Preferred Language
Articles
/
mhYKF4oBVTCNdQwCwpCm
Applying a suitable approximate-simulation technique of an epidemic model with random parameters
...Show More Authors

Because the Coronavirus epidemic spread in Iraq, the COVID-19 epidemic of people quarantined due to infection is our application in this work. The numerical simulation methods used in this research are more suitable than other analytical and numerical methods because they solve random systems. Since the Covid-19 epidemic system has random variables coefficients, these methods are used. Suitable numerical simulation methods have been applied to solve the COVID-19 epidemic model in Iraq. The analytical results of the Variation iteration method (VIM) are executed to compare the results. One numerical method which is the Finite difference method (FD) has been used to solve the Coronavirus model and for comparison purposes. The numerical simulation methods which are Mean Monte Carlo Finite difference (MMC_FD) and Mean Latin Hypercube Finite difference (MLH_FD), are also used to solve the proposed epidemic model under study. The obtained results are discussed, tabulated, and represented graphically. Finally, the absolute error is the tool used to compare the numerical simulation solutions from 2020 to 2024 years. The behavior of the Coronavirus in Iraq has been expected for 4 years from 2020 to 2024 using the proposed numerical simulation methods.

Publication Date
Mon May 01 2017
Journal Name
Ieee International Electrical Machines & Drives Conference Ieee (iemdc2017), Miami, Usa
The effect of power converter on the design of a Linear Alternator for use with a Joule Cycle-Free Piston Engine
...Show More Authors

Scopus (4)
Crossref (5)
Scopus Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Simulation Study on Optically Designed Refractive Beam Expander for Nd: YAG Laser Harmonics for 7 Km Detection Range
...Show More Authors

The simulation study has been conducted for the harmonics of Nd: YAG laser, namely the second harmonic generation SHG, the third harmonic generation THG, and the fourth harmonic generation FHG. Determination of beam expander's expansion ratio for specific wavelength and given detection range is the key in beam expander design for determining minimum laser spot size at the target. Knowing optimum expansion ratio decreases receiving unit dimensions and increases its performance efficiency. Simulation of the above mentioned parameters is conducted for the two types of refractive beam expander, Keplerian and Galilean. Ideal refractive indices for the lenses are chosen adequately for Nd: YAG laser harmonics wavelengths, so that increasing transm

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Acta Facultatis Medicae Naissensis
Operative treatment of femoral neck fractures with cannulated screws with and without platelet rich plasma in young adults: A comparative study
...Show More Authors

Many studies have evaluated the effect of platelet rich plasma (PRP) in the treatment of non-union fractures but few studies have investigated their effect on the union of femoral neck fractures or their functional outcome in young adults. The aim of this study was to evaluate the union time and functional outcome in young adult patients with femoral neck fracture managed by three cannulated screws injected with PRP and those managed by fixation only. This prospective study included 24 patients diagnosed with femoral neck fractures within 24 hours of presentation. Twelve cases in group A were managed by closed reduction and three cannulated screws fixation injected with PRP; twelve patients in group B were managed only by closed reduction a

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Thu Feb 28 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The Impact of Adequacy and Authoritative Evidences in the Audit Risks: An Exploratory Research for A Sample Views of Auditors in Iraq
...Show More Authors

The Audit evedances represent the reconciliation tools between the Financial data shown on financial statements, and the level of satisfaction level of the Auditor about these statements. According that, the Auditor try to achieve the highest quantity of These evidances, and the most satisfactive of it…, but that will be so hard sometimes, when the internal controlling system is not good, and when the Auditor had some satisfied evidences, but not sharp… So, this research comes to inspect the relation between the quantity, and the level of satisfaction, and argument to prove that evidences gives. This research assumes that getting enough evidences leads to reduce faults, improves the auditing operation, and avoids risks. The research

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Production of protease, an analyst for the blood clot from a variety of fungal isolates / 1 rating fungal isolates and agricultural circles
...Show More Authors

House 21 fungal isolates fungus to the analyst Albroca output of manufactured blood clot from the Blama human blood showed positive fungi to test analyzes blood clot variation in times where decomposition recorded fungi

View Publication Preview PDF
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Gamma Irradiation Effects on Energy Transfer Parameters for Acrvlaven – Rhodamine19 Binary Laser Dye Mixtures
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Gamma Irradiation Effects on Energy Transfer Parameters for Acrvlaven – Rhodamine19 Binary Laser Dye Mixtures
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Fri Sep 29 2023
Journal Name
Pakistan Journal Of Ophthalmology
Corneal Parameters Measurement in Healthy Subjects Using Scheimpflug and Anterior Segment Optical Coherence Tomography
...Show More Authors

Purpose:  To compare the central corneal thickness (CCT),minimum corneal thickness (MCT) and corneal power measured using theScheimpflug-Placido device and optical coherence tomography (OCT) in healthy eyes. Study Design:  Descriptive observational. Place and Duration of Study:  Al-Kindy college of medicine/university of Baghdad, from June 2021 to April 2022. Methods:  A total of 200 eyes of 200 individuals were enrolled in this study. CCT and MCT measurements were carried out using spectral-domain optical coherence tomography (Optovue) and a Scheimpflug-Placido topographer (Sirius).The agreement between the two approaches was assessed using Bland-Altman analysis in this study. Results:  Mean age was 28.54 ± 6.6 years, me

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
Low dose tadalafil effect on anthropometric and metabolic parameters in Iraqi diabetic obese men
...Show More Authors

Background: Phosphodiesterase-5 (PDE-5) inhibitorsrestore nitric oxide (NO) signaling and may reducecirculating inflammatory markers, and improve metabolicparameters through a number of mechanisms. Dailyadministration of the PDE-5 inhibitor, tadalafil (TAD) mayattenuate inflammation; improve fasting plasma glucose andtriglyceride levels and body weight. This study aims toevaluate the efficacy of low dose PDE-5 inhibitor, tadalafil(TAD) in controlling dysglycemia and body weight in obesediabetic men.Methods: Forty obese men with type 2 diabetes aged 30-50years incorporated in this study, all with A1c of 7-8.5%,attending obesity unit in AL-Kindy college of medicine.Weight, height, BMI, FPG, A1c, cholesterol, TG, HDL andLDL measured for all

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
Inelastic magnetic electron scattering M1 form factors in Ca-48 (M3Y fitting parameters consideration)
...Show More Authors

Inelastic magnetic electron scattering M1 at Ex =10.23 MeV form factors in Ca-48 have been investigated. The fp shell model space with four orbits and eight neutrons have been considered and FPD6 has been selected between 32 model space effective interactions to generates the model space vectors for the M1 transition with excitation energy Ex =10.23 MeV and for constructing OBDM. Discarded space (core and higher configuration orbits) has been included through the first order perturbation theory to couple the partice-hole pair of excitation in the calculation of the total M1 form factor and regarding the realistic interaction M3Y as a core polarization interaction with six sets of fitting parameters. Finally the theoretical calculations h

... Show More
View Publication Preview PDF