Preferred Language
Articles
/
kRYwFYcBVTCNdQwCGTVo
EFFECT OF ZRO2 , WO3 ADDITIVES ON CATALYTIC PERFORMANCE OF PT/HY ZEOLITE COMPARED WITH PT/ΓAL2O3 FOR IRAQI NAPHTHA TRANSFORMATION
...Show More Authors

Light naphtha treatment was achieved over 0.3wt%Pt loaded-alumina, HY-zeolite and Zr/W/HY-zeolite catalysts at temperature rang of 240-370°C, hydrogen to hydrocarbon mole ratio of 1-4 0.75-3 wt/wt/hr, liquid hourly space velocity (LHSV) and at atmospheric pressure. The hydroconversion of light naphtha over Pt loaded catalyst shows two main reactions; hydrocracking and hydroisomerization reactions. The catalytic conversion of a light naphtha is greatly influenced by reaction temperature, LHSV, and catalyst function. Naphtha transformation (hyroisomerization, cracking and aromatization) increases with decreasing LHSV and increasing temperature except hydroisomerization activity increases with increasing of temperature till 300°C then began to decrease due to the formation of hydrocracking reaction. The investigation of Pt containing catalysts under study shows a very high hydrogenlysis activity , due to presence of metal component (i.e. Zr, W) which enhances the rate of paraffin isomerization and cracking.The hyroisomerization and the hydrocraking activities can be arranged as follows,. Pt/Zr/W/HY > Pt/HY > Pt/γ-Al2O3 The results showed that, Pt/γ-Al2O3 has higher activity for the direct dehydrogenation of C6 and C7 paraffin's present in naphtha to aromatics than Pt/HY and Pt/Zr/W/HY. This was due to pore volume catalyst ,the aromatics compounds increased as the pore volume increased

Publication Date
Sat Jul 01 2017
Journal Name
Fuel
High purity FAU-type zeolite catalysts from shale rock for biodiesel production
...Show More Authors

View Publication
Scopus (65)
Crossref (66)
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2008
Journal Name
Baghdad Science Journal
Study the Effect of thickness on the Optical Properties Performance of active polymeric laser media
...Show More Authors

The paper include study the effect thickness of the polymeric sample which is manufactured by thermo press way. The sample was used as an active tunable R6G laser media. The remarks show that, when the thickness of the samples is increased, with the same concentration, the spectrum will shift towards the short wavelength, & the quantum fluorescence yield will increased. The best result we obtained for the quantum fluorescence yield is (0.68) at the sample, with thickness (0.304mm) in Ethanol solvent, while when we used the Pure Water as a solvent, we found that the best quantum fluorescence yield is (0.63) at (0.18mm) thickness of the sample.

View Publication Preview PDF
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Study the Effect of solvent on the Optical Properties Performance of active polymeric laser media
...Show More Authors

The paper include studies the effect of solvent of dye doped in polymeric laser sample which manufactured in primo press way, which is used as an active (R6G) tunable dye lasers. The remarks show that, when the viscosity of the solvent (from Pure Water to Ethanol), for the same concentration and thickness of the performance polymeric sample is increased, the absorption spectrum is shifts towards the long wave length (red shift), & towards short wave length (blue shift) for fluorescence spectrum, also increased the quantum fluorescence yield. The best result we obtained for the quantum fluorescence yield is (0.882) with thickness (0.25mm) in Ethanol solvent in concentration (2*10-3mole/liter), while when we used the Pure Water as a solvent,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Iraqi Journal Of Physics
Effect of Deposit Au thin Layer Between Layers of Perovskite Solar Cell on Cell's Performance
...Show More Authors

The present work aims to fabricate n-i-p forward perovskite solar cell (PSC) withئ structure (FTO/ compact TiO2/ compact TiO2/ MAPbI3 Perovskite/ hole transport layer/ Au). P3HT, CuI and Spiro-OMeTAD were used as hole transport layers. A nano film of 25 nm gold layer was deposited once between the electron transport layer and the perovskite layer, then between the hole transport layer and the perovskite layer. The performance of the forward-perovskite solar cell was studied. Also, the role of each electron transport layer and the hole transport layer in the perovskite solar cell was presented. The structural, morphological and electrical properties were studied with X-ray diffractometer, field emission s

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Feb 24 2025
Journal Name
Journal Of Physical Education
Analytical study of Spiking and Its relation With Tactical Performance of Blockers in Iraqi Volleyball Primer League (2020 – 2021)
...Show More Authors

View Publication
Publication Date
Sat Jan 01 2022
Journal Name
Geotechnical Engineering And Sustainable Construction
Stability and Seismic Performance of Tall Steel Structures with Hybrid Energy Absorbers Including P-Delta Effect
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Fri Jul 01 2022
Journal Name
Advanced Powder Technology
Modification of FAU zeolite as an active heterogeneous catalyst for biodiesel production and theoretical considerations for kinetic modeling
...Show More Authors

View Publication
Scopus (25)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Thu Mar 12 2020
Journal Name
Al-khwarizmi Engineering Journal
Optimization the Effect of Electrode Material Change on EDM Process Performance Using Taguchi Method
...Show More Authors

Electrical Discharge Machining (EDM) is a widespread Nontraditional Machining (NTM) processes for manufacturing of a complicated geometry or very hard metals parts that are difficult to machine by traditional machining operations. Electrical discharge machining is a material removal (MR) process characterized by using electrical discharge erosion. This paper discusses the optimal parameters of EDM on high-speed steel (HSS) AISI M2 as a workpiece using copper and brass as an electrode. The input parameters used for experimental work are current (10, 24 and 42 A), pulse on time (100, 150 and 200 µs), and pulse off time (4, 12 and 25 µs) that have effect on the material removal rate (MRR), electrode wear rate (EWR) and wear ratio (WR). A

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Engineering
Roughness Effect on Thermo-Elasto-Hydrodynamic Performance of a 170ᵒ -Arc Partial Journal Bearing
...Show More Authors

In the current analysis, the effects of circumferential scratches along the inner surface of a 170ᵒ -arc partial journal bearing has been numerically investigated. Their impact on the thermo-elasto-hydrodynamic performance characteristics, including maximum pressure, temperature, deformation, and stress, has been examined thoroughly. The ANSYS Fluent CFD commercial code was employed to tackle the iterative solution of flow and heat transfer patterns in the fluid film domain. They are then applied to the ANSYS Static Structure solver to compute the deformation and stress resulted in the solid bearing zone. A wide range of operating conditions has been considered, including the eccentricity ratio ( ) and scratch depth (

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Thu Aug 15 2019
Journal Name
Selcuk Journal Of Agriculture And Food Sciences
The Effect of Knife Clearance on the Machine Performance in Disc Type Silage Machines
...Show More Authors

In this study, active knife and fixed knife of single-row disc silage machine has three different clearance C1, C2 and C3 (1, 3 and 5 mm) and it is tried in three different working speed V1, V2 and V3 (1.8, 2.5 and 3.7 km / h) and PTO speed (540 min-1) and machine's fuel consumption (l/h), average power consumption (kW), field energy consumption (kW/da), product energy consumption (kW/t), field working capacity (da/h), product working capacity (t/h) and Chopping size distribution characteristics of the fragmented material were determined. It has been found that knife-counter knife clearances smaller than 3 mm (1 mm) and larger (5 mm) have a negative effect on machine performance in general. In terms of fuel and power consumptions, the m

... Show More
View Publication Preview PDF
Crossref