Fabrication of a photodetector consists of the conjugated polymer "MEH-PPV"- poly (2-methoxy-5-(2'-ethylhexyloxy)-1,4-phenlenevinylene) and MEH-PPV:MWCNT nanocomposite thin film. The volume ratio investigated was 0.75:0.25. MEH-PPV was dissolved in chloroform solvent and doped with MWCNTs. The spin coating method was used to achieve a facile and low cost photodetector. The absorption spectrum decreases by adding the CNTs. The PL spectrum detected recombination curve results by doping the polymer with CNTs, and AFM measurement showed an increase of roughness average from (0.168 to 2.43nm) of "MEH-PPV" and "MEH-PPV:CNTs", respectively. The doping ratio 0.25, which has a higher photoresponsivity, was evaluated at 1.70 A/W and 2.14 A/W of th
... Show MoreIn this work, plasma system that operates at vacuum was designed and built using a sheet of cobalt metal for the purpose of diagnosing plasma and measuring its parameters, as it is very important to know the processes that accompany plasma generation and are closely related to them, including the electron density in the plasma and its temperature. The spectroscopic diagnosis was done by optical emission spectroscopy (OES) which relies on the calculation of the optical radiation emitted by the plasma to describe plasma parameters in the chemical, molecular, and ionic radiator's near environment, and applied to cobalt metal at vacuum D.C high voltage power supply. The results showed the rise of spectral lines intensity with increa
... Show MorePeople may believe that tissue of normal brain and brain with benign tumor
have the same statistical descriptive measurements that are significantly different
from the of brain with malignant tumor. Thirty brain tumor images were collected
from thirty patients with different complains (10 normal brain images, 10 images
with benign brain tumor and 10 images with malignant brain tumor). Pixel
intensities are significantly different for all three types of images and the F-test was
measured and found equal to 25.55 with p-value less than 0.0001. The means of
standard deviations and coefficients of variation showed that pixel intensities from
normal and benign tumors images are almost have the same behavior whereas the
Background: Cerebral ventricular enlargement has been associated with many neurological disorders. Whether this enlargement is primary or secondary to these pathological conditions remains controversial. To define such enlargement, one must have measurements in normal subjects (controls).
Patients and methods: One hundred-twelve (66 male and 46 females) apparently healthy normal subjects, with age ranging between 10-69 years were subjected to C. T scans as part of routine diagnostic workup for complaint of headache or recent minor motor-vehichle accident The ratio (measured as percent) of the ventricular-cross area of the lateral ventricle The maximum width (MTW) of the third ventricle was also deter
The main goal of this work is to obtain the plasma electron temperature Te by optical emission spectroscopy of low pressure microwave argon plasma, as a function of working pressure and microwave power. A plasma system was designed and constructed in our laboratory using a magnetron of domestic microwave oven with power 800W without any commercial part. The applied voltage on the magnetron electrical circuit is changed for the purpose of obtaining the variable values of the microwave power. The spectral detection is performed with a spectrometer of wavelength range (200−1000nm). The working pressure and magnetron applied voltage were 0.3-3.0mbar and 180-240V, respectively. Two methods had been applied to estimate the electron temperatu
... Show MoreTotal Electron Content measurements derived from Athens station ionograms (ITEC),
located near Iraq, during the ascending phase of solar cycle 24 (July 2009- April 2010),
according to availability of data, are compared with the latest version of the International
Reference Ionosphere model, IRI-2012 (IRI TEC), using two options (NeQuick, IRI01-
Corr) for topside electron density.
The results obtained from both (ITEC and IRI TEC) techniques were similar, where
correlation coefficients between them are very high. Generally, the IRI predictions
overestimate the ITEC values.