Preferred Language
Articles
/
kxbioYgBVTCNdQwCa3nd
The Role of Tibialis Posterior Tendon Transfer in Correction of Foot Drop Deformity
...Show More Authors

Backgr ound: The transfer of the tibialis posterior tendon to the anterior aspect of the ankle not only replaces the function of the paralyzed muscles, but also removes the deforming force on the medial aspect of the foot. Objecti ves: In this study, we evaluated patients who underwent tibialis posterior tendon transfer for the treatment of foot drop, and comparison through interosseous membrane route versus anterior to lower tibia route of tibialis posterior tendon transfer, with evaluation of the results according to carayon criteria Methods: Nine patients with foot drop secondary to different causes treated with tibialis posterior tendon transfer from January 2011 to January 2012 were followed up for a mean of 12 months in Al Kindy Teaching Hospital. We use two different techniques, first transfer the tendon through the interosseous membrane (four patients), and the second technique transfer the tendon anterior to tibia (five patients). Result s: In general according to carayon evaluation criteria, the results were excellent in two patients (22.2%), good in five patients (55.6%), and moderate in two patients (22.2%). Through anterior to lower tibia route, 4 patients get excellent to good result (80%), and through interosseous route, 3patients get good to excellent result (75%). Conclusions: Transfer of tibialis posterior tendon for the treatment of foot drop deformity enables the patients to walk without the aid of orthosis and increase their quality of life. With no differences between anterior to lower tibia route and through interosseous membrane route

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jul 01 2022
Journal Name
Journal Of Engineering
Conjugate Heat Transfer of Laminar Air Flow in Rectangular Mini Channel
...Show More Authors

Conjugate heat transfer has significant implications on heat transfer characteristics, particularly in thick wall applications and small diameter pipes. In this study, a three-dimensional numerical investigation was carried out using commercial CFD software “ANSYS FLUENT” to study the influence of conjugate heat transfer of laminar flow in mini channels at constant heat flux wall conditions. Two parameters were studied and analyzed: the wall thickness and thermal conductivity and their effect on heat transfer characteristics such as temperature profile and Nusselt number. Thermal conductivity of (0.25, 10, 202, and 387) W/m2C and wall thickness of (1, 5, and 50) mm were used for a channel of (1*2) mm cross

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 02 2011
Journal Name
Journal Of Educational And Psychological Researches
School s’ Violence and its relation to academic Failed and School s’ Drop - Out among Intermediate stage Pupils
...Show More Authors

The present research aims to know the relation of Violence on academic Failed and School s’ Drop - out among Intermediate stage Pupils. The sample of the research reached (400) male and female pupils (failed and not failed ), and (69) male and female that Drop – out from Intermediate stage. The researcher used scale of Violence that constructed by (AL- qaysi , 2004) after she got Validity and Reliability to it . So that she used t- test for one sample, t- test for two independent sample, and Person correlation coefficient as a statistical means. The research reached to the results that indicates raising of level of Violence among the Intermediate stage pupils (failed and not failed) and the male and female that Drop – out from Inte

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
A COMPARATIVE STUDY OF THE AMOUNT OF FORCE EXERTED ON THE GROUND AND THE TIME OF PROPULSION IN THE VERTICAL AND HORIZONTAL JUMPING TESTS FROM STABILITY USING A FOOT SCAN DEVICE
...Show More Authors

Publication Date
Sun Apr 08 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental Investigation of the Effect of Curvature Ratio on Heat Transfer in Double Pipe Helical Heat Exchanger
...Show More Authors

Different parameters of double pipe helical coil were investigation experimentally. Four coils were used; three with a curvature ratio (0.037, 0.031, and 0.028) and 11mm diameter of the inner tube while the fourth with 0.033 curvature ratio and 13 mm diameter of the inner tube. The hot water flow in the inner tube whereas the cold water flows in the annulus. The inlet temperatures of hot and cold water are 50 0C and 18 0C respectively. The inner mass flow rate ranges from 0.0167 to 0.0583 kg/s. The results show the Nusselt number increase with increase curvature ratio. The Nusselt number of the coil with 0.037 curvature ratio increases by approximately 12.3 % as compare with 0.028 curvature ratio. The results also r

