Preferred Language
Articles
/
mRebao0BVTCNdQwCOxTH
Strength and Deformation of Concrete-Encased Grouting-Filled Steel Tubes Columns Exposed to Monotonic Quasi-Static Loading Conditions
...Show More Authors

This study aimed to evaluate the effectiveness of a novel concrete-encased column (CE) using small circular steel tubes filled with cementitious grouting material (GFST) as the primary reinforcement instead of traditional steel bars. The research involved three different types of reinforcement: conventional steel bars, concrete-filled steel tubes with 30% of the reinforcement ratio of steel bars, and concrete-filled steel tubes with the same reinforcement ratio as steel bars. Twenty-four circular concrete columns were tested and categorized into six groups based on the type of reinforcement employed. Each group comprised four columns, with one subjected to concentric axial load, two subjected to eccentric axial load (with eccentricities of 25 mm and 50 mm, respectively), and one tested under lateral flexural loads. To validate the experimental results, finite element (FE) analysis was conducted using ABAQUS software version 6.14. The experimental findings for concentric load reveal that columns with the second type of reinforcement, concrete-filled steel tubes with 30% of the reinforcement ratio of steel bars exhibited a failure load 19% lower than those with steel bars, while columns with the third type of reinforcement, concrete-filled steel tubes with the same reinforcement ratio as steel bars achieved a failure load 17% greater than the traditional steel bars. The FE analysis demonstrates good agreement with the experimental outcomes in terms of ultimate strength, deformation, and failure modes.

Scopus Clarivate Crossref
View Publication
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
An Efficient Shrinkage Estimators For Generalized Inverse Rayleigh Distribution Based On Bounded And Series Stress-Strength Models
...Show More Authors
Abstract<p>In this paper, we investigate two stress-strength models (Bounded and Series) in systems reliability based on Generalized Inverse Rayleigh distribution. To obtain some estimates of shrinkage estimators, Bayesian methods under informative and non-informative assumptions are used. For comparison of the presented methods, Monte Carlo simulations based on the Mean squared Error criteria are applied.</p>
View Publication
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Fri Oct 01 2021
Journal Name
Journal Of Engineering
Critical Evaluation for Grading and Fineness Modulus of Concrete Sands used in Sulaymaniyah City-Iraq
...Show More Authors

Fine aggregates used for concrete works in Sulaymaniyah city frequently fail to meet the standard requirements for gradation and fineness modulus in cement concrete. This paper aims to critically evaluate gradation, fineness modulus, and clay contents of various natural sands produced and used for concrete work in the region.  Sixteen field sand samples were collected from various sites in Darbandikhan (5 samples), Qalat Dizah (5 samples), Koysinjaq (5 samples), and Piramagroon (1 sample) confirming to ASTM D75. The field samples were parted into test specimens based on ASTM C702. Then, sieve analysis was carried out on the oven-dry test specimens in compliance with ASTM C136. The test results of fine aggregates wer

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Fri Oct 01 2021
Journal Name
International Journal Of Geomate
NONLINEAR SIMULATION ANALYSIS OF TAPERED REINFORCED CONCRETE COLUMN (SOLID AND HOLLOW) BEHAVIOR UNDER AXIAL LOAD
...Show More Authors

View Publication
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Aug 01 2019
Journal Name
The Journal Of Solid Waste Technology And Management
Recycling of Waste Compact Discs in Concrete Mix: Lab Investigations and Artificial Neural Networks Modeling
...Show More Authors

This study aimed to investigate the incorporation of recycled waste compact discs (WCDs) powder in concrete mixes to replace the fine aggregate by 5%, 10%, 15% and 20%. Compared to the reference concrete mix, results revealed that using WCDs powder in concrete mixes improved the workability and the dry density. The results demonstrated that the compressive, flexural, and split tensile strengths values for the WCDs-modified concrete mixes showed tendency to increase above the reference mix. However, at 28 days curing age, the strengths values for WCDs-modified concrete mixes were comparable to those for the reference mix. The leaching test revealed that none of the WCDs constituents was detected in the leachant after 180 days. The

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Journal Of Engineering
Experimental Investigation of Crack Initiation and Growth in Concrete Slabs Placed Directly on Clayey Soil
...Show More Authors

The main objective of this study is to examine the impact of moisture concrete of clayey soil on the concrete slabs placed directly over it. This experimental study presents the mechanical properties of the concrete slab when placed on different clayey soil moisture content ranging from 0% to the optimum moisture content of 35%. The tests were performed on soil concrete specimens of 25*30*50 mm exposed to sprayed water curing conditions for 28 days. Tests of compressive strength, ultrasonic pulse velocity, crack depth and crack width were investigated through this paper. An ejection relationship between compressive strength of concrete and water content in the soil was observed, with a 26% increase with water increasing from 0% to 35%. T

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 17 2016
Journal Name
Al-academy
Conditions The chromatography in the design the positions waiting passenger transport buses: مصعب حسن عبد
...Show More Authors

running the requirement color important place in object of life activity both public and private, Fallon makes represents energy expressive and aesthetic in designing furniture street, especially (positions waiting buses passenger transport)which took looms large in attention receiver designer also, through civilized development and urban and change the city. Requirement, The positions of waiting progress jobs service and that would interact to produces Photos aesthetic Furniture for space street and understand receiver, affect the operation his life and the development of his environment and his psyche and culture of because they entity variable and sophisticated, impose on us to find foundations a design and conditions of chromatic esp

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 19 2014
Journal Name
Romanian Biotechnological Letters
Optimization conditions for bioemulsifier production by local Streptomyces sp. SS20 isolated from hydrocarbon contaminated soil
...Show More Authors

Publication Date
Thu Oct 21 2021
Journal Name
Physical Review E
Lattice Boltzmann method with moment-based boundary conditions for rarefied flow in the slip regime
...Show More Authors

View Publication
Scopus (9)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Mechanical Engineering Research And Developments
Fatigue life of welded joint improvement with various welding principles and shot peening process for AISI 1020 low carbon steel
...Show More Authors

Preview PDF
Scopus (1)
Scopus
Publication Date
Wed Sep 22 2021
Journal Name
International Journal Of Corrosion And Scale Inhibition
Synthesis of a CoO–ZnO nanocomposite and its study as a corrosion protection coating for stainless steel in saline solution
...Show More Authors

Reaxys Chemistry database information SciVal Topics Metrics Abstract A novel CoO–ZnO nanocomposite was synthesized by the photo irradiation method using a solution of cobalt and zinc complexes and used as a coating applied by electrophoretic deposition (EPD) for corrosion protection of stainless steel (SS) in saline solution. The samples were characterized using powder XRD, scanning electron microscopy (SEM) and electrochemical polarization. It was also found that the coating was still stable after conducting the corrosion test: it contained no cracks and CoO–ZnO nanocomposites clearly appeared on the surface. SEM showed that the significant surface cracking disappeared. XRD confirmed that CoO–ZnO nanocomposites comprised CoO and Zn

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (4)
Scopus Clarivate Crossref