The purpose of this research is to identify the effect of the use of project-based learning in the development of intensive reading skills at middle school students. The experimental design was chosen from one group to suit the nature of the research and its objectives. The research group consisted of 35 students. For the purpose of the research, the following materials and tools were prepared: (List of intensive reading skills, intensive reading skills test, teacher's guide, student book). The results of the study showed that there were statistically significant differences at (0.05) in favor of the post-test performance of intensive reading skills. The statistical analysis also showed that the project-based learning approach has a high effect on the development of intensive reading skills among students in the research group. This was proved by calculating the effect size; using Eta squared (²η), where the effect size was equal to 0.94. In light of the findings of the research, he recommended a set of recommendations, including the need to review the objectives of teaching reading in the middle stage, so that these goals include intensive reading skills. As well as the need to train Arabic teachers in service on how to develop the skills of intensive reading through active learning methods, including the method of the project based on the effectiveness and activity of students.
Prepositions have a key function, which is to associate parts of a sentence, called letters In addition, it adds the meanings of the verbs to the names, ie reached by them, and called by the coffin characters Qualities..
I chose to search for the meaning of the preposition "from" in Surat Maryam to know its meanings in terms of originality and expansion, so the title of the research (the meanings of preposition "from" in terms of originality and expansion in Surat Maryam model(
The goal of this work is to check the presence of PNS (photon number splitting) attack in quantum cryptography system based on BB84 protocol, and to get a maximum secure key length as possible. This was achieved by randomly interleaving decoy states with mean photon numbers of 5.38, 1.588 and 0.48 between the signal states with mean photon numbers of 2.69, 0.794 and 0.24. The average length for a secure key obtained from our system discarding the cases with Eavesdropping was equal to 125 with 20 % decoy states and 82 with 50% decoy states for mean photon number of 0.794 for signal states and 1.588 for decoy states.
Cancer stem cells (CSCs) are defined as a population of cells present in tumours, which can undergo self-renewal and differentiation. Identification and isolation of these CSCs using putative surface markers have been a priority of research in cancer. With this background we selected pancreatic normal and tumor cells for this study and passaged them into animal tissue culture medium. Further staining was done using alkaline phosphatase and heamatoxilin staining. Blue to purple colored zones in undifferentiated pluripotent stem cells and clear coloration in the chromatin material indicated pancreatic cells. Further studies on the cell surface marker CD 44 were done using ELISA. For this, the protein was extracted from cultivated normal and t
... Show MoreThe A2?u-X1?g+ emission band system of 7LiH1 molecule has been calculated for Lambda doubling. The relation between wave number ?p , ?Q , ?R conducted the energies of the state of rotation F (J), and (J + 1) with rotational quantum number J, respectively, of 7LiH1 molecule for statehood A2?u using the rotation, fixed vibrational states of both the ground and raised crossovers vibrational against ???= 0 to V ' = 0-4using rotational levels J = 0 to J = 20 have found.
In this study, the use of non-thermal plasma theory to remove toxic gases emitted from a vehicle was experimentally investigated. A non-thermal plasma reactor was constructed in the form of a cylindrical tube made of Pyrex glass. Two stainless steel rods were placed inside the tube to generate electric discharge and plasma condition, by connecting with a high voltage power supply (up to 40 kV). The reactor was used to remove the contaminants of a 1.25-liter 4-cylinder engine at ambient conditions. Several tests have been carried out for a ranging speed from 750 to 4,500 rpm of the engine and varying voltages from 0 to 32 kV. The gases entering the reactor were examined by a gas analyzer and the gases concentration ratio
... Show MoreResearchers used different methods such as image processing and machine learning techniques in addition to medical instruments such as Placido disc, Keratoscopy, Pentacam;to help diagnosing variety of diseases that affect the eye. Our paper aims to detect one of these diseases that affect the cornea, which is Keratoconus. This is done by using image processing techniques and pattern classification methods. Pentacam is the device that is used to detect the cornea’s health; it provides four maps that can distinguish the changes on the surface of the cornea which can be used for Keratoconus detection. In this study, sixteen features were extracted from the four refractive maps along with five readings from the Pentacam software. The
... Show MoreThis research analyzes the level of the short circuit effect of the Iraqi super network and decides the suitable location for the High Voltage Direct Current (HVDC) connections in order to obtain the best short circuit reduction of the total currents of the buses in the network. The proposed method depends on choosing the transmission lines for Alternating current (AC) system that suffers from high Short Circuit Levels (SCLs) in order to reduce its impact on the transmission system and on the lines adjacent to it and this after replacing the alternating current (AC) line by direct current (DC) line. In this paper, Power System Simulator for Engineering (PSS/E) is used to model two types of HVDC lines in an effective regi
... Show MoreDBN Rashid, INTERNATIONAL JOURNAL OF DEVELOPMENT IN SOCIAL SCIENCE AND HUMANITIES, 2021
In this research, the electrical characteristics of glow discharge plasma were studied. Glow discharge plasma generated in a home-made DC magnetron sputtering system, and a DC-power supply of high voltage as input to the discharge electrodes were both utilized. The distance between two electrodes is 4cm. The gas used to produce plasma is argon gas which flows inside the chamber at a rate of 40 sccm. The influence of work function for different target materials (gold, copper, and silver), - 5cm in diameter and around 1mm thickness - different working pressures, and different applied voltages on electrical characteristics (discharge current, discharge potential, and Paschen’s curve) were studied. The results showed that the discharge cur
... Show More