Preferred Language
Articles
/
kBYuCIcBVTCNdQwCpDC3
Behavior of High Strength Hybrid Reinforcement Concrete Beams
...Show More Authors

Six proposed simply supported high strength-steel fiber reinforced concrete (HS-SFRC) beams reinforced with FRP (fiber reinforced polymer) rebars were numerically tested by finite element method using ABAQUS software to investigate their behavior under the flexural failure. The beams were divided into two groups depending on their cross sectional shape. Group A consisted of four trapezoidal beams with dimensions of (height 200 mm, top width 250 mm, and bottom width 125 mm), while group B consisted of two rectangular beams with dimensions of (125 ×200) mm. All specimens have same total length of 1500 mm, and they were also considered to be made of same high strength concrete designed material with 1% volume fraction of steel fiber. Different types and ratios of FRP rebar were used to reinforce these test beams. The study’s principle variables were the amount and type of flexural reinforcement (glass FRP and basalt FRP) and beam cross-sectional shape (rectangular and trapezoidal). The load-deflection behavior and ultimate load capacity of the beams were studied and compared with one another under flexural test with symmetrical two-point loading. The results show that increasing the reinforcement ratio resulted in higher post cracking flexural stiffness, and higher residual strength, as well as caused an increase in the first cracking load and ultimate load capacity ranged from 3 to 16.9%, and 4.6 to 7.3% respectively. When the GFRP rebars replaced by BFRP, the overall beams flexural performance showed outstanding improvements. Moreover the results indicate that increasing the top width of the beam cross section led to a significant enhancement in the first crack load ranged from 16 to 32.4%, also a remarkable increases in the ultimate load capacity in the range of 35.5 to 35.8% were indicated in the trapezoidal beams compared to rectangular beams. However the results show that the deflections were similar and were approximately 1.07–1.54 mm for all test beams. It is worth noting that the general flexural behavior of all the test beams indicated a ductile behavior with a gradual reduction in strength and high residual strength pre to failure due to proposing steel fiber presence.

Scopus Clarivate Crossref
View Publication
Publication Date
Sat Jul 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Effect of High Salt Concentrations on some Growth Characteristics and Feed Intake Rate of Ctenopharyngodon idella
...Show More Authors
Abstract<p>Grass carp at a weight of 34.68 + 2 g were gradually exposed to four saline concentrations: tap water (0.1), 3, 6, 9, and 12 gm/litter, and the first concentration represented a control treatment. Fish were fed on a diet with a protein content of 30% for ten weeks. Results of the growth experiment showed that the feed conversion rate was 2.46, 3.58, 4.84, 6.77, and -8.56 in the first to fifth treatments, respectively, and the rate feed conversion efficiency was 40.65, 27. 93, 20.66, 14.77 and 11.68 %, while the protein intake was 22.38, 20.44, 18.86, 17.47 and 16.56 g in salt concentrations of 0.1, 3, 6, 9 and 12 g/L, respectively. In another experiment to study the effect of salt acc</p> ... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Effect of Fire Flame (High Temperature) on the Behaviour of Axially loaded Reinforced SCC Short Columns
...Show More Authors

Experimental research was carried out to investigate the effect of fire flame (high temperature) on specimens of short columns manufactured using SCC (Self compacted concrete). To simulate the real practical fire disasters, the specimens were exposed to high
temperature flame, using furnace manufactured for this purpose. The column specimens were cooled in two ways. In the first the specimens were left in the air and suddenly cooled using water, after that the specimens were loaded to study the effect of degree of
temperature, steel reinforcement ratio and cooling rate, on the load carrying capacity of the reinforced concrete column specimens. The results will be compared with behaviour of columns without burning (control specime

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Aug 06 2025
Journal Name
Innovative Infrastructure Solutions
Understanding the effectiveness of elastomeric and plastomeric polymers on the high-temperature performance of asphalt binders
...Show More Authors

