Preferred Language
Articles
/
jperc-121
Slums and its implication on security in Baghdad
...Show More Authors

The research team seeks to study the phenomena of random housing in Iraqi society in general and Baghdad city in particular by standing on the causes behind this phenomena and its relation with security situation in Baghdad. The researchers adopted a theoretical and practical framework. The main objective is to diagnose the risks caused by the escalation of slums in Baghdad city. 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Apr 16 2021
Journal Name
Turkish Journal Of Computer And Mathematics Education
Awareness of the concepts of the green economy among the student-teacher at the College of Education for Pure Sciences - Ibn al-Haytham in Iraq
...Show More Authors

Preview PDF
Publication Date
Wed Nov 16 2022
Journal Name
Res Militaris
The contents of the campaign (your health is a trust) of the World Health Organization in Iraq to prevent infection with the Covid 19 virus
...Show More Authors

This study examines the analysis of the contents of the international public relations campaign in confronting the Covid-19 virus, which was taken from the (Your Health is a Trust) campaign for the World Health Organization, Iraq office.The research problem revolves around a main question that is, what are the axes of the campaign (Your Health is a Trust) established by the World Health Organization (Iraq office) in the prevention of Covid 19 virus?From this main question, several sub-questions emerged that this study answered on their Facebook page, and the communication activities of the Covid-19 awareness campaign. In the content analysis form, as this form included a number of main themes and main categoriesthat were adopted in analyzin

... Show More
View Publication Preview PDF
Scopus
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
New Approach for The Turbidimetric Determination of Iron(III) in Drug Samples of Different Origins Using Homemade Linear Array Ayah 5SX1-T-1D-CFI Analyser
...Show More Authors

A new Turbidimetric method characterized by simplicity, accuracy and speed for determination of iron(III) in drug samples by continuous flow injection analysis. The method was based on the formation of complex for iron(III) with 8-hydroxyquinoline in presence of ammonium acetate as a medium for the formation of deep green precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.6 mL.min-1 flow rate using H2O as a carrier, 1.9 mL.min-1 (14 mmol.L-1) ammonium acetate, 2.4 mL.min-1 (14 mmol.L-1) 8-hydroxyquinoline, 60 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.1-8.0 mmol.L-1

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 16 2022
Journal Name
Res Militaris
Public Relations Employment of Foreign Oil Corporate Social Responsibility Programs Operating in Iraq Analytical Study of Programs from 1/1/2013 to 31/12/2021
...Show More Authors

This research addresses the employment of public relations for foreign oil corporate social responsibility programs operating in Iraq. It is a study of the programmes of six petroleum companies operating in Basra Governorate, which were selected for research as the highest production of Iraqi oil, as well as its enjoyment of strategic oil stores in Iraq.It contains the largest oil fields operatedby major international companies. This study aims at a number of objectives, notably the following:1)Recognize the most prominent corporate social responsibility projects and initiatives the companies have introduced to the local public.2)Investigate the extent to which the Iraqi publ

... Show More
View Publication
Scopus
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Turbidimetric Determination of Metoclopramide Hydrochloride in Pharmaceutical Preparation via the Use of A new Homemade Ayah 6SX1-T-2D Solar Cell-Continuous Flow Injection Analyser
...Show More Authors

A newly developed analytical method characterized by its speed and sensitivity for the determination of metoclopramide hydrochloride (MCP-HCl) in pure and pharmaceutical preparation via turbidimetric measurement (0-180o) by Ayah 6SX1-T-2D Solar cell-CFI Analyser. The method was based on the reaction of phosphomolybdic acid with metoclopramide hydrochloride in acidic medium to form yellowish white precipitate for the ion-pair complex. Turbidity was measured via the reflection of incident light that collides on the surface precipitated particles at 0-180o. Chemical and physical parameters were studied and optimized. The calibration graph was linear in the range of 0.0005-3 or 0.0005- 4 mMol.L-1, with correlation coefficient r = 0.9947&

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Biochem. Cell. Arch.
External morphology study of female genus Hauptidia Dworaowska, 1970 of sub-family typhlocybinae Kirschbaum, 1868, order hemiptera collected from Al-Kafal area in Babylon, Iraq
...Show More Authors

Scopus (1)
Scopus
Publication Date
Mon Jan 20 2025
Journal Name
Sciences Journal Of Physical Education
Individual analysis of kinetic response variables according to the measurement of the H7 system for the best jumping players in the national basketball team 2021
...Show More Authors

View Publication
Publication Date
Fri Nov 24 2023
Journal Name
Iraqi Journal Of Science
New Turbidimetric-Continuous Flow Injection Analysis Method for The Determination of Chlorpromazine HCl in Pharmaceutical Preparation Using Linear Array Ayah 5SX1-T-1D-CFI Analyser
...Show More Authors

A new turbidimetric-flow injection method is described for the determination of chlorpromazine HCl in pure and pharmaceutical preparation. The method is characterized by simplicity, sensitivity and fast, it is based on formation of ion pair compound between chlorpromazine HCl and Potassium hexacyanoferrate(III) in an acid medium for the formation of greenish yellow precipitate. This precipitate was determined using homemade Linear Array Ayah 5SX1-T-1D continuous flow injection analyser. Optimum concentrations of chemical reactants, physical instrumental conditions have been investigated. The linear dynamic range of chlorpromazine HCl was 3-30 mmol.L-1 while correlation coefficient (r) was 0.9929 and percentage linearity (%r2) C.O.D was 9

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Journal University Of Kerbala
Synthesis and Characterization of Some Metal Complexes of [2-chloro-N-(1,5-dimethyl-3-oxo-2-phenyl-2,3-dihydro-1H-pyrazol-4-ylcarbamothioyl)acetamide] (L)
...Show More Authors

A new ligand [ 2-chloro-N- (1,5-dimethyl-3-oxo-2-phenyl-2,3-dihydro -1H-pyrazol- 4-ylcarbamothioyl)acetamide](L) was synthesized by reacting the Chloro acetyl isothiocyanate with 4-aminoantipyrine,The ligand was characterized by(C HNS) elemental microanalysis and the spectral measurements including Uv-Vis ,IR ,1H and13C NMR spectra, some transition metals complex of this ligand were prepared and characterized by Uv-Vis, FT-IR spectra, conductivity measurements, magnetic susceptibility and atomic absorption. From the obtained results the molecular formula of all prepared complexes were [M(L)2(H2O)2]Cl2 (M+2 =Mn, Co, Ni, Cu, Zn, Cd and Hg),the proposed geometrical structure for all complexes were octahedral.

Publication Date
Tue Oct 01 2019
Journal Name
International Journal Of Drug Delivery Technology
Simple and Rapid Method For Estimate of Propranolol With Bi (III) Via Long-Distance Chasing Photometer (NAG-ADF-300-2) Utilization Continuous Flow Injection Analysis
...Show More Authors

A simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the

... Show More