Preferred Language
Articles
/
mRdsX5MBVTCNdQwCe9IB
Role of Gamma Camera Components in Radiological Diagnosis
...Show More Authors

The gamma camera, along with SPECT and PET scanners, is one of the main imaging technologies in nuclear medicine. A collimator is typically constructed from tungsten to provide high absorption of gamma photon energies. It has a hole or holes for imaging. Gamma rays from a radioactive source within the body are emitted in all directions, while the photons required constructing an image travel through the hole. A scintillator is the most common material used to convert the high energy of gamma radiation into a lowenergy optical photon. These detectors are one of the primary secrets to radio-diagnosis in nuclear medicine. The photomultiplier tube (PMT) is a versatile device with extraordinarily highly sensitivity and response. A typical photomultiplier tube contains a photo emissive cathode (photocathode), focusing electrodes, an electron multiplier, and an electron collector (anode). Conclusion: In the medical imaging area, everyone works to improve the resolution, sensitivity, and size of their devices so that patients can be treated better and diagnoses can be made more accurately. Also, the results of this study suggest that HGC could be a potential way to give better support during surgery.

Publication Date
Thu Mar 09 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect Gamma Radiation of CdTe Thin Films Deposited by Thermal Evaporation
...Show More Authors

       The effect of 0.66 µeV gamma radiation on the structural and optical properties of the CdTe thin films prepared by thermal evaporation at thickness 350nm, The samples were irradiated with time (50 h and 79h) at room temperature. The absorption spectra for all the samples were recorded using UV-VIS spectrometer in order to calculate the energy gap, refractive index and others parameter . The optical energy gap was found decrease from (1.9 to 1.67) eV. 

View Publication Preview PDF
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Gamma Ray Effect on the Properties of Coumarin C47 Laser Dye
...Show More Authors

The research is concerned about studying the absorption spectrum of the solution coumarin dye C47. The chloroform solvent was used with C47 dye in three different concentrations 10-4, 10-5 and 10-6 M. The laser dye solution was prepared by dissolving the required amount of dye in chloroform alcohol, while studying absorption spectrum before and after irradiation with gamma ray by cobalt-60 source 60Co at exposure time, which are 0, 4, 6 and 18 hours with different absorbed doses 0, 136, 204 and 612 Gy. The results show that red shift in the absorption spectrum was increased by increasing the concentration of laser dye solutions , while the increase of gamma dose led to increase the red shift after irradiation, as the exposure period and irr

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Thu Feb 01 2024
Journal Name
Baghdad Science Journal
Comparative Study of Gamma- Ray Shielding Parameters for Different Epoxy Composites
...Show More Authors

In the current work various types of epoxy composites were added to concrete to enhance its effectiveness as a gamma- ray shield. Four epoxy samples of (E/clay/B4C) S1, (E/Mag/B4C) S2, (EPIL) S3 and (Ep) S4 were used in a comparative study of gamma radiation attenuation properties of these shields that calculating using Mont Carlo code (MCNP-5). Adopting Win X-com software and Artificial Neural Network (ANN), µ/ρ revealed great compliance with MCNP-5. By applying (µ/ρ) output for gamma at different energies, HVL, TVL and MFP have been also estimated. ANN technique was simulated to estimate (µ/ρ) and dose rates. According to the results, µ/ρ of all epoxy samples scored higher than standard concrete. Both S2 and S3 samples having h

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Value of Ultrasonography in The Diagnosis and Evaluation of Early Therapeutic Response of Cervical Tuberculous Lymphadenitis
...Show More Authors

ABSTRACT Background: Tuberculosis is a worldwide infectious disease in spite of advancement in health care system. Tuberculous lymphadenitis is the most prevalent form of extra pulmonary tuberculosis with predilection of cervical lymph nodes. Objectives: To evaluate the reliability of grey scale ultrasonography together with color Doppler in the diagnosis of cervical tuberculous lymph adenitis and evaluation of early therapeutic response. Subjects and methods:From July 2015 to May 2016 in Al-Karama teaching hospital /Kut city- Wasit-Iraq, 25 patients (14 males and 11 females) with ages range from (6-50) years. Ultrasonography examination was done for all patients and grey scale criteria (distribution, size, shape, echogenicity, echogenic hi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Measurement of indoor radon levels and assessment of radiological hazards at Al-Tuwaitha nuclear site and the surrounding area
...Show More Authors