The global rise in temperature and the desert climatic conditions prevalent in Middle Eastern countries have exacerbated rutting distress in heavily trafficked highways. Conventional asphalt binders with a high-temperature performance grade (PG 70) have proven inadequate under such extreme conditions, necessitating the development of modified binders with enhanced high-temperature performance. While polymer modification using styrene-butadiene-styrene (SBS), an elastomeric polymer, and ethylene-vinyl acetate (EVA), a plastomeric polymer, has been widely studied, limited research provides a direct comparison of their effectiveness at both the binder and mixture levels under extremely high-temperature conditions. This study addresses this gap

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Periodontal &amp; Implant Science
Bio-hybrid dental implants prepared using stem cells with β-TCP-coated titanium and zirconia
...Show More Authors

Purpose This study investigated periodontal ligament (PDL) restoration in osseointegrated implants using stem cells. Methods Commercial pure titanium and zirconium oxide (zirconia) were coated with beta-tricalcium phosphate (β-TCP) using a long-pulse Nd:YAG laser (1,064 nm). Isolated bone marrow mesenchymal cells (BMMSCs) from rabbit tibia and femur, isolated PDL stem cells (PDLSCs) from the lower right incisor, and co-cultured BMMSCs and PDLSCs were tested for periostin markers using an immunofluorescent assay. Implants with 3D-engineered tissue were implanted into the lower right central incisors after extraction from rabbits. Forty implants (Ti or zirconia) were subdivided according to the duration of implantation (healing period: 45 o

... Show More
View Publication
Crossref (5)
Crossref
Publication Date
Sun Aug 07 2022
Journal Name
Nanomaterials
Efficient Heat Transfer Augmentation in Channels with Semicircle Ribs and Hybrid Al2O3-Cu/Water Nanofluids
...Show More Authors

Global technological advancements drive daily energy consumption, generating additional carbon-induced climate challenges. Modifying process parameters, optimizing design, and employing high-performance working fluids are among the techniques offered by researchers for improving the thermal efficiency of heating and cooling systems. This study investigates the heat transfer enhancement of hybrid “Al2O3-Cu/water” nanofluids flowing in a two-dimensional channel with semicircle ribs. The novelty of this research is in employing semicircle ribs combined with hybrid nanofluids in turbulent flow regimes. A computer modeling approach using a finite volume approach with k-ω shear stress transport turbulence model was used in these simu

... Show More
View Publication
Scopus (12)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2017
Journal Name
International Journal Of Advanced Computer Science And Applications
Fast Hybrid String Matching Algorithm based on the Quick-Skip and Tuned Boyer-Moore Algorithms
...Show More Authors

View Publication
Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Biomaterials Science
Single-atom silver-borophene hybrid hydrogels for electrically stimulated wound healing: a multifunctional antibacterial platform
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Fri Sep 08 2006
Journal Name
Journal Of Engineering
INFLUENCE OF DEFECT IN THE CONCRETE PILES USING NON-DESTRUCTIVE TESTING
...Show More Authors

This paper presents the results of experimental investigation carried out on concrete model piles to study the behaviour of defective piles. This was achieved by employing non-destructive tests using ultrasonic waves. It was found that the reduction in pile stiffness factor is found to be about (26%) when the defect ratio increased from (5%) to (15%). The modulus of elasticity reduction factor as well as the dynamic modulus of elasticity reduction factor increase with the defect ratio

Publication Date
Wed Sep 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Improving the Properties of Asphalt Concrete Mixtures Using Iron Filling Wastes
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Journal Of Engineering
Evaluating Asphalt Concrete Properties by the Implementation of Ultrasonic Pulse Velocity
...Show More Authors

 

In past years, structural pavement solution has been combined with destructive testing; these destructive methods are being replaced by non-destructive testing methods (NDT). Because the destructive test causes damage due to coring conducted for testing and also the difficulty of adequately repairing the core position in the field. Ultrasonic pulse velocity was used to evaluate the strength and volumetric properties of asphalt concrete, of binder course. The impact of moisture damage and testing temperature on pulse velocity has also been studied. Data were analyzed and modeled. It was found that using non-destructive testing represented by pulse velocity could be useful to predict the quality of asphalt c

... Show More
View Publication Preview PDF
Crossref (4)
Crossref