We studied at the morphology, structural setup, and optical characteristics of thin cadmium (CdSe) films a thickness of 250 nm that were created by thermal evaporation over glass, The films exhibited a hexagonal shape were crystalline, and tended to form grains in the (111) crystallographic direction, according to the X-ray diffraction examinations. These characteristics were established using the investigation's findings. Through the use of thin films of CdSe doped with Ag at a concentration of 1.5%, the crystal structure orientations for pure CdSe (25.32, 41.84) and CdSe:Ag (25.39, 41.01) that were both pure as well as those that were doped with silver were both determined. The band gap of the optical spectrum decreased by 1.93–1.81 eV (300–700 nm). This reduced the rate of absorption measuring the current-voltage properties of heterojunctions made from a range of clean and doped materials with an incident electrical power density of (100 mW/cm2 ). The films' hexagonal structure was revealed by the X-ray investigation, and grain development was driven by the (220,111) crystallographic direction.
Cadmium oxide CdO thin films were prepared by successive ionic layer adsorption and reaction (SILAR) technique at varying number of dippings. The CdO thin films were prepared from a source material of Cadmium acetate and ammonium hydroxide solution deposited on glass substrate at 95℃. The prepared thin films were investigated by X-ray diffraction (XRD), Atomic force microscopy (AFM), Scanning Electron Microscopy (SEM), Fourier Transform Infrared (FTIR), and UV-Visible spectrometry. The XRD analysis reveals that the films were polycrystalline with cubic structure having preferential orientation along (1 1 1), (2 0 0), (2 2 0), and (3 1 1) planes. While the tests of the scanning electron microscopy and the atomic force mic
... Show MoreA newly flow injection-turbidimetric method characterized by it is speed and sensitivity has been developed for the determination of Amiloride in pure and pharmaceutical preparations. It is based on the formation of yellowish white precipitate for the Amiloride-phosphomolybidic acid ion pair in aqueous medium. Turbidity was measured by Ayah 6Sx1-T-1D solar cell CFI analyser via the attenuation of incident light from the surfaces precipitated particles at 0-180. The Chemical and physical parameters were investigated. Linear dynamic range for the attenuation of incident light versus Amiloride concentration was of 0.005-10 mmol.L-1, with the correlation coefficient (r) of 0.9986 , while the percentage linearity (r2%) was 99.71%. The L.O.
... Show MoreA newly flow injection-turbidimetric method characterized by it is speed and sensitivity has been developed for the determination of Amiloride in pure and pharmaceutical preparations. It is based on the formation of yellowish white precipitate for the Amiloride-phosphomolybidic acid ion pair in aqueous medium. Turbidity was measured by Ayah 6Sx1-T-1D solar cell CFI analyser via the attenuation of incident light from the surfaces precipitated particles at 0-180. The Chemical and physical parameters were investigated. Linear dynamic range for the attenuation of incident light versus Amiloride concentration was of 0.005-10 mmol.L-1, with the correlation coefficient (r) of 0.9986 , while the percentage linearity (r2%) was 99.71%. The L.O.
... Show MoreBackground: The importance of essential trace elements plays a major role in medicine mainly cardiovascular diseases.
Methods: The study involved 305 patients with either myocardial infarction ( MI ) , angina pectoris ( AP ) or hypertension ( HT ) for evaluation of these trace elements level ( Se & Cr ) as compared with 100 control subjects in Ibin Al Bitar hospital for cardiac surgery between July 2003 and May 2005 by using Atomic Absorption Spectrophotometer ( AAS ) done in the laboratories of ministry of Sciences and Technology in Baghdad.
Result: The total numbers of patients enrolled in this study were 305 patients, Ml contributes to 70 patients, 55 male and 25 female with
A new, simple, accurate, fast and sensitive spectrophotometric method has been developed for the analysis of amiloride in pure and pharmaceutical formulations by continuous flow injection analysis. The method was based on the oxidation of the drug with Ce(IV)sulfate in acidic medium to formed a pinkish-red color species which determined using homemade Ayah 3SBGR x3-3D solar cell flow injection photometer. Optimum conditions were obtained using a high intensity green light emitted diode as a source. The linear dynamic range for the instrument response versus amiloride concentration was 0.0005- 10 mmol.L-1 while the L.O.D was of 9.471 ng / sample. The correlation coefficient (r) was 0.9824 while percentage linearity (r2%) was 96.50%. RSD%
... Show MoreIn the present work, a Z-scan technique was used to study the nonlinear optical properties, represented by the nonlinear refractive index and nonlinear absorption coefficients of the Ag nanoparticles. In this technique, a pulsed second harmonic Nd :YAG laser at wavelength 532 nm was used. The results show that the nonlinear refractive index and nonlinear absorption coefficients of the Ag nanoparticles are found to be dependent on the size these nanoparticles.
The important aspect of this unconventional approach is that eco-friendly, commercially available and straight forward method was used to prepared Silver Nanoparticles by using AgNO3 and curcumin solution as agent factor. The (TEM), (XRD), and (FTIR) was used to characterise these silver nanoparticles (AgNPs). Two types of bacterial isolates were used to indicate the antibacterial activity silver nanoparticles which prepared by curcumin solution, Gram negative like (Escherichia Coli E. Coli), & Gram positive (Stapha Urous). The results exhibit that silver nanoparticles synthesized by curcumin solution has effective antibacterial activities.
This study was done to compare among 120 new and used cosmetic brands to determine the heavy metals concentrations (Cadmium, Chromium) in (face foundation, powder and blushers). Sixty new cosmetic products were bought from local markets in Baghdad city (twenty different brands foe each cosmetic products), while sixty used cosmetic products were collected from Iraqi women and they had been stored for a long time. This study proved that not all analyzed cosmetic products containing heavy metals concentrations and all concentrations are under Iraqi acceptable limits except one new blusher product which contained chromium with (28 ppm), but all used cosmetic products have shown better results in concentrations of heavy metals than new produc
... Show MoreBackground: Cadmium (Cd) is an industrial and environmental pollutant that affect adversely a number of organs in humans and other mammals.
Objectives: To study the effect of cadmium on liver of mice.
Material and Methods: Male Balb/c mice weighing 30-32 gm, 60 days old, were treated intraperitoneally (ip) with (1-10mg/kg body wt. /CdCl2). The body weight, liver weight, histological examination of liver, SEM, metal analysis along with DNA ladder for apoptosis.
Results: Cadmium induced both a time, and dose dependent increase in apoptotic, severity of necrosis. Liver weight, body weight decreased with increase of dose, while metal content was increased by increase of dose.
Conclusion: It has been concluded that cadmium caused
The biosorption of Pb (II), Cd (II), and Hg (II) from simulated aqueous solutions using baker’s yeast biomass was investigated. Batch type experiments were carried out to find the equilibrium isotherm data for each component (single, binary, and ternary), and the adsorption rate constants. Kinetics pseudo-first and second order rate models applied to the adsorption data to estimate the rate constant for each solute, the results showed that the Cd (II), Pb (II), and Hg (II) uptake process followed the pseudo-second order rate model with (R2) 0.963, 0.979, and 0.960 respectively. The equilibrium isotherm data were fitted with five theoretical models. Langmuir model provides the best fitting for the experimental results with (R2) 0.992, 0
... Show More