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Engineering
Estimation of Mass Transfer Coefficient for Copper Electrowinning Process
...Show More Authors

Mass transfer was examined at a stationary rectangular copper electrode (cathode) by using the reduction of cupric ions as the electrochemical reaction. The influence of electrolyte temperature (25, 45, and 65 oC), and cupric ions concentration (4, 8, and 12 mM) on mass transfer coefficient were investigated by using limiting current technique. The mass transfer coefficient and hence the Sherwood number was correlated as Sh =

 

View Publication Preview PDF
Publication Date
Tue Dec 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Heat Transfer Efficiency of Different Composite Insulators
...Show More Authors

This research aims to investigate the thermal performance of different thermal composite insulators, wrapped around a closed-loop copper pipe (CLP). To achieve this aim a system was designed and manufactured. It is consisted of closed water tank insulated by Rock Wool, and supplied with two electric heaters, two thermostat, a flow meter, a water pump, digital temperature scales, and four series of (CLP).
Six insulators were prepared namely; composites of Impregnated Fiberglass with Elastoclad and foaming Rubber (FER), Impregnated Fiberglass with Elastoclad resin and Polymeric Membrane (FEM), Impregnated Fiberglass with Polyurethane thermoset resin and Foaming Rubber (FUR), Impregnated Fiberglass with Polyurethane thermoset resin and P

... Show More
View Publication Preview PDF
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Investigating of Charge Transfer in Cu/F8 Using Donor-Acceptor Model due Quantum Transition
...Show More Authors

in this paper, we study and investigate a simple donor-acceptor model for charge transfer formation using a quantum transition theory. The transfer parameters which enhanced the charge transfer and the rate of the charge transfer have been calculated. Then, we study the net charge transfer through interface of Cu/F8 contact devices and evaluate all transfer coefficients. The charge transfer rate of transfer processes is found to be dominated in the low orientation free energy and increased a little in decreased potential at interface comparison to the high potential at interface. The increased transition energy results in increasing the orientation of Cu to F8. The transfer in the system was more active when the system has large driving for

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Sun Jun 01 2008
Journal Name
Al-khwarizmi Engineering Journal
Hydrodynamics, Mass and Heat Transfer in Reactive Distillation
...Show More Authors

      The ethyl acetate synthesis via heterogeneous reactive distillation is studied experimentally using ethanol and acetic acid. Three types of cation exchanging resins were used as catalysts: Zerolit 225, Zerolit 226 and Ambylite 400. Experiments were carried out in two units of the same dimensions. Each unit consisted of three sections: rectifying, reactive and stripping sections of heights (60+25+20) cm respectively and 2.5cm column diameter. The first unit (column-A-) was a fractionation type and the second unit (column-B-) was packed column. The packing type was hollow glass cylinders with 10 mm height, and 4, 5 mm inner and outer diameter respectively.

      The experiment

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 26 2021
Journal Name
Series On Biomechanics
Monitoring and analysis of plantar pressure map and foot motions using a wearable sensing system
...Show More Authors

Peer-Reviewed Journal

View Publication
Scopus (4)
Scopus
Publication Date
Sat Dec 31 2022
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
THE ROLE OF EFFLUX PUMP FOR ANTIBIOTIC RESISTANCE IN BACTERIA: THE ROLE OF EFFLUX PUMP FOR ANTIBIOTIC RESISTANCE IN BACTERIA
...Show More Authors

ABSTRACT                

The multi-drug resistant efflux pump is a glycoprotein pump whose function is to push foreign substances. The efflux pump is found in humans, animals. It also has wide-ranging properties in  bacteria and fungi. They are found in all species of bacteria, and efflux pump genes can be found in bacterial chromosomes or mobile genetic elements, such as plasmids. The most sensitive function that leads to a global problem is its resistance to antibiotics in bacterial cells, which increases the ability to bacteria from becoming strong virulence factors that most or all antibiotics cannot kill. It also has othe

... Show More
View Publication Preview PDF