Background: Titanium implant is widely used in dentistry because of its extraordinary biocompatibility and mechanical properties. To increase bone–implant connection and provide early loading after placement, implant is stored in different storage medium and treated with UV light. Both of them are applicable methods to increase the bioactivity of titanium and overcome the biological aging. This study was designed to assess the effect of vacuum storage method and air storage with and without UV light treated of Cp Ti implant mechanically and histologically. Materials and methods: Titanium screws were acid etched and prepared in four different modes using different storage methods (air or vacuum and, with or without UV treatment. The implant screws were stored 4 weeks and then implanted into rabbit's tibia for histological and torque removal examinations. Results: There was a significant increase in mean value of torque removal test for screws air treated with UV light, vacuum and vacuum treated with UV light (14.5 ,13.8 ,17.92 N.cm respectively after 2 weeks, and (21.5333, 22.5 ,26.47 N.cm respectively after 4 weeks) compared with air storage screws (8.4 N.cm after 2 weeks, and 11.4 N.cm after 4 weeks). Histological examination showed bone formation mineralization and maturation increased with advancing time for air treated with UV light, vacuum and vacuum treated with UV light screws. Conclusion: vacuum storage method and air storage with UV light treated methods of Cp Ti implant had great effect in increasing the osseointegration than air storage methods, while the vacuum storage and treated with UV light have synergistic effects on the biological properties of aged titanium surfaces.
Abstract Rasha Hameid Jehad Baghdad University Background: The high reactivity of hydrogen peroxide used in bleaching agents have raised important questions on their potential adverse effects on physical properties of restorative materials. The purpose of this in vitro study was to evaluate the effect of in-office bleaching agents on the microhardness of a new Silorane-based restorative material in comparison to methacrylate-based restorative material. Materials and method: Forty specimens of Filtek™ P90 (3M ESPE,USA) and Filtek™ Supreme XT (3M ESPE, USA) of (8mm diameter and 3m height) were prepared. All specimens were polished with Sof-Lex disks (3M ESPE, USA). All samples were rinsed and stored in incubator 37˚C for 24 ho
... Show Moreto evaluate the effect of various Nd:YAG frequency doubled laser parameters on the acid
dissolution and the progression of in vitro caries like lesions in human enamel.
Materials and Methods: Human extracted caries free upper first premolar teeth were collected for
this study. The irradiated teeth were divided into two groups. The first group was irradiated with
continuous Nd:YAG laser radiation, and the second group was irradiated with chopped Nd:YAG laser
radiation. For the first group, power and exposure time were changed while for the second group
power and number of pulses were changed. The spot diameter was kept constant for all the samples.
Results: using 1.5 W and 3 seconds (exposure time), best results among
The present research was carried out to assess the toxic effect of oral administration of the aqueous extract of Nerium oleander leaves and flowers daily at doses of (25) mg/kg body weight for four weeks in mice. The toxicity of this plant parts was determined after two and four weeks by measuring the parameters of cytogenetic (mitotic index, micronucleus %), and serum levels of the hematological (RBC, Hb, WBC) and biochemical (GOT, GPT, ALT, AST) indexes in comparison with that of the control (normal saline), also clinical signs were determined. The results showed a significant decrease in mitotic index while an obvious raise was seen in micronucleus percentage in comparison with that of the control after the two periods of admini
... Show MoreMyelosuppression is one of the serious adverse effects of cancer chemotherapy that lead to life threatening febrile neutropenia and considered a limiting factor for successful therapy. Cyclophosphamide a widely used anticancer drugs, induces severe bone marrow suppression by damaging hematopoietic stem cells. As cancer incidence expands globally, the demand for an effective myeloprotective therapy during cancer treatment is also increasing.Nigella sativa seed oil, a well-known plant extract that widely used for various health conditions. This study aims to evaluate the myeloprotective activity of Nigella sativa seed oil in cyclophosphamide-induced myelosuppression mice model. Myelosuppression induced by single intraperitoneal injection o
... Show MoreAtopic dermatitis (atopic eczema), is a common familial chronic inflammatory skin disease, determined by xerosis, itching, scaly and erythematous skin lesions, and high serum levels of IgE. Between 10 to 20% of children and 1 to 3% of adults worldwide affected by it and has negative medical and social effect on patients and their families. To evaluate the effectiveness of Phytosterol Fraction of Chenopodium Murale on induced atopic dermatitis (AD) of mice; Forty mice were included in the study, divided in to four groups (10 mice/group): apparently healthy, induced AD without treatment, induced AD treated with Tacrolimus 0.1% ointment, and induced AD treated with Phytosterol Fraction of Chenopodium Murale cream 3% topica
... Show MoreKE Sharquie, AA Noaimi, SA Al-Hashimy, MM Al-Salih, Journal of Cosmetics, Dermatological Sciences and Applications, 2014 - Cited by 12
SnS has been widely used in photoelectric devices due to its special band gap of 1.2-1.5 eV. Here, we reported on the fabrication of SnS nanosheets and the effect of synthesis condition together with heat treatment on its physical properties. The obtained band gap of the SnS nanosheets is in the rage of 1.37-1.41 eV. It was found that the photo-current density of a thin film comprised of SnS nanosheets could be enhanced significantly by annealing treatment. The maximum photo-current density of the stack structure of FTO/SnS/CdS/Pt was high as 389.5 mu A cm(-2), rendering its potential application in high efficiency solar hydrogen production.
Background: Elastomeric chains are one of the most commonly used force delivery systems. They have the ability to exert a continuous force, convenience of use, compatibility to oral environment and cost effectiveness but one of the inherited disadvantages is force degradation. Materials and methods: This in vitro study was designed to evaluate the effect of alcohol presence in mouthwashes on force decay of different configurations of clear elastomeric chains from (Ortho Technology company) which are: closed , short and long under the effect of time at (Initial, 1, 2, 3 and 4 weeks) intervals with exposure to different chemical solutions. A total (540) modules of elastomeric chains of three different types (long, short and closed) trans
... Show MoreBackground: The aim of this in vitro study was to evaluate and compare the effect of preheating microleakage among three different filler size composites which include Filtektm Z250 micro hybrid, Z250xt Nano hybrid and nanocomposite Z350xt. in Class II cavity preparation .
Materials and methods: sixty maxillary first premolars were prepared with class II cavities. Samples were divided into three groups according to material used group A (FiltekZ250 micro hybrid). Group B(Z250xt Nano hybrid). Group C (nanocomposite Z350xt)and each group divided into two subgroups of ten teeth according to temperature of composite:
... Show MoreObjectives To assess the feasibility and accuracy of a new prototype robotic implant system for the placement of zygomatic implants in edentulous maxillary models. Methods The study was carried out on eight plastic models. Cone beam computed tomographs were captured for each model to plan the positions of zygomatic implants. The hand-eye calibration technique was used to register the dynamic navigation system to the robotic spaces. A total of 16 zygomatic implants were placed, equally distributed between the anterior and the posterior parts of the zygoma. The placement of the implants (ZYGAN®, Southern Implants) was carried out using an active six-jointed robotic arm (UR3e, Universal Robots) guided by the dynamic navigation coordinate tran
... Show More