The chemicals materials were used to study the effect of citric acid, detergents, sodium carbonate, sodium bicarbonate on the vitality of the third stage of mosquito Culex pipiens molestus. The highest larvicidal efficacy was established from citric acid solution followed by detergents solution, sodium carbonate, sodium bicarbonate with (LC50) values 2096, 2715, 13930, 13960 ppm respectively. The concentration of 1000 ppm of citric acid showed a fatal effect on the third stage larvae of mosquitoes which gave a mortality percent of 100% on the second day of the treatment. It was followed by the concentrations of 750 ppm and 500 ppm respectively which caused the death of all larvae on the fifth and sixth days respe
... Show MoreThe effectiveness inhibitory to extract alcohol for the leaf and flower to plant sage Salvia pratensis each of Staphylococcus aureus, streptococcus epidermidis, Salmonella typhi, Pseudomonas aeroginosa, Escherichia coli, Aspergillus niger and Candida albicans whom had any inhibition to aqueous extracts of the parts itself species bacterial and fungal. The study also demonstrated that the extract of plant containing compounds chemical such as tannins, Alkaloids, Flavonoieds, and saponins, which owns effectiveness of medical. The MIC, MBC and inhibition zones for crud extract were determinated for microbial agents.
The current study was concerned with the effect of alkaloid extract of the aerial parts of Capparis spinosa against Entamoeba histolytica and compared with drug Metronidazole in the laboratory mice .Stool samples were collected from people infected with maebiasis to infect laboratory mice . The alkaloid compounds were separated by thin chromatography technique (TLC) and identified by spectral methods represented by spectral infrared (IR) and altraviolate (UV) . the stady include determining mid-term lethal dose LD50 of the extract as the concentration was 21.65 g / kg . The effect dose of the extract was tested on the infected experimental mice with Entamoeba histolytica after 10 days of the infection compared with the mice infected
... Show MoreIn recent years, infectious diseases are increasingly being encountered in clinical settings. Due to the development of antibiotic resistance and the outbreak of these diseases caused by resistant pathogenic bacteria, the pharmaceutical companies and the researchers are now searching for new unconventional antibacterial agents. Recently, in this field, the application of nanoparticles is an emerging area of nanoscience and nanotechnology. For this reason, nanotechnology has a great deal of attention from the scientific community and may provide solutions to technological and environmental challenges. A common feature that these nanoparticles exhibit their antimicrobial behavior against pathogenic bacteria. In this report, we evaluate
... Show MoreBackground: the activity of acute lymphoblastic leukemia had been observed to correlate with levels of serum lipoproteins
Objective: to evaluate the correlation of serum levels of different types of lipoproteins with activity of the disease in patients with acute lymphoblastic leukemia.
Type of the study: A prospective study.
Methods: A study included patients diagnosed as acute lymphoblastic leukemia, their serum levels of lipoproteins at time of diagnosis, and on relapse were obtained for comparison.
Results: there is significant inverse correlation of activity of acute lymphoblastic leukemia with serum total cholesterol
... Show MoreSolar activity monitoring is important in our life because of its direct or indirect influence on our life, not only on ionospheric communications. To study solar activity, researchers need measuring and monitoring instruments, these instruments are mostly expensive and are not available in all universities. In this paper, a very low frequency radio receiver had been designed and implemented with components available in most markets to support the researchers, college students, and radio astronomy amateurs with a minimum input voltage less than 100µV, an output voltage less than 135 m V with no distortion and an overall gain of 34dB. A comparison had been done between two circuit structures using a workbench software program and experim
... Show MoreNew, simple and sensitive batch and reverse FIA spectrophotometric methods for the determination of doxycycline hyclate in pure form and in pharmaceutical preparations were proposed. These methods based on oxidative coupling reaction between doxycycline hyclate and 3-methylbenzothiazolinone-2-hydrazone hydrochloride (MBTH) in the presence ammonium ceric sulfate in acidic medium, to form green water-soluble dye that is stable and has a maximum absorbance at 626 nm. A calibration graph shows that a Beer's law is obeyed over the concentration range of 1-80 and 0.5-110 ?g.mL-1 of DCH for the batch and rFIA respectively with detection limit of 0.325 ?g.mL-1 of DCH for r-FIA methods. All different chemicals and physical experimental paramete
... Show MoreThe study of the validity and probability of failure in solids and structures is highly considered as one of the most incredibly-highlighted study fields in many science and engineering applications, the design analysts must therefore seek to investigate the points where the failing strains may be occurred, the probabilities of which these strains can cause the existing cracks to propagate through the fractured medium considered, and thereafter the solutions by which the analysts can adopt the approachable techniques to reduce/arrest these propagating cracks.In the present study a theoretical investigation upon simply-supported thin plates having surface cracks within their structure is to be accomplished, and the applied impact load to the
... Show MoreA simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the
... Show More