Preferred Language
Articles
/
lhdALpEBVTCNdQwCm5P3
The Efficacy of Bedside Chest Ultrasound in the Detection of Traumatic Pneumothorax
...Show More Authors
Background

Chest X-rays have long been used to diagnose pneumothorax. In trauma patients, chest ultrasonography combined with chest CT may be a safer, faster, and more accurate approach. This could lead to better and quicker management of traumatic pneumothorax, as well as enhanced patient safety and clinical results.

Aim

The purpose of this study was to assess the efficacy and utility of bedside US chest in identifying traumatic pneumothorax and also its capacity to estimate the extent of the lesion in comparison to the gold standard modality chest computed tomography.

Methods

This was an observational cross-sectional study of 160 patients with traumatic pneumothorax. This sample was collected from all chest trauma patients admitted to Al-Kindy Teaching Hospital in Baghdad-Iraq between November 2021 and September 2022. Such patients were to have a bedside chest US and chest CT scan performed by a skilled radiologist to detect lung point signs and lung sliding, which would be used to determine the patient's pneumothorax status.

Results

According to the study's findings, about 77.5% of the patients evaluated were men. Furthermore, 40.6% of patients experienced blunt trauma. Chest ultrasound revealed positive pneumothorax in 50 cases (31.2%), while positive pneumothorax was confirmed by computed tomography in 53 cases (33.1%) with no significance in the detection of pneumothorax between the two imaging modalities p-value(0.719). Comparably, there was no significant difference in estimating the size of a pneumothorax between the two modalities (p-value = 0.547). Chest ultrasound diagnostic accuracy showed a sensitivity of approximately 92.45%, specificity of 99.07%, and diagnostic accuracy of 96.88%.

Conclusion

Our findings indicated that chest ultrasound might be a valuable rapid diagnostic tool for traumatic pneumothorax in the emergency department in addition to diagnosis. It eliminates the need to transport patients for a CT chest scan.

Scopus Crossref
View Publication
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Detection of Carbohydrate Antigen CA19-9 Levels in Sera and Tissues' Homogenate of Breast and Thyroid Benign Cases
...Show More Authors

         The aims of the present study are to evaluate the levels of CA19-9 in sera and tissues' homogenate of breast and thyroid benign patients in order to assess its use as an early diagnostic parameter in differentiation between malignant and benign cases. The study was conducted on 8 patients with breast benign tumor and 8 patients with thyroid benign tumor, by the enzyme linked immunosorbent assay (ELISA) technique. The results of CA19-9 levels in sera were (15 ±1.58 and 10.67 ±2.08)U/ml respectively compared with serum CA19-9 levels of control group which was 7.74 ±4.92 U/ml, the results were found to be highly significantly in breast tumor patients and non significantly in thyroid

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Food Chemistry
Development of cellulose Nanofiber-based substrates for rapid detection of ferbam in kale by Surface-enhanced Raman spectroscopy
...Show More Authors

View Publication
Scopus (31)
Crossref (29)
Scopus Clarivate Crossref
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Enhancement of gas response of annealed ZnO film for hydrogen gas detection
...Show More Authors

  The mechanism of hydrogen (H2) gas sensor in the range of 50-200 ppm of RF-sputtered annealed zinc oxide (ZnO) and without annealing was studied. The X-ray Diffraction( XRD) results showed that the Zn metal was completely converted to ZnO with a polycrystalline structure. The I–V characteristics of the device (PT/ZnO/Pt) measured at room temperature before and after annealing at 450 oC for4h, from which a linear relationship has been observed. The sensors had a maximum response to H2 at 350 oC for annealing ZnO and showed stable behavior for detecting H2 gases in the range of 50 to 200 ppm. The annealed film exhibited hig

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Use of cefoxitin as indicator for detection of Methicillin Resistant Staphylococcus aureus
...Show More Authors

Rapid and accurate identification of Methicillin Resistant Staphylococcus aureus is essential in limiting the spread of this bacterium. The aim of study is the detection of Methicillin Resistant Staphylococcus aureus (MRSA) and determining their susceptibility to some antimicrobial agent. A total of fifty clinical Staphylococcus aureus, isolated from the nose of health work staff in surgery unit of Kalar general hospital and from ear of patients attended to the same hospital. The susceptibilities of isolates were determined by the disc diffusion method with oxacillin (1 ?g) and cefoxitin (30 ?g), and by the mannitol salt agar supplemented with cefoxitin (MSA-CFOX), susceptibilities of isolates to other antimicrobial agent were determined b

