This study explores the barriers to adopting green environmental criteria in Supplier Selection (SS) within the Iraqi food industry. It aims to enhance the understanding of sustainable supply chain management in developing nations, with a particular focus on the Iraqi context. A case study approach was utilized to identify eleven key green environmental criteria and 54 sub-criteria, alongside seven major barriers to their adoption. The Best–Worst Method (BWM) was employed to rank the criteria, and Fuzzy Stepwise Weight Assessment Ratio Analysis (SWARA) was used to prioritize the barriers. The analysis revealed that Environmental Management Systems are the most critical criterion for SS. On the other hand, legislation and policies emerged as the most significant barrier to adopting green environmental criteria. The findings provide valuable insights for managers and policymakers in Iraq, offering guidance on implementing sustainable supply chain practices. This study contributes to the growing build of knowledge on green supply chain management in developing countries.
Nanoparticles of humic acid and iron oxide were impregnated on the inert sand to produce sorbent for treating groundwater contained of cadmium and copper ions by technology of permeable reactive barrier (PRB). Sewage sludge was the source of the humic acid to prepare the coated sand by humic acid—iron oxide (CSHAIO) sorbent; so, this work is consistent with sustainable development. For 10 mg/L metal concentration, batch tests at speed of 200 rpm signified that the removal efficiencies are greater than 90% at sorbent dosage 0.25 g/ 50 mL, pH 6 and contact time 1 h. The kinetic data was well described by the Pseudo first-order model indicating that physicosorption is the predominant mechanism. The maximum adsorption capacities (qmax) were c
... Show MoreHerein, we report designing a new Δ (delta‐shaped) proton sponge base of 4,12‐dihydrogen‐4,8,12‐triazatriangulene (compound
Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show More