The research aims to identify small and medium enterprises in accounting thought in terms of definition and concept, and this international financial reporting standard for small and medium-sized enterprises (SMEs) in the theoretical aspect. As for the practical aspect, the small and medium-sized enterprises standard has been applied to the financial statements of the company in question, the preparation of the opening entry on the date of the transition, the requirements of measurement and the accounting disclosure on the date following the application of the standard, and the preparation of the company's financial statements and the accompanying explanations according to the standard of small and medium-sized enterprises. The research reached a set of conclusions, the most prominent of which is. The emergence of fundamental differences between the applications of the small and medium-sized enterprises standard on the one hand and the applications of the unified accounting system on the other hand, and this is what appears in the table of the impact of adopting the International Financial Reporting Standard for Small and Medium Enterprises before and after implementation. Simplifying the accounting measurement and disclosure requirements within the SMEs standard enables Iraqi companies to apply it and thus prepare globally comparable financial statements, which increases the chances of foreign companies entering to invest in Iraq. The research recommended the necessity of developing an effective system for the transition to the international financial reporting standard for small and medium-sized enterprises and removing the obstacles that face small and medium enterprises when implementing it.
In the present study, the effectiveness of a procedure of electrocoagulation for removing chemical oxygen demand (COD) from the wastewater of petroleum refinery has been evaluated. Aluminum and stainless steel electrodes were used as a sacrificial anode and cathode respectively. The effect of current density (4-20mAcm−2), pH (3-11), and NaCl concentration (0-4g/l) on efficiency of removal of chemical oxygen demand was investigated. The results have shown that increasing of current density led to increase the efficiency of COD removal while increasing NaCl concentration resulted in decreasing of COD removal efficiency. Effect of pH was found to be lowering COD re
Objective(s): This study aimed to evaluate job satisfaction among nurses working at primary health care centers in Samawa City.
Methodology: A Descriptive evolutional study has been carried out during the period from 1 February 2022 to 1 June 2022. A nonprobability (convenience) sample of (200) nurse were selected from different educational level. A questionnaire format is developed for the purpose of fulfilling the objectives of the study. Content validity of the questionnaire and reliability has been determined. Data are analyzed using IBM SPSS version 19 software (2010).
Results: The findings indicate that 52% of nurses are showing high level of job satisfa
... Show MoreFiber Reinforced Polymer (FRP) bars are anisotropic in nature and have high tensile strength in the fiber direction. The use of High-Strength Concrete (HSC) allows for better use of the high-strength properties of FRP bars. The mechanical properties of FRP bars can yield to large crack widths and deflections. As a result, the design of concrete elements reinforced with FRP materials is often governed by the Serviceability Limit States (SLS). This study investigates the short-term serviceability behavior of FRP RC I-beams. Eight RC I-beams reinforced with carbon-FRP (CFRP) and four steel RC I-beams, for comparison purposes, were tested under two-point loading.
Deformations on the concrete and crack widths and spacing are measured and
Background: The incidence of maternal mortality in
placenta previa accrete is 7%,and its preoperative
diagnosis is of a great value.
Objective: to evaluate the efficacy of transabdominal
color Doppler ultrasound in diagnosing placenta
previa accreta and inccreta. Color Doppler imaging
criteria used in: includes diffuse parenchymal
placental lacunar flow, focal intra parenchymal
placental lacunar flow and bladder uterine serosa
interphase hyper-vascularity.
Design: Prospective study on patients from
January2007 to January 2008.
Patients and method: 48patients with one caesarean
section or more and with persistent anterior placenta
previa diagnosed by transabdominal ultrasound were
examined by c