In light of increasing demand for energy consumption due to life complexity and its requirements, which reflected on architecture in type and size, Environmental challenges have emerged in the need to reduce emissions and power consumption within the construction sector. Which urged designers to improve the environmental performance of buildings by adopting new design approaches, Invest digital technology to facilitate design decision-making, in short time, effort and cost. Which doesn’t stop at the limits of acceptable efficiency, but extends to the level of (the highest performance), which doesn’t provide by traditional approaches that adopted by researchers and local institutions in their studies and architectural practices, limits to assumption of prototypes and their design characteristics to evaluate and select the efficient ones. Without comprehensive coverage to variables range and design possibilities with points of balance between the conflicting influence on performance. Forcing them to shorten, round up and exclude many (values and determinants) to avoid consequent of extra time and effort and the additional costs for performance assessment methods. All due to the cognitive weakness in adopt modern approaches, which become easier for designers to learning and apply. Highlighting (Performance-Based Parametric Design), which achieves this level of performance and avoided all the negative aspects of traditional approaches. Although this approach has been applied in several architecture trends, however, this research will focus on (climate performance and energy consumption). Highlighting a research problem, “lack of cognitive clearness about the nature of adopting parametric approach for performance-based design in order to achieve more efficient designs”. The research will focus on local housing patterns as a simplified model for applying the parametric approach, So the research goal will be “Highlighting and unveiling the nature of the parametric approach and its mechanism in performance-Based Design, to create and optimize design characteristics, towards most efficient designs within the local housing styles”. To achieve this goal was to build a hypothesis “The mechanism of parametric approach Managed to address a conflict influence of design characteristics in building’s thermal and light performance, such as (dimensions, locations orientation of building spaces and windows to wall area ratio). To reach a balancing point between them, for maximum reduction in cooling energy consumption in the summer, while keeping a comfortable level of natural lighting.” The research adopted an applied method to Revealed the parametric design mechanism To represent these characteristics as (parameters) to process and test them within three sequential process, (modeling, simulation and optimization), combined in one digital tool, uses algorithm to select the effective characteristics, that matching the resulted performance with specific criteria determined by the designer. The approach optimizes characteristics of three local housing pattern (Detached, Attached, and courtyard), within local environment, in order to achieve optimal efficient design. Ending with a set of conclusions about the importance and necessity of adopting this new approach within local architectural and environmental practices and studies.
Competitive advantage is a substantial strategic objective for organizations. It requires high levels in the quality of products and services provided to customers, continuous improvement of costing , care for creativity and innovative employees, and speed unique to the marketing and financial engineering, and business re-engineering processes. The situation in this area, requires actors to attract and develop human resources, including help in proper implementation of the strategic tasks that targeted by those institutions. According to the opinions and viewpoints of management scholars, the competitive advantage resource is the most important issue for organizations in the third millennium, which can be a
... Show MoreSloped solar chimney system is a solar chimney power plant with a sloped collector. Practically, the sloped collector can function as a chimney, then the chimney height can be reduced and the construction cost would be reduced.The continuity, Naver-stockes, energy and radiation transfer equations have been solved and carried out by Fluent software. The governing equations are solved for incompressible, 3-D, steady, turbulent standard model with Boussiuesq approximation to develop for the sloped solar chimney system in this study and evaluate the performance of solar chimney power plant in Baghdad city of Iraq numerically by Fluent (14) software with orking conditions such as solar radiation intensity (30
... Show MoreObjective: Many studies focused on clinical cases such as ovariohysterectomy of bitches and scarcely mentioned the histological features. The present study describes the cytoarchitecture characteristics of a local dog’s mature adult reproductive tract. Materials and Methods: Sixteen samples of uterus and cervix were obtained from local breed bitches to conduct this study. The organs were processed according to routine histopathological protocol and stained with hematoxylin and eosin, Masson’s trichrome, and combined Alcian blue (2.5 pH) and PAS (AB-PAS) stains. Results: The mature endometrium formed numerous short epithelial folds and epithelial crypts composed of mucous cells and cuboidal cells. The core of the endometrium is c
