Abstract [email protected] Background: Acute Traumatic Stress Disorder (ATSD) might be complicated by Post Traumatic Stress Disorder (PTSD). Psychological First Aid (PFA) said to be helpful to reduce the possibility of reduction of ASD and PTSD symptoms. PFA is simple procedure to deliver help & support to victims, may be by some one close to him, quietly and professionally. Iraq has and is still experiencing, continuous traumatic stresses. ATSD is especially seen in war such as during the Gulf War, Embargo and nowadays under the current American occupation. With the extreme shortage of recourses and the given late priority to psychological problems and intervention have disastrous consequences on the psycho-social wellbeing of people. Aims: To construct: 1. ATSD Scale (ATSDS) and 2. PFA Program (PFAP) to be used by careers. Using the null hypothesis, it was expected that there will not be significant reduction in ATSD symptoms after the implementation of PFAP. Methods: ATSD Scale was constructed using a 256 population from of both sexes with an age range 15-54 years. Diagnosis based upon DSM-IV criteria for ATSD classification. 10 female patients (23-54) year were treated individually by debriefing as part of the PFAP. Suitable and randomly referred patients were treated over; 12 biweekly sessions, for 45 minutes each session for the period from June 2003- September 03. Outcome: Both ATSD and ATSDP proved to be valid and reliable. Using Will- Coxon’s Rank Signal Test; PFAP for ATSD was effective in reducing the ATSD symptoms significantly. This result was compatible with the literature. Further studies are recommended to use; larger samples and a follow up period, as well as application of PFAP in group setting might prove to be more cost effective in massive traumatic crises and casualties like war. Keys: Acute, Aid, Debriefing, Disorder, First, Iraq, Post, Psychological, Stress, Traumatic, Treatment, War.
The radon gas concentration in environmental samples soil and water of selected regions in Al-Najaf governorate was measured by using alpha-emitters registrations which are emitted form radon gas in (CR-39) nuclear track detector. The first part is concerned with the determination of radon gas concentration in soil samples, results of measurements indicate that the highest average radon concentration in soil samples was found in (Al-Moalmen) region which was (100.0±7.0 Bq/m3), while the lowest average radon concentration was found in (Al-Askary) region which was (38.5±4.7 Bq/m3), with an average value of (64.23±14.9 Bq/m3) ,the results show that the radon gas concentrations in soil is below the allowed limit from (ICRP) agency which is (
... Show MoreThis study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From
... Show MoreIn the present study, magnet silica-coated Ag2WO4/Ag2S nanocomposites (FOSOAWAS) were fabricated via a multistep method to address the drawbacks related to single photocatalysts (pure Ag2WO4 and pure Ag2S) and to clarify the significant influence of semiconductor heterojunction on the enhancement of visible-light-driven organic degradation. Different techniques were performed to investigate the elemental composition, morphology, magnetic and photoelectrochemical properties of the fabricated FOSOAWAS photocatalyst. The FOSOAWAS photocatalyst (1 g/L) exhibited excellent photodegradation efficiency (99.5%) against Congo red dye (CR = 20 ppm) after 140 min of visible-light illumination. This result confirmed the ability of the heterojunction be
... Show MoreAromaticity, antiaromaticity and chemical bonding in the ground (S0), first singlet excited (S1) and lowest triplet (T1) electronic states of disulfur dinitride, S2N2, were investigated by analysing the isotropic magnetic shielding, σiso(r), in the space surrounding the molecule for each electronic state. The σiso(r) values were calculated by state-optimized CASSCF/cc-pVTZ wave functions with 22 electrons in 16 orbitals constructed from gauge-including atomic orbitals (GIAOs). The S1 and T1 electronic states were confirmed as 11Au and 13B3u, respectively, through linear response CC3/aug-cc-pVTZ calculations of the vertical excitation energies for eight singlet (S1–S8) and eight triplet (T1–T8) electronic states. The aromaticities of S
... Show MorePurpose Heavy metals are toxic pollutants released into the environment as a result of different industrial activities. Biosorption of heavy metals from aqueous solutions is a new technology for the treatment of industrial wastewater. The aim of the present research is to highlight the basic biosorption theory to heavy metal removal. Materials and methods Heterogeneous cultures mostly dried anaerobic bacteria, yeast (fungi), and protozoa were used as low-cost material to remove metallic cations Pb(II), Cr(III), and Cd(II) from synthetic wastewater. Competitive biosorption of these metals was studied. Results The main biosorption mechanisms were complexation and physical adsorption onto natural active functional groups. It is observed that
... Show MoreThis study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From
... Show More