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Dec 02 2019
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability
Effect of thickness variation CdO/PSi thin films on detection of radiation
...Show More Authors

CdO films were deposited on substrates from glass, Silicon and Porous silicon by thermal chemical spray pyrolysis technique with different thicknesses (130 and 438.46) nm. Measurements of X-ray diffraction of CdO thin film proved that the structure of the Polycrystalline is cubic lattice, and its crystallite size is located within nano scale range where the perfect orientation is (200). The results show that the surface’s roughness and the root mean square increased with increasing the thickness of prepared films. The UV-Visible measurements show that the CdO films with different thicknesses possess an allowed direct transition with band gap (4) eV. AFM measurement revealed that the silicon porosity located in nano range. Cadmium oxide f

... Show More
Scopus (3)
Scopus
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
edge detection using modification prewitt operators
...Show More Authors

in this paper we adopted ways for detecting edges locally classical prewitt operators and modification it are adopted to perform the edge detection and comparing then with sobel opreators the study shows that using a prewitt opreators

View Publication Preview PDF
Crossref
Publication Date
Fri Sep 23 2022
Journal Name
Specialusis Ugdymas
Intrusion Detection System Techniques A Review
...Show More Authors

With the high usage of computers and networks in the current time, the amount of security threats is increased. The study of intrusion detection systems (IDS) has received much attention throughout the computer science field. The main objective of this study is to examine the existing literature on various approaches for Intrusion Detection. This paper presents an overview of different intrusion detection systems and a detailed analysis of multiple techniques for these systems, including their advantages and disadvantages. These techniques include artificial neural networks, bio-inspired computing, evolutionary techniques, machine learning, and pattern recognition.

Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Shared Congestion Detection: A Comparative Study
...Show More Authors

Most Internet-tomography problems such as shared congestion detection depend on network measurements. Usually, such measurements are carried out in multiple locations inside the network and relied on local clocks. These clocks usually skewed with time making these measurements unsynchronized and thereby degrading the performance of most techniques. Recently, shared congestion detection has become an important issue in many computer networked applications such as multimedia streaming and
peer-to-peer file sharing. One of the most powerful techniques that employed in literature is based on Discrete Wavelet Transform (DWT) with cross-correlation operation to determine the state of the congestion. Wavelet transform is used as a de-noisin

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2020
Journal Name
Biochemical & Cellular Archives
THE STUDY ON ABILITY OF ESCHERICHIA COLI ISOLATED FROM DIFFERENT CLINICAL CASES TO BIOFILM FORMATION AND DETECTION OF CSGD GENE RESPONSIBLE FOR PRODUCE CURLI (FIMBRIAE)
...Show More Authors

A total of 165 clinical sample included Urine, Swab wounds and Burns were collected from Baghdad Governorate. Results showed that rate all isolates of E. coli was 50(30.3%) and rate of urine infection was 46(92%) and rate of swab wounds infection 4(8%). Where was diagnostic based on streaked on MacConkey agar, then single colony was transferred to Eosin Methylene Blue (EMB). Identification some of the biochemical test included: Catalase test, Oxidase test, Indole test, Methyl red, Vogues - Proskauer test and Citrate Utilization test. Then confirmed by the Vitek - 2 Compact System. The ability of E.coli isolate to biofilm formation to be studied it is considered one of the most important factors of virulence and has role in causing injury an

... Show More
Scopus (4)
Scopus
Publication Date
Fri Aug 15 2025
Journal Name
The Eurasia Proceedings Of Science Technology Engineering And Mathematics
Detection of Antimicrobial Activity of Aspergillus terreus Against Clinical Isolates of Serratia marcescens
...Show More Authors

Out of a total of fifty samples, thirty-five isolates were identified as Serratia marcescens. Thesediverse clinical samples were collected over a three-month period, from October 2023 to December 2023, fromseveral hospitals in Baghdad, including Fatima Al-Zahraa Hospital, Al-Sader Hospital, Ibn Al-Balady Hospital,and Al-Imam Ali Hospital. The clinical samples primarily included urine from patients with urinary tractinfections (UTIs). All isolates were cultured on nutrient agar, MacConkey agar, and blood agar, and theiridentities were confirmed through biochemical testing and the Vitek 2 compact system. Based on phenotypicvirulence factors, the S. marcescens isolates showed varying positive patterns: 32 out of 35 (91.42%) forprotease

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref