Preferred Language
Articles
/
mReajJMBVTCNdQwCXtWh
Plasma Optical Emission Spectroscopy Study of Some Iron Meteorites
...Show More Authors

This study aims to analyze spectra in real-time for λ Draconids, σ Hydrids, μ Virginid, and one sporadic meteor using spectroscopic chemical analysis and diagnose plasma parameters. Good-resolution spectroscopy and a CCD camera for meteor observation were used concurrently to examine the ablation spectra of these meteorites in situ. The Boltzmann and Lorentz methods were then used to determine the temperature and density of electrons, the length of Debye, and the frequency of plasma. Furthermore, spectra data can be analyzed and compared to data from other sources. Spectrum tests can be utilized to identify the chemical structure of meteorites' plasma.

Scopus Crossref
Preview PDF
Quick Preview PDF
Publication Date
Sat Mar 01 2025
Journal Name
Al-iraqia Journal For Scientific Engineering Research
Blue Laser Optical NOMA Communication Applied on Control Drone-to-Underwater Vehicle
...Show More Authors

oday deep ocean life has not been discovered by humans including many secret world things to be explored. The researcher has focused on underwater optical wireless communications using various kinds of complex digital Signal processing most of them used in air and starting applied in underwater communication. The Internet of Things (IoT) uses underwater called Internet of Underwater Things (IoUT) applications to explore the underwater world with other devices. However, the difference in concentration between air and water surfaces is not easy making wireless communication more complicated. Visible light passes the water's surface with scattering and distortion inside the water and each color of light has different attenuation the blue laser

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 01 2018
Journal Name
Iraqi Journal Of Science
Polymer optical fiber sensor side-pumped with polymer clad doped lasing compounds
...Show More Authors

Preview PDF
Scopus (4)
Scopus Crossref
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Design and Implementation for optical fiber communication system using frequency shift coding
...Show More Authors

In this research, optical communication coding systems are designed and constructed by utilizing Frequency Shift Code (FSC) technique. Calculations of the system quality represented by signal to noise ratio (S/N), Bit Error Rate (BER),and Power budget are done. In FSC system, the data of Nonreturn- to–zero (NRZ ) with bit rate at 190 kb/s was entered into FSC encoder circuit in transmitter unit. This data modulates the laser source HFCT-5205 with wavelength at 1310 nm by Intensity Modulation (IM) method, then this data is transferred through Single Mode (SM) optical fiber. The recovery of the NRZ is achieved using decoder circuit in receiver unit. The calculations of BER and S/N for FSC system a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Radioelectronics And Communications Systems
Optical CDMA Coded STBC Based on Chaotic Technique in FSO Communication Systems
...Show More Authors

Free-Space Optical (FSO) can provide high-speed communications when the effect of turbulence is not serious. However, Space-Time-Block-Code (STBC) is a good candidate to mitigate this seriousness. This paper proposes a hybrid of an Optical Code Division Multiple Access (OCDMA) and STBC in FSO communication for last mile solutions, where access to remote areas is complicated. The main weakness effecting a FSO link is the atmospheric turbulence. The feasibility of employing STBC in OCDMA is to mitigate these effects. The current work evaluates the Bit-Error-Rate (BER) performance of OCDMA operating under the scintillation effect, where this effect can be described by the gamma-gamma model. The most obvious finding to emerge from the analysis

... Show More
View Publication
Scopus (6)
Crossref (6)
Scopus Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Tunable Optical filters Using Etched Polarization Maintaining Fiber Hybrid Sagnac Interferometer
...Show More Authors

: In modern optical communication system, noise rejection multiple access interference (MAI) must be rejected in dense access network (DAN). This paper will study the dual optical band pass and notch filters. They will be extracted with tunable FWHM using 10cm (PMF) with different cladding diameters formed with etching 125μm PMF after immersing it with 40% of hydrofluoric acid (HF). This fiber acts as assessing fiber to perform Sagnac interferometer with splicing regions that placed 12cm (SMF) for performing hybrid Sagnac interferometer that consists of Mach-Zehnder instead of Sagnac loop which is illuminated by using laser source with centroid wavelength of 1546.7nm and FWHM of 286 pm or 9 ns in the time domain. . Firs

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 10 2025
Journal Name
Chemchemtech
LC-MS/MS METHOD FOR THE DETERMINATION OF IMATINIB MESYLATE IN BLOOD PLASMA SAMPLES AFTER ADSORPTION BY COPPER TANNIC ACID
...Show More Authors

A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.

