Preferred Language
Articles
/
mRfEXJIBVTCNdQwCQ61g
A N-Radon Based OFDM Trasceivers Design and Performance Simulation Over Different Channel Models
...Show More Authors

In this paper a new method is proposed to perform the N-Radon orthogonal frequency division multiplexing (OFDM), which are equivalent to 4-quadrature amplitude modulation (QAM), 16-QAM, 64-QAM, 256-QAM, ... etc. in spectral efficiency. This non conventional method is proposed in order to reduce the constellation energy and increase spectral efficiency. The proposed method gives a significant improvement in Bit Error Rate performance, and keeps bandwidth efficiency and spectrum shape as good as conventional Fast Fourier Transform based OFDM. The new structure was tested and compared with conventional OFDM for Additive White Gaussian Noise, flat, and multi-path selective fading channels. Simulation tests were generated for different channels parameters values including multi-path gains vector, multi-path delay time vector, and maximum Doppler shift. © 2009 Springer Science+Business Media, LLC.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri May 01 2020
Journal Name
International Journal Of Psychosocial Rehabilitation
Building and codifying a scale of the level of tactical performance of advanced volleyball players
...Show More Authors

The research objectives, to build a measure of the level of tactical performance of volleyball players applying for the Iraqi Premier League for the 2018-2019 season. The nature of the research problem, then the researchers determined the research sample in the deliberate manner of the players of the Iraqi clubs for the Premier League (B, A). The researchers adopted the entire community as a sample for the research, and the number (156) players distributed over (13) clubs and divided the sample into (12)players an exploratory experiment player representing (the police club) and (100) player representing the construction sample and after a maximum period of two months has passed since applying the scale to the construction sample the researc

... Show More
Preview PDF
Publication Date
Wed Jan 04 2023
Journal Name
Frontiers In Chemestry
Thermal and flow performance analysis of a concentrated linear Fresnel solar collector with transverse ribs
...Show More Authors

This article deals with the impact of including transverse ribs within the absorber tube of the concentrated linear Fresnel collector (CLFRC) system with a secondary compound parabolic collector (CPC) on thermal and flow performance coefficients. The enhancement rates of heat transfer due to varying governing parameters were compared and analyzed parametrically at Reynolds numbers in the range 5,000–13,000, employing water as the heat transfer fluid. Simulations were performed to solve the governing equations using the finite volume method (FVM) under various boundary conditions. For all Reynolds numbers, the average Nusselt number in the circular tube in the CLFRC system with ribs was found to be larger than that of the plain abs

... Show More
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40
...Show More Authors

This study examines experimentally the performance of a horizontal triple concentric tube heat exchanger TCTHE made of copper metal using water as cooling fluid and oil-40 as hot fluid. Hot fluid enters the inner annular tube of the TCTHE in a direction at a temperature of 50, 60 and 70 oC and a flow rate of 20 l/hr. On the other hand, the cooling fluid enters the inner tube and the outer annular tube in the reverse direction (counter current flow) at a temperature of 25 oC and flow rates of 10, 15, 20, 25, 30 and 35 l/hr. The TCTHE is composed of three copper tubes with outer diameters of 34.925 mm, 22.25 mm, and 9.525 mm, and thicknesses of 1.27 mm, 1.143 mm, and 0.762 mm, respectively. TCTHE tube's length was 670

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
International Journal Of Low-carbon Technologies
Performance evaluation of the photovoltaic thermal system with a fin array and surface zigzag layout
...Show More Authors
Abstract<p>Solar photovoltaic (PV) has many environmental benefits and it is considered to be a practical alternative to traditional energy generation. The electrical conversion efficiency of such systems is inherently limited due to the relatively high thermal resistance of the PV components. An approach for intensifying electrical and thermal production of air-type photovoltaic thermal (PVT) systems via applying a combination of fins and surface zigzags was proposed in this paper. This research study aims to apply three performance enhancers: case B, including internal fins; case C, back surface zigzags; and case D, combinations of fins and surface zigzags; whereas the baseline smooth duct rep</p> ... Show More
View Publication
Scopus (13)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Thu Sep 30 2021
Journal Name
Journal Of Economics And Administrative Sciences
HRA and its Impact on Employees Performance: A Field Research in the Ministry of Education
...Show More Authors

