Nonlinear Buckling Analysis of Steel Cylindrical Shell with Elliptical Cut-out Subjected to Longitudinal Compressive Load
...Show More Authors

The current paper investigates the effect of cut-out design parameters on load-bearing capacity and buckling behaviour of steel cylindrical shell using a nonlinear finite element analysis in modelling cylinder buckling under longitudinal compressive load. The effect of four geometry design parameters: shell diameter to thickness ratio, cut-out location, orientation, and size were investigated in this study. To enhance the prediction of buckling behaviour, both geometrical and material nonlinearities were considered. An ANSYS APDL code was written and tested by verifying its validity through comparison with former buckling study. The results showed that changing the cut-out location from mid-height of the cylindrical shell towards a fixed edge caused an increase in the buckling load value. Moreover, the study showed that increasing parameters such as shell thickness and cut-out orientation have a positive influence in which the buckling load value increased too. For fast design purposes, an empirical numerical based regression formula was presented for the calculation of the critical buckling load of a cylindrical shell having an elliptical cut-out.

Scopus Crossref
View Publication
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Internal Convective Heat Transfer Effect on Iraqi Building Construction Cooling Load
...Show More Authors

This work involves the calculation of the cooling load in Iraqi building constructions taking in account the effect of the convective heat transfer inside the buildings. ASHRAE assumptions are compared with the Fisher and Pedersen model of estimation of internal convective heat transfer coefficient when the high rate of ventilation from ceiling inlet configuration is used. Theoretical calculation of cooling load using the Radiant Time Series Method (RTSM) is implemented on the actual tested spaces. Also the theoretical calculated cooling loads are experimentally compared by measuring the cooling load in these tested spaces. The comparison appears that using the modified Fisher and Pedersen model when large ventilation ra

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Ieee Systems Journal
Intelligent Traffic Management and Load Balance Based on Spike ISDN-IoT
...Show More Authors

An intelligent software defined network (ISDN) based on an intelligent controller can manage and control the network in a remarkable way. In this article, a methodology is proposed to estimate the packet flow at the sensing plane in the software defined network-Internet of Things based on a partial recurrent spike neural network (PRSNN) congestion controller, to predict the next step ahead of packet flow and thus, reduce the congestion that may occur. That is, the proposed model (spike ISDN-IoT) is enhanced with a congestion controller. This controller works as a proactive controller in the proposed model. In addition, we propose another intelligent clustering controller based on an artificial neural network, which operates as a reactive co

... Show More
Scopus (20)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Tue May 01 2018
Journal Name
Journal Of Engineering
Wind Interference Effect for Overall Design Load on Mid-Rise Building
...Show More Authors

The constructed building in the urban area is subject to wind characteristics due to the influence of surrounding buildings. The residential complexes currently being built in Iraq represent a case study for the subject of this research. Therefore, the objective of this study is to identify the interference effect because of adjacent buildings effects on the mid-rise building. The speed and pressure of the wind have been numerically simulated as well as wind load has been simulated by using a virtual wind tunnel which is available in Autodesk Robot Structural Analysis, RSA, software. Two identical adjacent buildings have been simulated and many coefficients were included in this study such as the spacing, directionality,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Results In Engineering
Implementation of a control and monitoring system for a cathodic protection cell to mitigate localized corrosion in fixed and mobile steel structures
...Show More Authors

View Publication
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Results In Engineering
Implementation of a control and monitoring system for a cathodic protection cell to mitigate localized corrosion in fixed and mobile steel structures
...Show More Authors

The current study introduces a novel technique to handle electrochemical localized corrosion in certain limited regions rather than applying comprehensive cathodic protection (CP) treatment. An impressed current cathodic protection cell (ICCPC) was fabricated and firmly installed on the middle of a steel structure surface to deter localized corrosion in fixed or mobile steel structures. The designed ICCPC comprises three essential parts: an anode, a cathode, and an artificial electrolyte. The latter was developed to mimic the function of the natural electrolyte in CP. A proportional-integrated-derivative (PID) controller was designed to stabilize this potential below the ICCPC at a cathodic potential of −850 mV, which is crucial for prote

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
RELIABILITY ANALYSIS OF THE SEISMIC STABILITY OF EMBANKMENTS REINFORCED WITH STONE COLUMNS
...Show More Authors

Geotechnical engineers have always been concerned with the stabilization of slopes. For this purpose,
various methods such as retaining walls, piles, and geosynthetics may be used to increase the safety factor of slopes prone to failure. The application of stone columns may also be another potential alternative for slope stabilization. Such columns have normally been used for cohesive soil improvement. Most slope analysis and design is based on deterministic approach i.e a set of single valued design parameter are adopted and a set of single valued factor of safety (FOS) is determined. Usually the FOS is selected in view of the understanding and knowledge of the material parameters, the problem geometry, the method of analysis and the

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Baghdad Science Journal
Dynamic Response of a Nonlinear Fabry-Perot Etalon for Various Medium Response Times
...Show More Authors

     In this work, the switching nonlinear dynamics of a Fabry-Perot etalon are studied. The method used to complete the solution of the differential equations for the nonlinear medium. The Debye relaxation equations solved numerically to predict the behavior of the cavity for modulated input power. The response of the cavity filled with materials of different response time is depicted. For a material with a response time equal to = 50 ns, the cavity switches after about (100 ns). Notice that there is always a finite time delay before the cavity switches. The switch up time is much longer than the cavity build-up time of the corresponding linear cavity which was found to be of the order of a few round-trip ti

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Mar 30 2024
Journal Name
Journal Of Kufa For Mathematics And Computer
Approximate Solution of Linear and Nonlinear Partial Differential Equations Using Picard’s Iterative Method
...Show More Authors

Publication Date
Thu Oct 01 2020
Journal Name
Alexandria Engineering Journal
The operational matrix of Legendre polynomials for solving nonlinear thin film flow problems
...Show More Authors

Scopus (14)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Tue Mar 01 2016
Journal Name
Optics Communications
Temperature effect on nonlinear refractive indices of liquid crystals in visible and NIR
...Show More Authors

View Publication
Scopus (12)
Crossref (12)
Scopus Clarivate Crossref