... Show More
View Publication
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Fri Jan 10 2025
Journal Name
Chemchemtech
LC-MS/MS METHOD FOR THE DETERMINATION OF IMATINIB MESYLATE IN BLOOD PLASMA SAMPLES AFTER ADSORPTION BY COPPER TANNIC ACID
...Show More Authors

A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.

... Show More
View Publication
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Journal Of Physics: Conference Series
Analytical Study of the Royal-Jelly Effect on Sperms Morphological Characteristics and some Liver Function Parameters and their Correlation with some Antioxidants in Male Albino Rats Treated with Pregabalin Drug
...Show More Authors
Abstract<p>In recent years, the consideration of natural products as anti-inflammatory and antioxidative treatments has more interested worldwide. Moreover, natural products are easily obtained and are relatively safe the Royal jelly (RJ) is one of them. The current study was carried to evaluate the effects of pregabalin (PGB) on physiological activity of sperms, reproductive hormones assay and some biochemical analysis. Forty (40) male albino rats (10-weeks-old) were divided into four groups (10 rats each): G1 (treated with PGB drug, 150 mg/kg B.wt (Lyrica-Pfizer-Pharmaceutical Industries), G2 (treated with RJ 1g/kg), G3 (treated with PGB drug and RJ together), and G4 control treated with norma</p> ... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Feb 28 2019
Journal Name
The Open Rheumatology Journal
The Value of Soluble Transferrin Receptor and Soluble Transferrin Receptor-ferritin Index in Discriminating Iron Deficiency Anaemia from Anaemia of Chronic Disease in Patients With Rheumatoid Arthritis
...Show More Authors
Background:

Anaemia is a common extra-articular manifestation of rheumatoid arthritis (RA) where anaemia of chronic disease (ACD) and iron deficiency anaemia (IDA) are the two most frequent types. The distinction between these two types of anaemia has always been challenging requiring sophisticated techniques. Serum transferrin receptor (sTfR) a truncated soluble form of the transferrin receptor is one of the parameters that is influenced by the Iron content and supply to the erythrons and is not affected by inflammatory status and therefore the use of the sTfR/log ferritin (sTfR-F) index can be a reliable indicator of functional iron deficiency.

Aim of the s
... Show More
View Publication Preview PDF
Scopus (6)
Crossref (4)
Scopus Crossref
Publication Date
Sun Mar 05 2017
Journal Name
Baghdad Science Journal
Positive and Negative Aspects of Copaxone ( Glatiramer acetate) Action on TC, TG HbA1c and Iron Levels in The Sera of Iraqi Women with Multiple Sclerosis in Baghdad
...Show More Authors

The aim of the present study is to highlight the role of total cholesterol (TC), triacylglycerol (TG), Glycated hemoglobin A1c and iron in Iraqi women with multiple sclerosis and also to examine the biochemical action of copaxone (which is the most widely used in the 21st century to treat multiple sclerosis) on these biochemical parameters. This is the first study in Iraq which deals copaxone action on TC , TG , HbA1c and iron. Ninety women in their fourth decade suffering from multiple sclerosis were enrolled in this study. They were divided into: the first (group B) composed of (30) women without any treatment related to multiple sclerosis or any treatment linked with chronic or inflammatory diseases. The second (group A1) included (30)

... Show More
View Publication Preview PDF
Scopus Crossref