Arterial aneurism and stenosis are disorders that lead to circulation malfunction. Stenosis often leads to hypoxia of the organ depending on the affected artery, whilst aneurism can lead to dissection with known lethal consequences. On both cases, the pulse wave produced by the contracting heart is reflected at these discontinuities, and estimating the size of these reflected waves using wave intensity analysis (WIA) is the main aim of this work. We also aim to measure wave speed, or pulse wave velocity (PWV) as more commonly known within the discontinuities. We manufactured 4 stenosis and 4 aneurism silicon sections, connected one at a time to a mother tube, and tested in vitro. Pressure and flow were measured proximal to the discontinuity and were used to calculate WIA. PWV was calculated using the foot to foot technique and also the classical Moens-Korteweg and Bramwell-Hill equations. Wave speed in an aneurism decreases, whereas it increases in a stenosis, all compared to the values determined in a standard mother tube. Presence of aneurisms resulted in a backward expansion whilst the presence of stenosis resulted in a backward compression wave, which related linearly to the size of the discontinuity. Larger aneurisms and smaller stenosis cause an increase in wave reflection.
Table tennis is considered one of the fast base sports that the player needs to have the speed of performance and awareness, especially in straight forward and back strikes, which is an important offensive skills, and the player success depends on his perception speed to the point of the fall of the ball in the arena of his competitor. But there is no way to measure cognitive processing speed. Therefore, the researchers sought to design a test that measures this ability to ensure its scientific evaluation, and then establish standard scores for this test for the players of the specialized school of table tennis, to help evaluate them objectively and move away from subjective estimates when evaluating and developing measuring instruments in
... Show MoreTrajectory tracking and vibration suppression are essential objectives in a flexible joint manipulator control. The flexible joint manipulator is an under-actuated system, in which the number of control actions is less than the degree of freedom to be controlled. It is very challenging to control the underactuated nonlinear system with two degree of freedom. This paper presents a hierarchical sliding mode control (HSMC) for a rotary flexible joint manipulator (RFJM). Firstly, the rotary flexible joint manipulator is modeled by two subsystems. Secondly, the sliding surfaces for both subsystems are constructed. Finally, the control action is designed based on the Lyapunov function. Computer simulation results demonstrate the effectiveness of
... Show MoreVarious semantic innovations and expansions have been tackled as factors and sources of neos. A variety of internal (linguistic) and external (extra-linguistic) motives and motifs leads to the appearance of new terms causing such changes in the political language. Some statesmen are productive in introducing new terms and creative in manipulating expressions and meanings.
New words are nonces that get metaphorical expansion for quadrilateral motivations resting on extra meaning innovation, new terms at the semantic expansions to be honed as neos. In tracing the phases of the semantic processes of neos and hulks, lexical and semantic changes might be of widening or narrowing of refe
... Show MoreReflections are ubiquitous effects in photos taken through transparent glass mediums, and represent a big problem in photography that impacts severely the performance of computer vision algorithms. Reflection removal is widely needed in daily lives with the prevalence of camera-equipped smart phones, and it is important, but it is a hard problem. This paper addresses the problem of reflection separation from two images taken from different viewpoints in front of a transparent glass medium, and proposes algorithm that exploits the natural image prior (gradient sparsity prior), and robust regression method to remove reflections. The proposed algorithm is tested on real world images, and the quantitative and visual quality comparisons were
... Show MoreRecently, that there has been a decline in the levels of female players for this event in recent years compared to developments in the world, as this activity depends to achieve the highest level of performance on the physical capabilities and physiological indicators of the player who It is reflected in the achievement, which results in the loss of time for Iraqi female runners compared to the world champions in the (100) meter hurdles competition, which reflects on the level of achievement. The two researchers used the experimental approach in addressing the research problem, and the experimental design used the method of the two equal groups, the two experiments with the pre and post-tests. Female runner and second experimental group (4)
... Show MoreThe study aims to identify the metamemory and perceptual speed among College students, the correlation between metamemory and perceptual speed among College students, and to which extend does metamemory contribute to perceptual speed among College students. The sample consisted of group of students were selected randomly by the researcher from five-different disciplines at the college of education for pure sciences. To collect study data, the researcher utilized two scales: perceptual speed scale that has translated to Arabic language by (Al-Shraqawi, Al- Shaikh, and Nadia Abed Al-Salam (1993). The second scale is metamemory scale (2002) which has translated to Arabic by Abu Ghazal (2007). The results revealed that college students have
... Show MoreBackground: Aortic valve stenosis results from minor to severe degrees of aortic valve maldevelopment. This stenosis causes mild to severe obstruction of the left ventricular outflow .
Objectives : to study the immediate and intermediate results of percutaneous balloon aortic valvuloplasty in patients with congenital valvular aortic stenosis .
Type of the study: A prospective study.
Methods: The study was done on thirty five patients with congenital valvular aortic stenosis who had percutaneous balloon aortic valvuloplasty in Ibn Al- Bitar Center for Cardiac Surgery from May 2009 to February 2011.
Results
... Show More