Introduction The Hybrid Gamma Camera (HGC) is being developed to enhance the localisation of radiopharmaceutical uptake in targeted tissues during surgical procedures such as sentinel lymph node (SLN) biopsy. Purpose To assess the capability of the HGC, a lymph-node-contrast (LNC) phantom was constructed for an evaluative study simulating medical scenarios of varying radioactivity concentration and SLN size. Materials and methods The phantom was constructed using two methyl methacrylate PMMA plates (8 mm thick). The SLNs were simulated by drilling circular wells of diameters ranging between 10 mm and 2.5 mm (16 wells in total) in one plate. These simulated SLNs were placed underneath scattering material with thicknesses ranging between 5 mm and 40 mm. The second plate contains four rectangular wells to simulate background activity uptake surrounding the SLNs. The activity used ranged between 4 MBq and 0.025 MBq for the SLNs. The background activity was 1/10 of the SLNs activity. The collimator to source distance was 120 mm. Results Signal to Noise Ratio (SNR) analysis and spatial resolution measurements of the simulated SLN were used to compare the imaging sets over acquisition times ranging between 60s and 240s. The HGC successfully detected 87.5% to 100% of the SLNs through 20mm of scattering material, and it could detect 75% to 93.75% of the SLNs through 40mm of scattering material. Measurement of Full-Width-at-Half-Maximum (FWHM) for the detected SLNs ranged between 9.5 mm and 12 mm. Conclusion The HGC is capable of detecting low activity uptake in small SLNs indicating its usefulness as an intraoperative imaging system during surgical SLN procedures.
Nowadays, most of the on-chip plasmonic single-photon sources emit an unpolarized stream of single photons that demand a subsequent polarizer stage in a practical quantum cryptography system. In this paper, we numerically demonstrated the coupling of the light emitted from a quantum emitter (QE) at 700 nm wavelength to the propagation mode supported by an on-chip hybrid plasmonic waveguide (HPW) polarization rotator. Our results proved that the light emitted is linearly polarized at 0º, 45º/−45º, and 90º with propagation lengths of 5 μm, 3.3 μm, and 3.9 μm, respectively. Moreover, high power-conversion efficiency was obtained from an applied transverse magnetic (TM) mode (0º-polarization) to a transverse electric (TE) (90º-polari
... Show More—Medical images have recently played a significant role in the diagnosis and detection of various diseases. Medical imaging can provide a means of direct visualization to observe through the human body and notice the small anatomical change and biological processes associated by different biological and physical parameters. To achieve a more accurate and reliable diagnosis, nowadays, varieties of computer aided detection (CAD) and computer-aided diagnosis (CADx) approaches have been established to help interpretation of the medical images. The CAD has become among the many major research subjects in diagnostic radiology and medical imaging. In this work we study the improvement in accuracy of detection of CAD system when comb
... Show MoreThis paper proposes a compact, plasmonic-based 4 × 4 nonblocking switch for optical networks. This device uses six 2 × 2 plasmonic Mach-Zehnder switch (MZS), whose arm waveguide is supported by a JRD1 polymer layer as a high electro-optic coefficient material. The 4 × 4 switch is designed in COMSOL environment for 1550 nm wavelength operation. The performance of the proposed switch outperforms those of conventional (nonplasmonic) counterparts. The designed switch yields a compact structure ( 500 × 70 µ m 2 ) having V π L = 12 V · µ m , 1.5 THz optical bandwidth, 7.7 dB insertion loss, and −26.5 dB crosstalk. The capability of the switch to route 8 × 40 Gbps WDM signal is demonstrated successfully.
... Show MoreThis research aims to investigate and improve multi-user free space optic systems (FSO) based on a hybrid subcarrier multiplexing spectral amplitude coding-optical code division multiple access (SCM-SAC-OCDMA) technique using MS code with a direct decoding technique. The performance is observed under different weather conditions including clear, rain, and haze conditions. The investigation includes analyzing the proposed system mathematically using MATLAB and OptiSystem software. The simulation is carried out using a laser diode. Furthermore, the performances of the MS code in terms of angles of bit rate, beam divergence and noise are evaluated based on bit error rate (BER), received
In this paper, an experimental study of the thermal performance for hybrid solar air conditioning system was carried out, to investigate system suitability for the hot climate in Iraq. The system consists of vapor compression unit combined with evacuated tube solar collector and liquid storage tank. A three-way valve was installed after the compressor to control the direction flow of the refrigerant, either to the storage tank or directly to the condenser. The performance parameters were collected by data logger to display and record in the computer by using LabVIEW software. The results show that the average coefficient of performance of hybrid solar air conditioning system (R=1) was about 2.42 to 2.77 and the average p
... Show More