          The research aims to determine the impact of Human Resources Accounting (HRA) on employee’s performance. The research’s problem was embodied in the lack of interest in HRA, which was reflected on the performance of employees in the Ministry of Education; the research adopted the descriptive-analytical approach, and the research community included the directors of departments and people at the headquarters of the Ministry of Education. The sample size was (224) individuals from the total community of 533. The questionnaire was adopted as the main tool for collecting data and information, as well as the interviews that were conducted by the researcher. In order to analyze t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
EXHAUST ANALYSIS AND PERFORMANCE OF A SINGLE CYLINDER DIESEL ENGINE RUN ON DUAL FUELS MODE
...Show More Authors

Generally fossil based fuels are used in internal combustion engines as an energy source.
Excessive use of fossil based fuels diminishes present reserves and increases the air pollution in
urban areas. This enhances the importance of the effective use of present reserves and/or to develop
new alternative fuels, which are environment friendly. Use of alternative fuel is a way of emission
control. The term “Alternative Gaseous Fuels” relates to a wide range of fuels that are in the
gaseous state at ambient conditions, whether when used on their own or as components of mixtures
with other fuels.
In this study, a single cylinder diesel engine was modified to use LPG in dual fuel mode to study
the performance, emis

... Show More
View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Thu Feb 28 2019
Journal Name
Journal Of Engineering
Hydraulic Analysis and Performance Evaluation of Combined Trunk Sewers: A Case Study of Baghdad City.
...Show More Authors

Sewer system plays an indispensable task in urban cities by protecting public health and the environment. The operation, maintenance, and rehabilitation of this network have to be in a sustainable and scientific manner. For this purpose, it is important to support operators, decision makers and municipalities with performance evaluation procedure that is based on operational factors. In this paper, serviceability and performance indicator (PI) principles are employed to propose methodology comprising two enhanced PI curves that can be used to evaluate the individual sewers depending on operational factors such as flowing velocity and wastewater level in the sewers. In order to test this methodology; a case study of al-Ru

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Engineering
Performance of Solar Adsorption Cooling System Using Methanol and Activated Carbon as a Working Pair
...Show More Authors

The need for renewable energy sources is higher than ever due to rising global warming, climate change, and ozone depletion. For refrigeration and air conditioning applications, adsorption refrigeration systems are viable alternatives cooling techniques. This study is a topic and part of the M.Sc. thesis. A field solar-powered ice maker unit was created, studied, tested, and evaluated on the 13th and 30th of May, 2022. Activated carbon and methanol pair was used to set up a refrigeration system in Baghdad (Al Dora). Experimental tests were carried out outdoors to determine the coefficient of performance COP and specific cooling power SCP of the system. The results showed that the lowest temperature

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Engineering
Hydraulic Analysis and Performance Evaluation of Combined Trunk Sewers: a Case Study of Baghdad City.
...Show More Authors

Sewer system plays an essential task in urban cities by protecting public health and the environment. The operation, maintenance, and rehabilitation of this network have to be sustainable and scientifically. For this purpose, it is crucial to support operators, decision makers and municipalities with performance evaluation procedure that is based on operational factors. In this paper, serviceability and performance indicator (PI) principles are employed to propose methodology comprising two enhanced PI curves that can be used to evaluate the individual sewers depending on operational factors such as flowing velocity and wastewater level in the sewers. To test this methodology; a case study of al-Rusafa in Baghdad city is

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Oct 16 2021
Journal Name
Energies
Performance Analysis of a Solar Cooling System with Equal and Unequal Adsorption/Desorption Operating Time
...Show More Authors

In solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational

... Show More
View Publication
Scopus (11)
Crossref (12)
Scopus Clarivate Crossref