The research dealt with the design of the cost accounting system for the transport service and its Role in improving the efficiency of pricing decisions through the application of the cost system based on ABC activities. The main activities were defined and cost guides were to measure the cost of each service and to determine the cost of each service for the purpose of providing management with appropriate information and pricing decisions The problem of research in the lack of adoption by some public companies in the service sector on the cost accounting system to calculate the cost of service as well as the lack of identification of productive activities and service activities and therefore cannot make the appropriate decision to the pricing of its services fairly and rationally. The aim of the research is to design a system of cost accounting based on ABC activities in the service sector to calculate the cost of service for the purpose of providing appropriate information to the administration for the purpose of increasing the effectiveness of pricing decisions for those services. The main findings of the research that the use of cost accounting system helps to identify and measure the cost of transport services correctly and thus the possibility the administration should make a rational and rational decision to price services more fairly and objectively.
In this study, a three-dimensional finite element analysis using ANSYS 12.1 program had been employed to simulate simply supported reinforced concrete (RC) T-beams with multiple web circular openings subjected to an impact loading. Three design parameters were considered, including size, location and number of the web openings. Twelve models of simply supported RC T-beams were subjected to one point of transient (impact) loading at mid span. Beams were simulated and analysis results were obtained in terms of mid span deflection-time histories and compared with the results of the solid reference one. The maximum mid span deflection is an important index for evaluating damage levels of the RC beams subjected to impact loading. Three experi
... Show MoreIn this study, an experimental investigation had conducted for six high strength laced reinforced concrete one-way slabs to discover the behavior of laced structural members after being exposed to fire flame (high temperature). Self-compacted concrete (SCC) had used to achieve easy casting and high strength concrete. All the adopted specimens were identical in their compressive strength of ( , geometric layout 2000 750 150 mm and reinforcement specifics except those of lacing steel content, three ratios of laced steel reinforcement of (0.0021, 0.0040 and 0.0060) were adopted. Three specimens were fired with a steady state temperature of for two hours duration and then after the specimens were cooled suddenly by spraying water. The
... Show MoreObjective(s): To determine the impact of instructional intervention program upon psychological health status for
women who undergo chemotherapy after mastectomy
Methodology: The sample consisted of (100) women, (50) considered as study group, and another (50) the control
group. A pre test was done for both groups (study and control), and then the study samples were exposed to an
instructional intervention and three-dimensional post tests and the length of time between each test 21 days in
the Institute and Hospital of Radiation and Nuclear Medicine. The questionnaire composed of three parts, first,
demographic information; include (age, educational level, type of family, occupation, marital status, and adequacy
of mo
In this work, enhancement to the fluorescence characteristics of laser dye solutions hosting highly-pure titanium dioxide nanoparticles as random gain media. This was achieved by coating two opposite sides of the cells containing these media with nanostructured thin films of highly-pure titanium dioxide. Two laser dyes; Rhodamine B and Coumarin 102, were used to prepare solutions in hexanol and methanol, respectively, as hosts for the nanoparticles. The nanoparticles and thin films were prepared by dc reactive magnetron sputtering technique. The enhancement was observed by the narrowing of fluorescence linewidth as well as by increasing the fluorescence intensity. These parameters were compared to those of the dye only and the dye solution
... Show MoreIn this study, the effect of fire flame on the punching shear strength of steel fiber reinforced concrete flat plates was experimentally investigated using nine half-scale specimens with dimensions of 1500×1500 mm and a total thickness of 100 mm. The main investigated variables comprised the steel fiber volume fraction 0, 1, and 1.5% and the burning steady state temperature 500 and 600 °C. The specimens were divided into three groups, each group consists of three specimens. The specimens in the first group were tested with no fire effect to be the reference specimens, while the others of the second and third groups were tested after being exposed to fire-flame effect. The adopted characteristics of the fire test were; (one hour) b
... Show MoreThe current study includes (130) T2DM patients (group P) [51 males and 79 females with an ages range (35 to 55) and ages mean 49.89 years], they are sub-grouped into three categories according to their HbA1c value. patients with HbA1c less than 7 are considered as good controlled diabetic patients (30 patients) (group P1), while patients with HbA1c between 7 and 8 are considered as medium controlled diabetic patients (40 patients) (group P2), and the patient whom their HbA1c more than 8 are considered as uncontrolled diabetic patients (50 patients) (group P3). The patients group results are compared to control healthy subjects (35 subjects) (group C) [14 males and 21 Females with age range 45.51 years] matched for age, gender and BMI wer
... Show MoreThis study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the p
... Show MoreThe objective of this work is to investigate the performance of a conventional three phase induction motor supplied by unbalanced voltages. An effort to study the motor steady state performance under this disturbance is introduced. Using per phase equivalent circuit analysis with the concept of symmetrical components approach, the steady state performance is theoretically calculated. Also, a model for the induction motor with the MATLAB/Simulink SPS tools has been implemented and steady state results were obtained. Both results are compared and show good correlation as well. The simulation model is introduced to support and enhance electrical engineers with a complete understanding for the steady state performance of a fully loaded induc
... Show MoreThis paper presents the non-linear finite element method to study the behavior of four reinforced rectangular concrete MD beams with web circular openings tested under two-point load. The numerical finite elements methods have been used in a much more practical way to achieve approximate solutions for more complex problems. The ABAQUS /CAE is chosen to explore the behavior of MD beams. This paper also studies, the effect of both size and shape of the circular apertures of MD beams. The strengthening technique that used in this paper is externally strengthening using CFRP around the opening in the MD beams. The numerical results were compared to the experimental results in terms of ultimate load failure and displace
... Show More