... Show MoreAbstract
The current research aims to know the reality of the research's coefficients, to know correlation and effectiveness between the organizational Agility and high performance . The current research has been applied on the official banks , including a sample of senior administration members (120) ; besides , the research has used questionnaire that being considered as the main tool for gathering information and data . It includes 59 questions in addition to the personal interviews program as to support the questionnaire and to fulfill a great deal of reality. It has been anal
... Show MoreThis research has been applied on 100 children (age 4 – 6 years) from three kindergartens distributed on basis of 43 children from the college of Education for women kindergarten (A) , 27 children from the governmental Al- Mustafa kindergarten (B) , and 30 children from the private Al – Baraom kindergarten (C) . Details concerning their school meals, already prepared at home , have been analyzed according to their dietary components taken from the tables of the dietary values .The statistical analysis results have shown no significant difference (p< 0.01) in the intake of energy , protein and thiamin between the children of A and C kindergartens while these children have significantly recieved higher amounts of the above nutrien
... Show MoreIn this study, a one-dimensional model represented by Butler-Volmer-Monod (BVM) model was proposed to compute the anode overpotential and current density in a mediator-less MFC system. The system was fueled with various organic loadings of real field petroleum refinery oily sludge to optimize the favorable organic loading for biomass to operate the suggested system. The increase in each organic loading showed higher resistance to electrons transport to the anode represented by ohmic loss. On the contrary, both activation and mass transfer losses exhibited a noticeable decrement upon the increased organic loadings. However, current density was improved throughout all increased loads achieving a maximum current density of 5.2 A/m3
... Show MoreObjective: This study aimed to assessing new suggested technique of Physical Growth Curves (PGC) charts in
children under two years old of a non-probability sample.
Methodology: A non-probability sample of size (420) children under two years selected from 12 Primary
Health Care Centers in Diyala governorate during the period from 15th Nov. 2010 to 13th Mar. 2011
according to admix of a different properties together in one chart/or growth curve chart included in at least
weight, Height, and Head circumference.
Results: the results showed different properties that can be admix together in one chart/or growth curve
chart included in at least weight, Height, and Head circumference. And to overtake the problem of the norm
Aim of the research is the study of improving the performance of the thermal station south Baghdad and the main reasons for reduced its efficiency. South Baghdad power planet comprises (6) steam turbine units and (18) gas turbine units .The gas turbine units are composed of two groups: the first group is made up of gas units (1,2), each of capacity (123) MW. The design efficiency of gas turbine units is 32%. The actual efficiency data of steam units is 18.3% instead of 45% which is the design efficiency. The main reason for efficiency reduction of gas units is the rejected thermal energy with the exhaust gases to atmosphere, that are (450-510) ℃.The bad type of fuel used (heavy) fuel. Another reason for the low efficiency and has a neg
... Show MoreDue to the developments taking place in the field of communications, informatics systems and knowledge management in the current century, and the obligations and burdens imposed on the business organization to keep pace with these developments, the traditional methods of administrative decision-making are no longer feasible, as recent trends have emerged in management that focus on the need to rely on quantitative methods such as operations research.. The latter is one of the results of World War II, which appeared for the first time in Britain to manage war operations. The first method used in this field is the linear programming method. The use of operations research has developed greatly in the past years, and the methods of analysis in
... Show MoreIn this work, effects of using different evaporative cooling pads (ECPs) on the energetic and exergetic efficiency of a direct evaporative air cooler (DEAC) have been theoretically and experimentally investigated. Three types of ECPs were used, i.e., honeycomb cellulose cooler pad (HCCP), shading-cloth cooler pad (SCCP), and aspen wood wool cooler pad (AWWCP). For SCCP and AWWCP, a 3-cm pad thickness was used, while for the HCCP, three different values of pad thickness were used, i.e., 3, 5, and 7 cm. Tests were carried out using air velocities of 8, 14, and 19 m/s, measured at the DEAC outlet. Engineering equation solver (EES) used for performing the required calculations of the various parameters affecting the thermal performance of the D
... Show More