Background: Fractures of the humeral shaft accounting for approximately 3% of all fractures. There is a wide array of good options for their treatment and controversy over the best methods. Although good techniques of osteosynthesis are available, the aim of this article is toemphasize on the benefit and good outcome of conservative treatment for properly selected cases to decrease the cost and avoid the complications of surgery. Method : During the period from February 2011 to June 2012 fifty-five fractures of humeral shaft were treated at orthopedicdepartment in the ALKindyteaching hospital. 22 fractures considered suitable for the study. The patients treatedconservatively by using the‘U’ shaped coaptation slab. Then we shift to POP cast or functional brace after one week.Then we follow the patient clinically and radiologically every 2weeks until the fracturehad united and the limb functions were restored. The outcome of treatment was assessed by specificparameters which include alignment, rate of union and limb functions. outcome: This study showed thatthe initial deformities of angulations were considerably reduced by the use of U slab and the POP castwhich act as a dynamic rather than a static splint,or functional brace through soft-tissue compression correcting angulation to less than 30° in coronalplane and less than 20° in sagital plane. Manipulation of the fracture was not required and didnot affectneither the rate of union nor the final position, as the cast appeared to be capable of correctingangulation deformities. Perfect anatomical reduction was found not to be essential for satisfactory limbfunction, which was present with varus angulation and posterior bowing. The incidence of delayedunion compares favorably with other reported series, although the definition of delayed union isvariable. Conclusion: In fracture shaft of humerus, neither rigid immobilization nor perfect alignment are of great importance for final outcome, so conservative treatment is one of the most effectivemethods of treatment and the operative treatment can lead to adverse effect on the outcome in case ofbad judgment and should be limited as much as possible to specific indications
BACKGROUND: Transverse fractures of the patella are important fractures with a wide variety of subtypes, the common incidence in the age group of 20–50 years. Surgical interference aims to achieve a perfect alignment of the joint surface, in addition to rigid fixation of the fracture for early re-habitation and early movement to retain the extensor mechanism of the knee joint. AIM: The aim of this study was to compare the radiological and functional outcomes of the displaced transverse patella fracture in adult patients treated by ORIF using tension band wiring versus cannulated screws with wiring. METHODS: A prospective analytic comparative study was conducted in Al-Kindy Teaching Hospital/Baghdad/Iraq for 18 months from Apr
... Show MoreThe electrode in the microbial fuel cell has a significant effect on cell performance. The treatment of the electrode is a crucial step to make the electrode surface more habitable for bacteria growth, thus, increases the power production as well as waste treatment. In the current study, two graphite electrodes were treated by a microwave. The first electrode was treated with 100W microwave energy, while the second one was treated with 600W microwave energy. There is a significant enhancement in the surface of the graphite anode after the pretreatment process. The results show an increase in the power density from 10 mW/m2 to 15 mW/m2 with 100w treatment and to 13.47 mW/m2 with 600w treatment. An organic
... Show More
Background: Oral anticoagulation medication, warfarin and non-vitamin k antagonist oral anticoagulants (NOAC) may require long term use which may affect patients’ satisfaction with their treatment and their quality of life (QOL). Objective: To compare the quality of life and treatment satisfaction among groups of patients using different anticoagulant therapies (warfarin and NOAC). Patients and methods: A cross-sectional study was performed at Ibn Al-Bitar Hospital for cardiac surgery in Baghdad in the period between December 2022 to May 2023. The study population included a convenient sample of patients receiving either warfarin or non-vitamin k antagonist oral anticoagulants treatment. The Arabic version of the short form 12
... Show MoreThe issue of the prisoners' rights and the way of dealing with them is not just a minor or
primary issue according to the contemporary attitudes to deal with criminals, but it is a fatal
issue that goes with the development of life and comprehension of human rights. As the
criminal is considered as a human-being who can be reformed and qualified, according to the
aims of the contemporary social service the prisoner is regarded as an idle human source who
can be reformed, treated and qualified so as to make him participate to improve his family and
society in the end.
This study aims at reconstructing the prisons bases when applying the laws of the lowest
level of treatment through the research of oppositions, atti
Background: The treatment of articular cartilage defects is one of the most clinical challeng for orthopedic surgeons. Articular cartilage is a highly organized tissue with complex biomechanical properties and substantial durability. However, it has a poor ability for healing, and damage from trauma or degeneration can result in morbidity and functional impairment. debilitating joint pain, dysfunction, and degenerative arthritis &nbs
... Show MoreThis research deals with the design and simulation of a solar power system consisting of a KC200GT solar panel, a closed loop boost converter and a three phase inverter by using Matlab / Simulink. The mathematical equations of the solar panel design are presented. The electrical characteristics of the panel are tested at the values of 1000 for light radiation and 25 °C for temperature environment. The Proportional Integral (PI) controller is connected as feedback with the Boost converter to obtain a stable output voltage by reducing the oscillations in the voltage to charge a battery connected to the output of the converter. Two methods (Particle Swarm Optimization (PSO) and Zeigler- Nichols) are used for tuning
... Show MoreA field-pilot scale slow sand filter (SSF) was constructed at Al-Rustamiya Sewage Treatment Plant (STP) in Baghdad city to investigate the removal efficiency in terms of Biochemical Oxygen Demand (BOD5), Chemical oxygen demand (COD), Total Suspended Solids (TSS) and Chloride concentrations for achieving better secondary effluent quality from this treatment plant. The SSF was designed at a 0.2 m/h filtration rate with filter area 1 m2 and total filter depth of 2.3 m. A filter sand media 0.35 mm in size and 1 m depth was supported by 0.2 m layer of gravel of size 5 mm. The secondary effluent from Al-Rustamiya STP was used as the influent to the slow sand filter. The results showed that the removal of BOD5, COD, TSS, and Chloride were
... Show MoreWere not experience Khalil Hawi capillary module as presented or routine in the format
of the implications , but was saturated transitions quality that targeted built by visionary and
mechanisms expressive , Valgosaidp when the container is a clash between two worlds world
Nahdi to promote world on the ashes , and often strained poet himself to achieve an approach
between worlds , and in the midst of those caesarean section exhausted poet in touch his tools
and visions , and this is why the poetry Hawi toward westernization expressive as a result of
the conflict concepts chronic , be sure to researcher not engaged in the overall qualitative
changes in the structure and content, but the goal Acetknah level that qualit