In the present study the radon concentration was measured in indoor places by the RAD7 (radon detector) was in some locations at Al-Tuwaitha nuclear site and some surrounding areas for the duration from 13/10/2016 to 2/1/2017 and the measurement of the indoor radon concentration ranged from (4.96±4.4 to 102±25) Bq/m3. The high value of radon has been found at decommissioning directorate /emergency room, which is lower than the action value recommended by the Environmental Protection Agency (EPA) which is (148 Bq/m3) while the lowest value has been founded in central laboratories directorate \ models room. These values were used to calculate the annual effective dose and the health risks for cells bronchial which caused by the inhalatio

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 01 2024
Journal Name
The Medical Journal Of Tikrit University
ChemiluminescenceMicroparticle Immunoassay in the Diagnosis of Hepatitis C Virus among Patients on Hemodialysis: A Comparative Study
...Show More Authors

Browse Iraqi academic journals and research papers

View Publication
Publication Date
Sun Jan 01 2023
Journal Name
Technologies And Materials For Renewable Energy, Environment, And Sustainability: Tmrees23fr
The effect between combination of cold plasma and gold nano material on blood components
...Show More Authors

A simple low-cost approach at various exposure times was utilized to generate cold plasma in the aim to fabricate AuNPs. UV-Visible spectra and X-ray diffraction were used to characterize the nanoparticles (XRD). Surface Plasmon resonance was observed in the synthesized AuNPs at 530, 540, and 533 nm. For all samples, the patterns of XRD show very intensive peaks implying the fcc crystalline structure of AuNPs. The average crystallite size of AuNPs is ranging between 20-30 nm. The observation of morphology by FESEM revealed the spherical formation of AuNPs. Doses of 100 and 200 ppm of AuNPs were adapted to investigate their effect on the blood-mixture with and without a 20-second of cold plasma exposure. The WBC components in the blood

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Sep 23 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Evaluation of a Dot -ELIZA for the Diagnosis of Human Hydatid Disease
...Show More Authors

Fourty  -tow   Libyan     patients  with  hydatidosis,  which  were

referred to by the physician for the detection of hydatid cyst by X - rays, Ultrasound and CT-Scan.  The  infection rate  in  females and males was(69% )and (31% )respectively .The highest rate 69% was in the liver, followed by the lung( 23.8%), the brain (4.8%) and kidney

(2.4%).

A total of  42 serum  samples were gathered from Libyan patients infected with hydatidosis, 33 serum samples from patients cases with other parasitic diseases than hydatidosis and 30 serum samples from healthy normal controls and were tested by Dot-ELIZA utilizing antigen B from sheep hy

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Dependence of gamma-ray absorption coefficient on the size of lead particle
...Show More Authors

In this study, dependence of gamma-ray absorption coefficient on the size of Pb particle size ranging from 200µm up to 2.5mm, using different weights of each particle size. The results show that gamma-ray attenuation coefficient is inversely proportional with the size of Pb particle size due to the reduction of the spaces between the lead particles.

View Publication Preview PDF
Crossref
Publication Date
Thu Jun 30 2016
Journal Name
Al-kindy College Medical Journal
Power Versus Conventional Color Doppler Sonographic Diagnosis Of Acute Cholecystitis: Comparison In The Depiction Of Mural Flow
...Show More Authors

Background: Gray-scale sonography is generally
considered as a first-line diagnostic tool for patient with
suspected acute cholecystitis. It is suggested by gallstones,
Murphy's sign, thickening of the gallbladder wall and bile
sludging, but the specificity of these sonographic findings
are not as high as their sensitivity. Blood flow of the
gallbladder wall is increased in acute inflammation.
Objective: To evaluate the sensitivity and specificity of
power Doppler sonography and compared with conventional
color Doppler and gray-scale sonography in diagnosing
patients with acute cholecystitis.
Type of the study: This was a cross sectional study.
Patients and methods: The study was conducted t

... Show More
View Publication Preview PDF