Urokinase plasminogen activator (uPA), urokinase plasminogen activator receptor (uPAR) and plasminogen activator inhibitor-1(PAI-1) are essential for metastasis, and overexpression of these molecules is strongly correlated with poor prognosis in a variety of malignant tumors. This study revealed direct correlation between immunohistochemical expression of uPA with pathological stage. No significant association of immunohistochemical expressions of uPA, uPAR and PAI-1 with immunohistochemical expressions for estrogen receptor (ER), progesterone receptor (PR) and human epidermal growth factor receptor -2 (HER-2/neu), and direct association between immunohistochemical expressions of (uPA and uPAR) as well as between immunohistochemical expr
... Show MoreMB Mahmood, BN Dhannoon
In this paper, we introduce a new digital authentication certification system to keep the classified documents' information safe. The proposed system is a steganography system divided into two subsystems, the first subsystem is responsible for embedding the information about the person, and it works in the main foundation that issues the documents, while the second subsystem is found in the beneficiary directorates to extract the true information of the person.
Among the different passive techniques heat pipe heat exchanger (HPHE) seems to be the most effective one for energy saving in heating ventilation and air conditioning system (HVAC). The applications for nanofluids with high conductivity are favorable to increase the thermal performance in HPHE. Even though the nanofluid has the higher heat conduction coefficient that dispels more heat theoretically but the higher concentration will make clustering .Clustering is a problem that must be solved before nanofluids can be considered for long-term practical uses. Results showed that the maximum value of relative power is 0.13 mW at nanofluid compared with other concentrations due to the low density of nanofluid at this concentration. For highe
... Show MoreThe use of a communication network in the closed loop control systems has many advantages such as remotely controlling equipment, low cost, easy to maintenance, efficient information transmission, etc. However, the Networked Control System (NCS) has many drawbacks, such as network-induce end-to-end time delay and packet loss, which lead to significant degradation in controller performance and may result in instability. Aiming at solving performance degradation in NCS, this paper propose to take the advantages and strength of the conventional Proportional-Integral-Derivative (PID), Fuzzy Logic (FL), and Gain Scheduling (GS) fundamentals to design a Fuzzy-PID like-Gain Scheduling (F-PID-GS) control technique, which has been proved to be ef
... Show MoreRecently personal recommender system has spread fast, because of its role in helping users to make their decision. Location-based recommender systems are one of these systems. These systems are working by sensing the location of the person and suggest the best services to him in his area. Unfortunately, these systems that depend on explicit user rating suffering from cold start and sparsity problems. The proposed system depends on the current user position to recommend a hotel to him, and on reviews analysis. The hybrid sentiment analyzer consists of supervised sentiment analyzer and the second stage is lexicon sentiment analyzer. This system has a contribute over the sentiment analyzer by extracting the aspects that users have been ment
... Show MoreSufficient conditions for boundary controllability of nonlinear system in quasi-Banach spaces are established. The results are obtained by using the strongly continuous semigroup theory and some techniques of nonlinear functional analysis, such as, fixed point theorem and quasi-Banach contraction principle theorem. Moreover, we given an example which is provided to illustrate the theory.
In this work, the design and implementation of a smart energy metering system has been developed. This system consists of two parts: billing center and a set of distributed smart energy meters. The function of smart energy meter is measuring and calculating the cost of consumed energy according to a multi-tariff scheme. This can be effectively solving the problem of stressing the electrical grid and rising consumer awareness. Moreover, smart energy meter decreases technical losses by improving power factor. The function of the billing center is to issue a consumer bill and contributes in locating the irregularities on the electrical grid (non-technical losses). Moreover, it sends the switch off command in case of the consumer bill is not
... Show MoreIn this work the parameters of plasma (electron temperature Te,
electron density ne, electron velocity and ion velocity) have been
studied by using the spectrometer that collect the spectrum of
plasma. Two cathodes were used (Si:Si) P-type and deposited on
glass. In this research argon gas has been used at various values of
pressures (0.5, 0.4, 0.3, and 0.2 torr) with constant deposition time
4 hrs. The results of electron temperature were (31596.19, 31099.77,
26020.14 and 25372.64) kelvin, and electron density (7.60*1016,
8.16*1016, 6.82*1016 and 7.11*1016) m-3. Optical properties of Si
were determined through the optical transmission method using
ultraviolet visible spectrophotometer with in the range
(