Amaranthus viridis L. belongs to the Amaranthaceae family. It is a rich source of numerous phytochemicals and amino acids. The objective of this work was to optimize Ultrasound-Assisted Extraction (UAE) based on the extraction yield and Thin-Layer Chromatography (TLC) profile under different conditions, to compare the optimized UAE to the Soxhlet extraction method and evaluate the cytotoxic effects of the ethyl acetate fraction of the 80 % ethanolic extract on the SKGT-4 (human esophageal adenocarcinoma), AGS (human gastric adenocarcinoma) and A431 (human epidermoid carcinoma). A one-factor at a time experiment was carefully designed to assess the influence of the following factors on the extraction: time, frequency, solid-to-solvent ratio and aqueous ethanol concentration. Soxhlet extraction using 80 % aqueous ethanol was done for defatted plant material, then fractionation using chloroform, ethyl acetate and n-butanol. Cytotoxicity of ethyl acetate fraction was evaluated using the MTT assay on AGS, A431 and SKGT-4 cell lines. The results indicated that in the UAE, the solid-to-solvent ratio has the most significant effect on yield. Soxhlet extraction proved to be more efficient than UAE in terms of TLC profiles. The cytotoxicity of the ethyl acetate fraction exhibited cytotoxic activity against the tested cell lines in a concentration-dependent manner. Thus, selecting a particular extraction method depends on the target compounds. Soxhlet is preferred for gaining certain compounds that require heat for their extraction. The ethyl acetate fraction showed a cytotoxic effect on various cell lines related to cell components and their interactions with phytochemicals present in this fraction.
Autorías: Muayad Kadhim Raheem, Lina Fouad Jawad. Localización: Opción: Revista de Ciencias Humanas y Sociales. Nº. 21, 2019. Artículo de Revista en Dialnet.
Background: The vasoconstricting agents: nor-adrenaline and 5- hydroxytryptamine
(5-HT) have a stimulant action on smooth muscle contractility of the rat vas deferens.
Objective: This study aimed to investigate the effect of exposure to continuous
darkness and continuous light on the contractility of the vasa deferntia smooth
muscles from rats to applied nor-adrenaline and 5-HT.
Method: Male albino wistar rats were divided into 3 experimental groups. Group 1:
Control animals, were exposed to the ordinary photoperiod each day. Group 2: Rats
were kept in a dark room. Group 3: In a room under a bright artificial light.
All animals were killed after 4 weeks.
Results: Vasa deferentia preparations from continuous dar
A simple, rapid and sensitive spectrophotometric method has been developed for the determination of captopril in aqueous solution. The method is based on reaction of captopril with 2,3-dichloro 1,4- naphthoquinon(Dichlone) in neutral medium to form a stable yellow colored product which shows maximum absorption at 347 nm with molar absorptivity of 5.6 ×103 L.mole-1. cm-1. The proposed method is applied successfully for determination of captopril in commercial pharmaceutical tablets.
A sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.
A UV-Vis spectrophotometry method was developed for the determination of metoclopramide hydrochloride in pure and several pharmaceutical preparations, such as Permosan tablets, Meclodin syrups, and Plasil ampoules. The method is based on the diazotization reaction of metoclopramide hydrochloride with sodium nitrate and hydrochloric acid to yield the diazonium salt, which is then reacted with 3,5-dimethyl phenol in the presence of sodium hydroxide to form a yellow azo dye. Calibration curves were linear in the range from 0.3 to 6.5 µg/mL, with a correlation coefficient of 0.9993. The limits of detection and quantification were determined and found to be 0.18 and 0.61 µg/mL, respectively. Accuracy and precision were also determined b
... Show MoreThere are many problems facing the economic entities as a result of its mass production &variation of its products , the matter which had increased the need & importance of cost accounting which is regarded a main tool for the managerial control.
The actual costing system is unable to meet the contemporary management needs ,so the Standard costing system appear to provide the management with required information to perform its functions by the best use& way.
This research aims to determine the standard cost for the direct material for oil extraction activity by applying it in the north oil company.
In current research Copper was employed for preparing a ternary system of Al–Si alloy in different (0.2–2.5 wt. %) the best was taken is (1.5%wt) of copper that circumstances of solidification for improving the mechanical performance of the available in aluminium alloy. Cast iron molds were prepared to obtain tensile strength testing specimens. Alloys were prepared by employing gas furnaces. The molten metal was poured into a preheated cast-iron mold. The obtained alloy structures were studied using an X-ray diffractometer and optical microscopy. The mechanical performance of the prepared alloys was examined under the influence of different hardening conditions in both heat and non-heat-treated conditions. The outcomes showed at the
... Show MoreA new optoelectronic flow injection method is proposed for the determination of ferrous ions (Fe 2+ ) based on thiocyanate complexation to form a deep-red FeSCN 2+ complex.