The standard formulation of Wave Intensity Analysis (WIA) assumes that the flow velocity (U) in the conduit is <;<; the velocity of propagation of waves (c) in the system, and Mach number, M=U/c, is negligible. However, in the large conduit arteries, U is relatively high due to ventricular contraction and c is relatively low due to the large compliance; thus M is > 0, and may not be ignored. Therefore, the aim of this study is to identify experimentally the relationship between M and the reflection coefficient in vitro. Combinations of flexible tubes, of 2 m in length with isotropic and uniform circular cross sectional area along their longitudinal axes, were used to present mother and daughter tubes to produce a range of reflection coefficients. An approximately semi-sinusoidal pulse was generated at the inlet of the mother tube using a syringe pump, first in the condition of initial velocity, U 0 =0, and when U 0 >0 with steady flow to superimpose the pulse. Pressure (P) and Velocity (U) were measured in the mother tube, wave speed was determined using the foot to foot and PU-loops methods. The theoretical reflection coefficient, R t at M=0, has been compared to the experimental reflection coefficient, R at M>0, which was determined as dP-/dP+ as calculated using WIA. The function R(M) changes significantly with the geometrical and mechanical features of the connected tubes. In our experiments, R increased significantly with small values of M. In the range of M=0-0.02, R increased by 4-36%. Therefore, we conclude that M significantly affects the magnitude of reflections.
Background: Male infertility is a global concern and it tends to increase due to miscellaneous factors, such as environmental toxins and genetic and lifestyle choices. The aryl hydrocarbon receptor (AHR) has recently attracted attention due to its involvement in male infertility mechanisms and impact on sperm production and function. AHR, a versatile receptor expressed in various tissues, including the testes, regulates the genes involved in spermatogenesis. AHR activation is associated with cell cycle regulation and chromatin condensation during spermatogenesis. Objectives: This study aimed to investigate the influence of AHR activation on blood-testis barrier (BTB) integrity, focusing on the role of tight junction protein-1 (TJP1)
... Show MoreThe poor hole cleaning efficiency could causes many problems such as high torque, drag, poor hydraulics and pipe stuck. These inherent problems result in an avoidable high operation cost which this study tried to address. In this study, the effect of cutting density on hole cleaning efficiency in deviated and horizontal wells was investigated. Experiments were conducted using 40 feet (12 m) long of flow loop made from iron and PVC. However, the test section was made from PVC with (5.1m) long and (4” ID) for outer pipe and (2” OD) inner pipe. The cutting transport ratio (CTR) was determined from weight measurements for each test. Cutting Transport Ratio has been investigated for effects of the following parameters; flow rate, cu
... Show MoreAn experimental and numerical investigation of the effect of using two types of nanofluids with suspending of (Al2O3 and CuO) nanoparticles in deionized water with a volume fraction of (0.1% vol.), in addition to use three types of fin plate configurations of (smooth, perforated, and dimple plate) to study the heat transfer enhancement characteristics of commercial fin plate heat sink for cooling computer processing unit. All experimental tests under simulated conditions by using heat flux heater element with input power range of (5, 16, 35, 70, and 100 W). The experimental parameters calculated are such as water and nanofluid as coolant with Reynolds number of (7000, 8000, 9400 and 11300); the air
... Show MoreThe potential application of granules of brick waste (GBW) as a low-cost sorbent for removal of Ni+2ions from aqueous solutions has been studied. The properties of GBW were determined through several tests such as X-Ray diffraction (XRD), Energy dispersive X-ray (EDX), Scanning electron microscopy (SEM), and BET surface area. In batch tests, the influence of several operating parameters including contact time, initial concentration, agitation speed, and the dose of GBW was investigated. The best values of these parameters that provided maximum removal efficiency of nickel (39.4%) were 1.5 hr, 50 mg/L, 250 rpm, and 1.8 g/100mL, respectively. The adsorption data obtained by batch experiments subjected to the Three i
... Show MoreThis research aims to Measurement provide the service from Two perspectives The first perspective Service Provider (doctors) and the second recipient of the service (patients) in Numan General Hospital, and represented the research problem in perceptions of medical staff in the hospital assigned to them responsibility by providing superior services satisfy customers, and how they maintained ready to assist customers and provide services that exceed their perceptions of these services through the use of the developer scale by (Frimpong and Wilson, 2012), includes orientation to provide the service scale four dimensions (Internal cooperative behaviors, service Competence, Service Responsiveness and Enhanced service) and includes do
... Show MoreAbstract. This study presents experimental and numerical investigation on the effectiveness of electrode geometry on flushing and debris removal in Electrical Discharge Drilling (EDD) process. A new electrode geometry, namely side-cut electrode, was designed and manufactured based on circular electrode geometry. Several drilling operations were performed on stainless steel 304 using rotary tubular electrodes with circular and side-cut geometries. Drilling performance was characterized by Material Removal Rate (MRR), Electrode Wear Rate (EWR), and Tool Wear Ratio (TWR). Dimensional features and surface quality of drilled holes were evaluated based on Overcut (OC), Hole Depth (HD), and Surface Roughness (SR). Three-dimensional
... Show MorePrior to the start of production, several factors must be considered, including the price, effectiveness, and environmental friendliness of batteries. Ionic liquids and deep eutectic solvents have shown significant success when employed as electrolytes with Titanium-graphite cells, especially when combined with additives that enhance their conductivity by reducing the high viscosity of these liquids. Evaluating the discharge voltage of the AlCl3-chloroacetamide IL with DCM as an additive revealed a voltage of 1.16V and an internal resistance of 11 Ohm. These electrochemical cells exhibited an intriguing response. Otherwise, when utilizing CaCl2.2H2O:
... Show More