ortho Bond) involving the shear bond strength in dry and wet environments, and adhesion remnant index (ARI) scores evaluation in regard to other bonding systems (Heliosit and Resilience Orthodontic Adhesives). Materials and methods: Sixty defect free extracted premolars were randomly divided into six groups of 10 teeth each, mounted in acrylic resin, three groups for a dry environment and three for a wet one. Shear bond strength test was performed with a cross head speed of 0.5 mm/min, while surfaces of enamel and bracket-adhesive-enamel surfaces were examined with stereomicroscope For ARI scores evaluation. Data were analyz

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Journal Of Engineering Science And Technology
Membrane Fouling Reduction for Reverse Osmosis System Using Zeta Rod
...Show More Authors

Reverse osmosis membrane desalination is one of the most significant water treatments that is used to offer freshwater. The aim of this research is to study the effect of controlling the value of the zeta potential on the suspended particles in the water and the proximity of the membrane surfaces in the colloidal solution, to keep the water stable electrically and disperse the colloidal particles. To achieve this aim, the experimental study was conducted in the Sanitary Engineering Laboratory, in the engineering college - University of Baghdad. Two systems were set up, one worked normally and the other worked by using the zeta rod placed before the reverse osmosis membrane. The results showed that the effect of the zeta rod increas

... Show More
Publication Date
Thu Dec 28 2017
Journal Name
Al-khwarizmi Engineering Journal
Design of Robotic Arm Control System Mimics Human Arm Motion
...Show More Authors

This paper presents a control system to make the robotic hand mimic human hand motion in real time and offline mode. The human hand tracking system is a wearable sensing arm (potentiometers) used to determine the position in space and to sense the grasping task of human hand. The maskable sensing arm was designed with same geometrical arrangement of robotic hand that needs to be controlled. The control software of a robot was implemented using Visual Basic and supported with graphical user interface (GUI). The control algorithm depends on joint to joint mapping method to match between the motions at each joint of portable sensing arm with corresponding joint of a robot in order to make the robot mimic the motion.

View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Adaptive Sliding Mode Controller for Servo Actuator System with Friction
...Show More Authors

This paper addresses the use of adaptive sliding mode control for the servo actuator system with friction. The adaptive sliding mode control has several advantages over traditional sliding mode control method. Firstly, the magnitude of control effort is reduced to the minimal admissible level defined by the conditions for the sliding mode to exist. Secondly, the upper bounds of uncertainties are not required to be known in advance. Therefore, adaptive sliding mode control method can be effectively implemented. The numerical simulation via MATLAB 2014a for servo actuator system with friction is investigated to confirm the effectiveness of the proposed robust adaptive sliding mode control scheme. The results clarify, after

... Show More
View Publication Preview PDF
Publication Date
Thu May 25 2023
Journal Name
Eureka: Physics And Engineering
Design, analysis and construction of a simple pulse duplicator system
...Show More Authors

One of the most important human diseases that need to be considered in terms of development of the medical engineering devices is cardiovascular disease which is a significant cause of death globally recently. Valvular heart disease is normally treated by restoring or altering heart valves with an artificial one. But the new prosthetic valve designs necessitate testing for durability estimate and failure method. It is significant to simulate the circulation system by the building of a pulse duplicator system. This study is stated by clarifying the parameter and implementation steps of the pulse duplicator system in which the different researchers have utilized the system and tried to explain the design steps of using this system wit

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Experimental investigation of dusty plasma characteristics in AC discharge system
...Show More Authors

In the present work, the effect of size of zinc dust particles on
AC argon discharge characteristics are investigated
experimentally. The plasma characteristics are determined by
using optical emission spectroscopy (OES) techniques. The
results illustrated that the electron temperature (Te) in the present
and absent of Zinc dust particle is reduced with increasing of
pressure. The electron temperature decreases with increasing of
Zinc dust size. Excitation temperature Tex is reduces with
increasing of Ar pressure in present and absent of zinc dust
particles. The present of Zinc dust reduce the Tex of Ar in both
Zinc dust size. The electron density increasing in the present and
absent of both zinc dust siz

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 01 2019
Journal Name
Materials Science And Engineering
Effect of nanoparticles on thermal conductivity of epoxy resin system
...Show More Authors
Abstract<p>In this paper the effect of mixing TiO2 nanoparticles with epoxy resin is studied. The TiO2 nanoparticles would be synthesis and characterized by scanning electron microscopy (SEM), XRD FTIR, for two particle sizes of 50 and 25 nm. The thermal conductivity is measured with and without composite epoxy resin; the results showed that the thermal conductivity was increased as nanoparticle concentration increased too. The thermal conductivity was increased as particle size decreased.</p>
Preview PDF
Scopus (9)
Crossref (7)
Scopus Clarivate Crossref